Council archive · source document
07/1087 - MCU - Entertainment & Dining Business Type 1 Food & Beverage [As Published] · 132007.1087
TOWN PLANNING REPORT
Specific Outcomes
Probable solutions
$2.2 Buildings and structures
{including swimming pools, sheds,
tennis courts and outbuildings) are
not constructed under overhead
electricity transmission lines, or within
fh
ken hicks
Proposal
electricity easements.
ano annaciatEy
314.18" Amenity sqnennesane: eqeesaeniaes |
electricity easements.
ORE"
Noise
O03 Development is designed and sited
fo avoid noise emissions that
unreasonably diminish the amenity of the
area or surrounding uses.
No solution provided
Complies.
The proposal is sited within a
designated industrial area and it is
considered that the café will not
unreasonably diminish the
amenity of the area or
surrounding uses.
Mechanical plant and equipment and
storage areas
O04 Mechanical plant and equipment
(including air conditioning equipment)
and storage areas are designed and
located to—
d) avoid adverse visual impacts when
viewed from the street and adjoining
properties; and
@) visually integrate with the building
design.
$4.1 Mechanical plant and
equipment are—
f) located more than 2m from any
property boundary;
where located at ground level,
screened by fencing 1.5m in
height or dense vegetation of at
least 1.5m in width incorporating
grouped trees and shrubs with
maximum separation distance of
Im measured from the centre of
the tree or scrub; and
are visually integrated into the line
and plane of the building and roof
design and do not project beyond
the height or width of the building
when viewed from the street and
adjoining properties;
AND
$4.2 For industrial business and Retail
business Type 3, materials stored
outside of a building do not exceed
4m in height or half the height of the
on-site buildings whichever is the
greater.
9
h
Complies.
This will be applied at detail
design,
Not applicable
Safety and security
O5 All property boundaries are clearly
identifiable with public and private
spaces clearly defined.
06 All premises and access routes are
clearly identifiable to all persons,
particularly emergency services
personnel.
07 All building entries are designed to
be obvious and easily identifiable.
55.1 Boundaries are identified by
such means as -
i) fencing; or
j) changes in surface materials or
levels; or
k) landscape treatments.
$6.1 All premises are identified by the
provision of the street number in a
prominent location, preferably near
the site entry, (i.e. on the kerb or
letterbox or by signage on the
building or site).
$7.1 The number of entrances and
exits are limited and main building
entrances/exits are located at the
front of the site, in view of the street.
Where this is not possible, due to site
or existing building constraints, a well
defined path is provided to the
entrance/exit; and
$7.2 Atl entrances/exits to buildings,
are lit and signed, and signage
includes hours of operation; and
$7.3 Entrances/exits are located to
provide a direct link to driveways and
Complies.
Boundaries are identified by the
utilisation of effective landscaping
treatments.
Complies.
This will be achieved.
Complies.
The main entrance to the café is
located near the front street to
improve legibility and access.
Complies.
This will be applied at detail
design
Complies.
This has been achieved within the
May 2007
Development Permit for Material Change of Use for Entertainment and Dinning Business Type 1
64 Gateway Drive, Noosaville
Page 17 of 22
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/1087 - MCU - Entertainment & Dining Business Type 1 Food & Beverage [As Published]Related documentApplication case desk ↗
About this file
- File size
- 3.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.