                                                                                                     132008.1128.01

               40.    All internal roads shall be designed and constructed in accordance with Council’s
                      Planning Scheme Policy 5 – Engineering Design Standards – Roads, Drainage and
                      Earthworks. The roads shall be:
                         40.1.    Generally in accordance with drawing number ‘Masterplan’ prepared by RPS
                                  dated 18 October 2017, Plan Ref: 132938-01D,
                         40.2.    A minimum width of 5.5 metres, and
                         40.3.    Suitable for Council’s refuse collection vehicle to traverse through the site
               Car Parking
               41.    Carparking shall be provided within the sites generally as shown on drawings numbered
                      0673_DA_ADD_P47 “Masterplan/Carpark Layout” prepared by Smith + Tracey
                      Architects dated October 2008, 0673_DA13/P1 “Residential Aged Care – Basement”
                      prepared by Smith + Tracey Architects dated May 2008, 0673_DA22/P1 “Apartment
                      Buildings – Basement” prepared by Smith + Tracey Architects dated May 2008 and
                      within the “Independent Living Units” as shown the approved floor plans, except as
                      modified herein.
               42.    On road visitor spaces within the site shall be indented or staggered such that vehicle
                      movements and passing opportunities are not adversely affected.
               43.    Turning/manoeuvring areas shall be provided within each of the basement parking areas
                      of the “Apartment Buildings”.
               44.    One of the carspaces at the western end of the ground floor parking area of the
                      “Residential Aged Care” shown on drawing number 0673_DA11/P1 shall be dedicated
                      as a turning/manoeuvring area.
               45.    One of the carspaces at the eastern end of the basement parking area of the
                      “Residential Aged Care” shown on drawing number 0673_DA13/P1 shall be dedicated
                      as a turning/manoeuvring area.
               46.    The carparking areas shall be designed to comply with the provisions of AS/NZS 2890.1-
                      2004 (user Class 1A for Residential, Class 1 for Staff and Class 3 for Visitors), AS/NZS
                      2890.6:2009 (Disabled spaces) and AS 2890.2 (Commercial) with allowance for vehicles
                      to enter and leave the site in a forward gear and with a minimum head clearance
                      (headroom) at any point of 2.2m.
               47.    The required turning/manoeuvring areas shall be line-marked with chevrons and have
                      the words “No Parking” painted on the pavement. A sign shall also be provided to
                      indicate that the area is a “Turning Area Only” and that “No Parking is Permitted”.
               48.    All carparking shall be kept, maintained and line-marked in a condition fit for use.
               49.    All staff carpark spaces shall be clearly defined by line marking each space with the
                      words “Staff Parking Only” and by sign posting each space with a similar wording.
               Roof Water & Stormwater Drainage
               50.    Roof runoff from any new dwelling/building shall be directed to a rainwater storage
                      system or tank that is installed to ensure water from the rainwater storage system or tank
                      is used for external uses (such as watering gardens, irrigation, ornamental ponds, water
                      features, topping-up swimming pools, outdoor cleaning, etc) and for internal (ground
                      floor) use in washing machine cold taps and toilet cisterns. All rainwater tanks are to be
                      designed and installed in accordance with the Queensland Development Code (QDC)
                      current at the time of building approval, and shall be part of the plumbing application for
                      approval. The location and capacity of the tanks shall be clearly shown on the plans
                      submitted for Building Works / Operational Works approval and any overflow shall be
                      directed to the approved stormwater drainage system.

                                                                                                      Page 8 of 21


Document Set ID: 20451866
Version: 1, Version Date: 14/11/2017                                                               Print Date: 16 November 2017, 8:52 AM

Used in these records

About this file

File size
3.8 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Attachment A - Existing Approval.pdf · 3.8 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.