Appendix A - Proposal Plans
Attached to the e-mail MCU15/0023 Development Application (Email 1 of 2).
Plans and drawings: the text below has words only, no drawings.
Very large file (12.1 MB): may take a few minutes to open.
Original PDF page 15, section 1. The text section number identifies this passage in the reader.
'C’ BARS 250mm THICK MAX 12m LENGTH x 2.7m WIDTH $12-200 NX . — oc PROPOSED WATER LEVEL WALLS $12-300 BAR BEAM STEEL RIVTM4 TOP AND BOTTOM NOTE: - 1, LAP TM A MIN 500mm 2. COVER TO ALL BEAM STEEL - 50mm 3. TIE TM WITH R6 LIGS AT 500mm CRS 4. AN EQUIVALENT CAGE CAN BE USED IN LIEU OF THE TM SPECIFIED. € & Ss S » nw S12-300 BAR ( POOL STEEL REINFORCEMENT > MARK DESCRIPTION STEEL LONGITUDINAL FLOOR é& END A BARS Soa Spars 512-300 € ACROSS FLOOR & 5 B BARS SIDE VERTICAL BARS S12-300 s s C BARS ARONA $12-200 z \ JS L °n’ BARS N12—400 STARTER BARS TO LAP S12-300 A MIN 600mm WITH BASE SLAB REINFORCEMENT. 'B’ BARS $12-300 MAX 1500mm * $12-100 BARS FOR THE Ge FIRST THREE BARS FROM TOP OF WALL 200mm _ THICK WALLS S12-300 BARS + S12-300 INTERMEDIATE BARS Zz CRE MES SSPSs SCREW-IN PIERS NOTE: - 7.5 TONNE (ULTIMATE LOAD) STEEL SCREW-IN PIERS WITH 1/N12 BAR - 200mm LONG THROUGH TOP OF FOOTING 0.75mm BONDEK WITH PROFILE SPANNING ACROSS SHORT SIDE OF POOL. (B2 EXPOSURE, 40MPa CONCRETE, MAX 2700mm SPAN). FOOTING BEAMS TO FULL PERIMETER OF POOL PROMDE 100mm COVER TO BOTTOM OF FOOTING TYPICAL POOL CROSS-SECTION SECTION Scale 1:20 “— 250mm THICK BASE NOTE: CONTACT THIS OFFICE IF WALL HEIGHT EXCEEDS 3000mm MAX 3000mm 200 SERIES BLOCK WALLS REINFORCED WITH N12 VERTICAL & HORIZONTAL BARS AT 1000mm CENTRES. TO LAP A MIN 600mm WITH BLOCK WALL REINFORCEMENT. SS LR YQ SS YY YZ LORI KK KKK VR ORR xR Ww RR SS wy . 2 LN, KX RE VRAIS, SEIKI ON | 450mm SCREW-IN PIERS NOTE: - 7.5 TONNE (ULTIMATE LOAD) STEEL SCREW-IN PIERS WH 1/N12 BAR - 200mm LONG THROUGH TOP OF FOOTING PROVIDE 100mm COVER TO BOTTOM OF FOOTING General Notes 1. DO NOT SCALE DRAWINGS. 2. IF ANY DIMENSIONS ARE SHOWN ON THIS DRAWING, THEY ARE TO BE CONFIRMED WITH THE BUILDER PRIOR TO PROJECT COMMENCEMENT. 3. ENSURE THE BUILDING PLATFORM IS PROOF ROLLED TO OBTAIN A FIRM FOUNDATION BASE TO SUPPORT THE SLAB AND FOOTING LOADS. ALL FOOTINGS ARE TO BE DEEPENED THROUGH ANY SOFT SPOTS TO BEAR INTO NATURAL GROUND, OR CERTIFIED COMPACTED FILL MATERIAL, A MIN 300mm. 4, CONCRETE SLAB DETAILS: — a. MINIMUM THICKNESS = 100mm b. REINFORCEMENT = SL82 MESH TO COMPLY WITH AS1304, SUPPORTED ON BAR CHAIRS SPACED ON A MAXIMUM 800mm GRID. c. WATERPROOF MEMBRANE = MIN 0.2mm THICK POLYTHENE PLACED UNDER THE SLAB AREA WITH ALL PENETRATIONS TO BE SEALED WITH TAPE OR ANOTHER APPROVED METHOD. d. CONCRETE — N20 AFTER 28 DAYS WITH A NOMINAL AGGREGATE SIZE OF 20mm. THE SLUMP SHOULD BE NO MORE THAN 100mm. ALL CONCRETE PLACED IS TO BE VIBRATED TO REMOVE ENTRAPPED AIR. 5. TERMITE PROTECTION: - THIS BUILDING IS TO BE PROTECTED FROM SUB-TERRANEAN TERMITES IN ACCORDANCE WITH THE BUILDING CODE OF AUSTRALIA AND THE RELEVANT AUSTRALIAN STANDARD. 6. THE FINISHED GROUND LEVEL IS TO BE SLOPED SUCH THAT WATER IS NOT ALLOWED TO POND NEAR THE FOUNDATIONS. A POSITIVE GRADIENT IS TO BE MAINTAINED ACROSS THE BUILDING AREA. N12-400 WALL STARTER BARS PB PRELIMINARY 25.03.15 PA PRELIMINARY 27.01.15 ISSUE REVISION /ISSUE DATE J a. CONSULTIN INCORPORATING Geo Structural & Geo Investigations Ph: 5351 1011 or 5351 1555 Fax: 5351 1044 19/25 Quanda Road, Coolum Beach QLD 4573 Email: [email protected] EES (CLIENT: R. MEAD / C. BASTOCK PROVECT: Proposed Residence at 44 Seaview Terrace Sunshine Beach QLD 4567 Drawn by Designed by [one Mar. 2015 TW. SB. ‘Seale Certified by NIS. S.Brimelow RPEQ(4942) vob Number "4-02 $8492 FOUNDATIONS PB Ne
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.