design group
D B
A B C WD.604 D E F WD.602 G H building design + interior design
5,000 1,660 5,890 1,660 3,700 8,990
1 Open pergola inside
side setback 1
1,390
1,390
1.5m SIDE SETBACK
ROOF BELOW
2 2m SIDE SETBACK 2m SIDE SETBACK
2
ROOF
C BELOW C
WD.603 WD.603
4,490
4,490
VERGOLA BELOW
DECK
BELOW
3 3
1 .5 m
ROOF
ROOF BELOW
SID
ROOF ROOF
E
2,425
2,425
SET
ROOF ROOF
BAC
BELOW BELOW ROOF
K
6.0M FRONT SETBACK
4 4
A ALFRESCO A
P.101 P.101
BELOW
E
WD.605
4,085
4,085
ROOF
BELOW
5 5
500
500
2m SIDE SETBACK
6 1.5m SIDE SETBACK
6
1,220
1,220
7 7
Roof/ wall inside
1.5m side setback
5,000 1,660 5,890 1,660 3,700 8,990
D B
A B C WD.604 D E F WD.602 G H
-
APPROVED PLANS MCU 3
issue
Material change of use (3)
issue / amendment
MCU18/0048 26.04.18 SF. LF. AB. NB.
ROOF PLAN NOOSA COUNCIL
issue date
client
drawn by
SCALE 1:100 @ A3 Cori & Andrew McGuinness
11 JUNE 2018 project
1801 McGuinness house
EXT. FINISHES LEGEND - location
7 Arakoon Cres Sunshine Beach Q 4567
GENERAL LEGEND FLOOR FINISH LEGEND WALL LEGEND AS aluminium screen. CS concrete slab. GS garage slab. SBJ silicone butt jointed glass.
TER
WIN ATH D04 denotes door number
ROOF PLAN
P FT1 FT2 Indicates extent of TILE RC masonry blockwork AL aluminium louvres, refer sched. DP down pipe. HWS hot water service. SP structural post, refer engineer.
SUN
m)
(7a
Lee Foster • director Scott Falconer • director
W04 denotes window number p - 0424 620 247 p - 0431 267 157
ng
ASD aluminium sliding door. DS driveway slab. HR handrail. SF structural footing, ref. eng.
si
e - [email protected] e - [email protected]
RC pool shell/off form concrete
Ri
design group
the aboda design group trust Level 2 1794 David Low Way Coolum Beach,
FFL 17.200 denotes finished floor level ABN 56 266 884 746 Q. 4573. PO box 2449 Noosa Heads Q 4567
Setting 5 pm C Indicates extent of CARPET AFD aluminium framed door. FCA fibre cement awning. LPG LPG gas bottle. TIM timber cladding. t/a aboda design group • BSA License -150580097 • www.aboda.com.au
N + RL 17.700 denotes spot level
90MM ext. timber frame
• This drawing is to be read in conjunction with engineers drawings & reports • Construction
ER H
Rising (6.30
am) AFW aluminium framed window. FC fibre cement ext. cladding. MR1 metal roof - (no refers to type). TD timber deck. to comply with all relevant SAA & NCC Codes & standard Bldg By-law 1975 & as amended •
MM AT 50 step 70MM int. timber frame
Copyright for design & drawings remain the property of the authors • Verify all dimensions on
SU N P denotes change in level TF TD Indicates extent of TIMBER. site prior to commencement of any works • These drawings are not to be used for scaling.
BA sun control battens, refer detail. FG fascia gutter. NGL natural ground line. TF timber floor.
m
SU
0p
Indicates extent of scale as shown @ A3 issue
5 .3
HATCHED AREA
HATCHED AREA
chs shs
i ng
NOT PART OF THIS denotes 'not part of structural posts - refer BAL1 balustrade-(no refers to type). FT1 floor tile (no refers to type). PF compliant pool fencing TFD timber framed door drawing no.
tt
Se
CONTRACT engineer.
GS DR Indicates extent CONCRETE
WD.204
this contract'
BLK masonry blockwork. fire fireplace PW parapet wall. VER vergola. MCU 3
C carpet flue flue kit PV photovoltaic cells.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
SUPERSEDED - MCU18 0048 - Decision Notice.pdfRelated documentApplication case desk ↗
About this file
- File size
- 5.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.