Council archive · source document
20200903OBA_R1_Loading_Dock_Operational_Conditions · OPW20/0145
MATTHEW PALAVIDIS
VICTOR FATTORETTO
MATTHEW SHIELDS
20191414.2/0309A/R1/OB
3/09/2020
Stockwell Development Group Pty Ltd
399 Montague Road
WEST END QLD 4101
Attn: Harrison Hurst
Noosa Civic - Loading Dock Operational Conditions
This letter addresses the following recent clarifications regarding loading dock operating times and
conditions for Noosa Civic:
a) The loading times are between 3am and 10 pm.
b) Refrigeration trucks would need to idle whilst loading/unloading due to food safety requirements
We note the following:
Loading Times
The previous assessment and analysis in the acoustic report prepared by ALC (revision 2, ref:
20191414.2/2708A/R2/OB, dated 27/08/2020) took into consideration day, evening and night time loading
activities (i.e. 5am to 7am for night time, and 7am to 10pm for day and evening). Given that night time noise
impacts were assessed already and the additional hours of 3am to 5am fall in the same period, no changes
to the acoustic assessment is required.
Refrigeration Truck Idling
Due to food safety requirements, refrigeration trucks must remain idling whilst they are being
loaded/unloaded. An impact assessment of the idling has been included in the revised report, with
assumptions and predicted incident noise levels in Section 5 of the attached revised acoustic report.
Recommendations to address the impacts from idling refrigeration truck have also been updated.
A revised acoustic report addressing these issues above has been attached in the Appendix of this letter and
includes updated acoustic treatment and management recommendations based on the revised operational
requirements.
BRISBANE ABN 11 068 954 343
Level 1 www.acousticlogic.com.au
82 Arthur Street
FORTITUDE VALLEY QLD 4006
(07) 3211 5591
The information in this document is the property of Acoustic Logic Consultancy Pty Ltd 11 068 954 343 and shall be returned on
demand. It is issued on the condition that, except with our written permission, it must not be reproduced, copied or communicated
to any other party nor be used for any purpose other than that stated in particular enquiry, order or contract with which it is issued.
I:\Jobs\2019\20191414\20191414.2\20200903OBA_R1_Loading_Dock_Operational_Conditions.docx 1
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 30 pages
Page 2
We trust this information is satisfactory. Please contact us should you have any further queries. Yours faithfully, Acoustic Logic Consultancy Pty Ltd Omar Busaidi I:\Jobs\2019\20191414\20191414.2\20200903OBA_R1_Loading_Dock_Operational_Conditions.docx 2
Page 3
APPENDIX A – UPDATED ACOUSTIC REPORT (REVISION 4) I:\Jobs\2019\20191414\20191414.2\20200903OBA_R1_Loading_Dock_Operational_Conditions.docx 3
Page 4
poe oe wera LOG iC MATTHEW SHIELDS Noosa Civic Noise Impact Assessment BRISBANE ABN 11 068 954 343 Level 1 www.acousticlogic.com.au 82 Arthur Street FORTITUDE VALLEY QLD 4006 (07) 3211 5591 The information in this document is the property of Acoustic Logic Consultancy Pty Ltd 11 068 954 343 and shall be returned on demand. It is issued on the condition that, except with our written permission, it must not be reproduced, copied or communicated to any other party nor be used for any purpose other than that stated in particular enquiry, order or contract with which it is issued. I\Jobs\2019\20191414\20191414.2\202009030BA_R4_Noise_Impact_Assessment.docx 1
Page 5
Project ID 20191414.2 Document Title Noise Impact Assessment Attention To Stockwell Development Group Pty Ltd Revision Date Document Reference Prepared By | Checked By | Approved By 0 24/07/2020 | 20191414.2/2407A/RO/OB OB 1 26/08/2020 | 20191414.2/2608A/R1/OB OB TS 2 27/08/2020 | 20191414.2/2708A/R2/OB OB OB 3 2/09/2020 | 20191414.2/0209A/R3/OB OB TS 4 3/09/2020 | 20191414.2/0309A/R4/OB OB OB I\Mobs\2019\20191414\20191414.2\202009030BA_R4_Noise_Impact_Assessment.docx
Page 6
TABLE OF CONTENTS INTRODUCTION. ............csccsscssccssssssssssssssssssesssscsssssssssssssssssesssecssssssssessesssessssseesoessessessonssees 4 SITE DESCRIPTION... NOISE TARGETS NOISE MEASUREMENTS. 4.1 MEASUREMENT LOCATIONS.. 4.2 MEASURED NOISE LEVELS 4.2.1 Unattended Measurements Results 4.2.2 Attended Measurement Results... 5 NOISE SOURCES/IMPACTS...... 5.1 LOADING DOCKS.... 5.1.1 Trolley Collection 5.1.2 Delivery Trucks. 5.1.3 Mechanical Plant 5.1.4 Compactor. 5.2 NOISE CALCULATION... 6 RECOMMENDATIONS 6.1 MANAGEMENT CONTROLS .... 6.2 ACOUSTIC BARRIER. 6.3. RESIDENTIAL BUILDINGS FACADE CONSTRUCTION 6.4 MECHANICAL PLANT NOISE LEVELS o 7 CONCLUSION... cee ceccssceesssscsessscssssscsssssesssscsessssssssssssssssssssscsssssscssssssssessessessosssssossoess RhWN = I\Mobs\2019\20191414\20191414.2\202009030BA_R4_Noise_Impact_Assessment.docx 3
Page 7
1 INTRODUCTION Acoustic Logic consultancy (ALC) have been engaged to conduct an assessment of major noise source impacts from the Noosa Civic Shopping Centre onto proposed adjacent residential development. The report is in response to the Council’s request: 1. Prepare and submit to Council for approval with and Operational Works application a revised acoustic report which includes measures to mitigate noise generated from the shopping centre operations and equipment, including deliveries, truck movements and rubbish collection. This report should consider attenuation at the noise source as well as a noise barrier along the shared boundary of Lots 19 and 217. All measures to mitigate noise must be implemented prior the submission of the subdivision plan to Council. Noise attenuation is required to achieve the following acoustic quality for potential residential uses on Lots 17-19. The measurement location must include receivers being places at the closest point to the future residential and office buildings. Criteria (measured at the receptor) dB(A) Sensitive receptor Time of Day LAeq.adj, Thr? LAT adj, Th Daytime and evening (habitable spaces) 35 e Dwelling (indoors) Night-time (sleeping areas) 30 40 "Acoustic descriptor/noise target for continuous noise sources (eg. Mechanical plant). “Acoustic descriptor/noise target for transient impacts arising from loading dock activities (e.g. truck movements, reversing alarms, compactor, trolley etc.) The purpose of this assessment is the following: Establish the predicted intrusive noise levels at the proposed subdivision site on Hofmann Road for lots 17-21. Provide acoustic attenuation recommendations to meet the indoor acoustic criteria set by Noosa Shire Council. These are applied at the source, boundary, and receiver. This report includes attended and unattended noise measurements from the previous ALC acoustic report (ref: 20191414.1/1501A/R2/SS, dated 15/01/2020). I\Mobs\2019\20191414\20191414.2\202009030BA_R4_Noise_Impact_Assessment.docx 4
Page 8
2 SITE DESCRIPTION The site comprising the proposed lots 17, 18, 19, and 21 is bound by the following: e North, North-east - Noosa Civic Shopping Precinct e¢ West — Commercial precinct e South - Townhouses across Hofmann Drive. The loading docks are indicated in Figure 1 below. Site (Lots 17,18,19,21) Noosa Civic Loading Docks Figure 1 — Site Location I\Mobs\2019\20191414\20191414.2\202009030BA_R4_Noise_Impact_Assessment.docx 5
Page 9
3 NOISE TARGETS In accordance to the Information Request, Noosa Shire Council has requested that the development be assessed in accordance with the criteria below. Table 1 - EPP Noise 2008, Schedule 1 - Acoustic Quality Objectives for Residential Sensitive Time of Day Criteria (measured at the receptor) receptor dB(A) Laeq.adj,thr’ Latadj, thr” daytime and evening 35 45 dwelling (indoors) (habitable spaces) night-time (sleeping areas) 30 40 ' Acoustic descriptor/noise target for continuous noise sources (e.g. mechanical plant). 2 Acoustic descriptor/noise target for transient impacts arising from loading dock activities (e.g. truck movements, reversing alarms, compactor, trolley etc.). I\Mobs\2019\20191414\20191414.2\202009030BA_R4_Noise_Impact_Assessment.docx 6
Page 10
4 NOISE MEASUREMENTS Measured noise levels are obtained from the previous ALC acoustic report (ref: 20191414.1/1501A/R2/SS, dated 15/01/2020) and are presented below. 4.1 MEASUREMENT LOCATIONS Monitor locations were selected upon accessibility and accuracy in considering ambient conditions whilst capturing dominant noise sources around site. Unattended ® Attended Figure 2- Noise Measurement Locations I\Mobs\2019\20191414\20191414.2\202009030BA_R4_Noise_Impact_Assessment.docx 7
Page 11
4.2 MEASURED NOISE LEVELS 4.2.1 Unattended Measurements Results Table 2 -NGARA Measurement Summary Date Average Acoustic Descriptor, dB(A) Leq Loo Lio Li D* E* N* D* E* N* D* E* | N* | D* E* N* 20/11/19 59 48 48 57 45 42 60 50 50 61 53 53 21/11/19 57 52 50 55 50 45 59 54 51 61 56 54 22/11/19 58 48 48 56 44 43 59 50 | 49 61 53 53 23/11/19 58 | 52 | 48 56 46 43 59 | 54 | 49 | 60 | 56 | 53 24/11/19 58 45 49 56 42 43 59 | 46 50 60 | 48 54 25/11/19 59 | 49 | 50 57 45 46 | 60 | 50 | 51 | 62 | 53 | 54 26/11/19 59 48 48 57 46 44 60 50 50 62 52 54 27/11/19 59 57 61 63 AVERAGE 58 49 49 56 45 44 60 | 50 | 50 | 61 53 54 * D- Day (7:00-18:00), E- Evening (18:00 — 22:00), N-Night (22:00-7:00) I\Mobs\2019\20191414\20191414.2\202009030BA_R4_Noise_Impact_Assessment.docx
Page 12
Table 3 -Rion NL42 Measurement Summary Date Average Acoustic Descriptor, dB(A) Leq Loo Lio Li D* E* N* D* E* N* D* E* N* D* E* N* 20/11/19 54 48 44 51 46 37 56 50 | 46 66 56 59 21/11/19 52 | 49 | 44 49 46 36 | 53 | 50 | 46 | 66 | 59 | 61 22/11/19 52 49 44 49 46 36 53 50 | 45 66 | 60 61 23/11/19 52 48 44 49 46 35 54 | 49 | 46 66 58 60 24/11/19 53 | 48 | 43 49 45 36 | 56 | 50 | 45 | 67 | 58 | 61 25/11/19 52 49 43 49 46 37 54 51 45 66 | 61 61 26/11/19 57 51 44 52 47 37 59 54 | 46 70 59 60 27/11/19 54 51 56 67 AVERAGE 53 49 44 50 46 36 55 51 46 | 67 | 59 | 60 * D- Day (7:00-18:00), E- Evening (18:00 — 22:00), N-Night (22:00-7:00) 4.2.2 Attended Measurement Results Table 4 -Loading Dock Activity, Attended Measurements Location’ Noise Source Acoustic Descriptor, dB(A) Leq Lax Lpeak 1 Mechanical plant @ 25 57 62 78 metres 2 Reversing signal from trolley 69 76 83 collection truck 3 Mechanical plant noise 71 73 85 through exhaust/grille @ 1 metre away ' Refer to Figure 2 for location on map. I\Mobs\2019\20191414\20191414.2\202009030BA_R4_Noise_Impact_Assessment.docx
Page 13
5 NOISE SOURCES/IMPACTS The following sections outline current major noise sources that were identified upon the previous site visit to have potential impact on site. 5.1 LOADING DOCKS 5.1.1 Trolley Collection During time on site, it was observed that trolley activity is a regular occurrence across both loading docks. Noise level that was measured in relation to noise produced by trolley activity was 69 dB(A) Leg. Trolley collections is understood to only occur during day and evening periods (i.e. 7am to 10pm) which is also considered in this assessment. 5.1.2 Delivery Trucks It was observed that small to medium sized delivery trucks were present within the loading docks during time of site visit with no more than 1 truck in each hour at the loading docks. As advised by the client, we note that the loading dock operational hours start at 3am and can run up to 10pm. Truck (incl. refrigeration truck) idling was only assumed to occur in the loading dock during nominal 15minute loading period, and not along the boundaries or at the entrance to the loading docks. Where trucks enter the site to wait for loading and generally during loading (unless short-time drop-off/pick-up), engines must be turned off and in case of refrigeration trucks, these should just come in and leave site after loading as no idling would be allowed at other times. Such restrictions should be included if not yet followed (e.g. signs installed at the entry and along the boundaries and within the shopping centre loading docks). 5.1.3. Mechanical Plant The following mechanical plant was observed and noted in Figure 2. e Eastern Loading Dock Plant deck above loading dock ‘5’ emitting a calculated sound power level of 93dB(A). e Kitchen exhaust sound power level of 99dB(A). e Western Loading Dock - Plant room/exhaust adjacent loading dock ‘2’ were measured and calculated to have a sound power level 90 dB(A). Other plant is generally located on the rooftop of the shopping centre and therefore, providing significant noise shielding. In any case, the assessment is based on a sound power level of 90dB(A) At night, our predictions are based on kitchen exhaust fan being turned off together with other plant adjacent to loading docks. No other mechanical plant was considered and located during site inspections. In case of additional other plant, these must operate to ensure that the Loo background noise levels at the future residential buildings are not exceeded. 5.1.4 Compactor A compactor was noticed located by the ‘Big W’ loading dock 3 with an assumed Lmax Sound power level of 100 dB(A). Compactor operation has been excluded from night time assessments as it should only operate between the hours of 7am and 6pm. I\Mobs\2019\20191414\20191414.2\202009030BA_R4_Noise_Impact_Assessment.docx 10
Page 14
5.2 NOISE CALCULATION Measured noise levels and mechanical plant noise data and operational conditions highlighted in the previous section have been used to calculate the predicted intrusive noise levels at the sensitive noise receptors (lots 17, 18, 19, and 21) based on the expected building layouts of the Lots as described below and indicated in the figures below. A SoundPLAN™ computer model was developed for these noise sources as described activities and used to predict noise emissions from the compactor and loading docks to the sensitive receptors (lots 17, 18, 19, and 21). Predictions were made for the following scenarios: e Allloading docks and compactor operating concurrently, representing the worst-case scenario for day time noise emissions. e All loading docks operating concurrently, representing the worst-case scenario for evening and night time noise emissions as per the description in Section 5.1; e Only the compactor operating within the hours nominated and assumed. e Mechanical plant operational scenarios as described in this report. The analysis was conducted based on the following assumptions: e Mechanical plant decks indicated in Figure 2 have a sound power level of 90 dB(A) Leg each. e Kitchen exhaust fan indicated in Figure 2 has a sound power level of 99dB(A) Lea; ¢ Loading dock trucks have a sound power level of 101 dB(A) Linax. e Refrigeration trucks were assumed to idle for 15 minutes whilst unloading, with a sound power level of 95dB(A) Leq at a height of 3m above the ground level. This idling was only assumed to occur in the loading dock, and not along the boundaries or at the entrance to the loading docks. The refrigeration trucks, therefore, must not enter the site prior to loading to wait for their turn. Such restrictions should be included if not yet followed (e.g. signs installed at the entry and along the boundaries of the shopping centre loading docks). ¢ For all other trucks, no idling was assumed within the sites within short term drop-off/pick-up occurring at the loading docks only (less than 10minutes) and such restrictions should be included if not yet followed (e.g. signs installed at the entry and along the boundaries of the shopping centre loading docks). ¢ Compactor indicated in Figure 2 has a sound power level of 100dB(A) Linax. e Kitchen exhaust fans being turned off between 10pm and 7am and other plant adjacent and within loading docks not operational after 10pm and prior to 7am. ¢ Compactor is not operational between 6pm and 7am; « No trolley collection between 10pm and 7am. e The presence of a 6m wide plantation buffer between the northern boundary of the residential lots and the shopping centre paved loading dock and entry boundary. e Facade line of proposed residential development approximately 8 metres from loading dock boundary (refer to the closest sensitive receiver buildings used in calculations indicated in figure below) I\Mobs\2019\20191414\20191414.2\202009030BA_R4_Noise_Impact_Assessment.docx 11
Page 15
Assumed receiver building locations for Lots 17,18,19 and 21. ¢ Assessed habitable space taken as a typical bedroom with a floor area of 11m, and volume of 27m. * Typical fagade/glazing area of typical bedroom - 7.7m’, with the assumed typical layout presented below ¢ Assessed typical living room with a floor area of 20m?, and volume of 50m? with total fagade glazing area 8m’, with the assumed typical layout presented below; ¢ 1.8m high acoustic barrier along the boundary of lots 19, and 21 as indicated in Section 6. Other configurations and activities/plant must be re-assessed during detailed design review of the residential development to ensure that indoor noise limits can be achieved. I\Mobs\2019\20191414\20191414.2\202009030BA_R4_Noise_Impact_Assessment.docx 12
Page 16
Glazing 2.1m x 1.5m
Glazing 3.0m x 0.5m Glazing 3.0m x 0.5m
DD
Balcony Balcony
Bedroom
Bedroom
Glazing 3.0m x 1.2m
Glazing 3.0m x 1.2m
Living Room Living Room
Unit 1 Unit 2
eee= Facade Wall
== = internal Partition Wall
Figure 3- Assumed Typical Unit Layout
Figure 4 to Figure 6 present the SoundPLAN™ model of the day time period emissions for all loading docks
and the compactor operating concurrently. To assess compliance against the Laz,aqj1nr Noise criteria for the
worst-case conditions, the model presents the Lmax dB(A) noise levels. The model includes the existing 1.0m
high wall in the loading area, as well as the proposed 1.8m high acoustic barrier along the boundary of the
sensitive receivers (lots 19, and 21 as indicated in Section 6).
I\Mobs\2019\20191414\20191414.2\202009030BA_R4_Noise_Impact_Assessment.docx 13
Page 17
Noosa Civic Shopping Centre Loading dock barrier (1000mm) Residential barrier (1800mm) Loading dock Lmax 101 dB(A) SWL ‘Compactor Lmax 100 dB(A) SWL Ground Level 4.8m above building pad level Prepared by: 08 Date: 28/07/2020 Noise Level Signs and symbols Linax Line source Be [ZZ won batons wal acousTe Figure 4- SoundPLAN™ Day Time Modelling of All Loading Docks and Compactor — Ground Level NN Noosa Civic Shopping Centre Loading dock barrier (1000mm) Residential barrier (1800mm) Loading dock Lmax 101 dB(A) SWL ‘Compactor Lmax 100 dB(A) SWL Level 1 4.8m above building pad level Prepared by: 08 Date: 28/07/2020 Noise Level Signs and symbols acousTe Figure 5- SoundPLAN™ Day Time Modelling of All Loading Docks and Compactor — Level 1 I\Mobs\2019\20191414\20191414.2\202009030BA_R4_Noise_Impact_Assessment.docx 14
Page 18
Noosa Civic Shopping Centre Loading dock barrier (1000mm) Residential barrier (1800mm) Loading dock Lmax 101 dB(A) SWL ‘Compactor Lmax 100 dB(A) SWL Level 2 7.8m above building pad level Prepared by: 08 Date: 28/07/2020 Noise Level Signs and symbols Line source Lax aS mm - «4 iain builcing © Dy man outone wal acousTe Figure 6- SoundPLAN™ Day Time Modelling of All Loading Docks and Compactor — Level 2 I\Mobs\2019\20191414\20191414.2\202009030BA_R4_Noise_Impact_Assessment.docx 15
Page 19
Figure 7 to Figure 9 present the SoundPLAN™ model of the evening/night time period emissions for all loading docks operating (note: loading dock not operational after 10pm and before 3am). Sr Noosa Civic Shopping Centre Loading dock barrier (100mm) Residential barrier (1800mm| Loading dock Lmax 101 dB(A) SWL Ground Level 4.8m above building pad level Prepared by: 08 Date: 26/07/2020 Noise Level Signs and symbols ne source = ‘Main buitsing SB. : 4 8 Wai <x ACOUSTIONS Figure 7- SoundPLAN™ Evening/Night Time Modelling of Loading Docks Only - Ground Level ~ Noosa Civic Shopping Centre Loading dock barrier (100mm) Residential barrier (1800mm| Loading dock Lmax 101 dB(A) SWL Level 1 4.8m above building pad level Prepared by: 08 Date: 26/07/2020 Noise Level Signs and symbols © Man uli 3 2 wal <x ACOUSTIONS Figure 8- SoundPLAN™ Evening/Night Time Modelling of Loading Docks Only - Level 1 I\Mobs\2019\20191414\20191414.2\202009030BA_R4_Noise_Impact_Assessment.docx 16
Page 20
Noosa Civic
Shopping Centre
Loading dock barrier (100mm)
Residential barrier (1800mm|
Loading dock Lmax 101 dB(A) SWL
Level 2
7.8m above building pad level
Prepared by: 08
Date: 26/07/2020
Noise Level Signs and symbols
ne source
Lmax
naa oie source
= ‘Main buitsing
SB. : 4 8
Wai
x ACOUSTIONS
Figure 9- SoundPLAN™ Evening/Night Time Modelling of Loading Docks Only — Level 2
Figure 10 to Figure 12 present the SoundPLAN™ model of the day time period emissions for only the
compactor operating.
Noosa Civic
Shopping Centre
Loading dock barrier (1000mm)
Residential barrier (1800mm)
Compactor Lmax 100 dB(A) SWL
Ground Level
1.8m above building pad level
Prepared by. OB
Date: 28/07/2020
Noise Level Signs an
L
max
ingsay
mm
Go - 3
8. 48
6 49
49-52
ACOUSTICNG
Figure 10- SoundPLAN™ Day Time Modelling of Compactor Only - Ground Level
I\Mobs\2019\20191414\20191414.2\202009030BA_R4_Noise_Impact_Assessment.docx 17
Page 21
Noosa Civic Shopping Centre Loading dock barrier (1000mm) Residential barrier (1800mm) Compactor Lmax 100 dB(A) SWL Level 1 4.8m above building pad level Prepared by. OB Date: 28/07/2020 Noise Level Signs and symbols Une source max ingsay mm Go - 3 8. 48 6 49 49-52 Gi 2 - 55 ACOUSTICNG Figure 11- SoundPLAN™ Day Time Modelling of Compactor Only — Level 1 Noosa Civic Shopping Centre Loading dock barrier (1000mm) Residential barrier (1800mm) Compactor Lmax 100 dB(A) SWL Level 2 7.8m above building pad level Prepared by: OB Dato: 28/07/2020 Noise Level Signs and symbols L, —— Une source ingsiA) Point source mm Main buildin ms J s Walt ACOUSTICNG Figure 12- SoundPLAN™ Day and Evening Time Modelling of Compactor Only — Level 2 I\Mobs\2019\20191414\20191414.2\202009030BA_R4_Noise_Impact_Assessment.docx 18
Page 22
Figure 13 and Figure 14 present the SoundPLAN™ model mechanical plant day and evening time period
emissions.
Noosa Civic
Shopping Centre
Loading dock barrier (1000mm)
Residential barrier (1800mm)
Propared by: OB
Date: 26/08/2020
Noise Level Signs and symbols
4 LAeq — wall
{ in dBA)
mmm <0
Mo 3
43-48
4%. 49
49 - 52
AcOUSTICNG
Figure 13- SoundPLAN™ Day and Evening Time Modelling of Mechanical Plant — Lots 17 and 18
I\Mobs\2019\20191414\20191414.2\202009030BA_R4_Noise_Impact_Assessment.docx
Noosa Civic
Shopping Centre
Loading dock barrier (1000mm)
Residential barrier (1800mm)
Propared by: OB
Date: 2608/2020
Noise Level Signs and symbols
LAeq — wal
naa)
mmm
MB wo - 3
43 - 48
4%. 49
lm «9 - 52
ACOUSTICN
19
Page 23
Figure 14- SoundPLAN™ Day and Evening Time Modelling of Mechanical Plant - Lots 17, 18 and 19
Noosa Civic
Shopping Centre
Loading dock barrier (1000mm)
Residential barrier (1800mm)
Propared by: OB
Date: 2608/2020
Noise Level Signs and symbols
LA — wal
ncaa)
=
MB wo - 3
43 - 48
4%. 49
=
ACOUSTICN
Figure 15- SoundPLAN™ Day and Evening Time Modelling of Mechanical Plant - Lot 21
I\Mobs\2019\20191414\20191414.2\202009030BA_R4_Noise_Impact_Assessment.docx 20
Page 24
Figure 16 to Figure 18 present the SoundPLAN™ model mechanical plant night time period emissions (note: kitchen exhaust and any mechanical plant adjacent to loading docks or any other major plant turned off). Noosa Civic Shopping Centre Loading dock barrier (1000mm) Residential barrier (1800mm) Source Noise Levels LAeq SWL Chiller Plant 85 dB(A) Ground Level 4.8m above building pad level Prepared by: OB Date: 2807/2020 Noise Level Signs and symbols Une source inca) £ Point source [Z Win bung Walt Point receiver Figure 16- SoundPLAN™ Night Time Modelling of Mechanical Plant - Ground Level I\Mobs\2019\20191414\20191414.2\202009030BA_R4_Noise_Impact_Assessment.docx 21
Page 25
Noosa Civic Shopping Centre Loading dock barrier (1000mm) Residential barrier (1800mm) Source Noise Levels LAeq SWL Chiller Plant 85 dB(A) Level 1 4.8m above building pad level Prepared by: OB Date: 2807/2020 Noise Level Signs and symbols seuereasesss acoustic We LOG Figure 17- SoundPLAN™ Night Time Modelling of Mechanical Plant - Level 1 ~ | Noosa Civic Shopping Centre Loading dock barrier (1000mm) Residential barrier (1800mm) Source Noise Levels LAeq SWL Chiller Plant 85 dB(A) Level 2 7.8m above building pad level Prepared by: OB Date: 2807/2020 Noise Level Signs and symbols seuereasesss acoustic We LOG Figure 18- SoundPLAN™ Night Time Modelling of Mechanical Plant — Level 2 I\Mobs\2019\20191414\20191414.2\202009030BA_R4_Noise_Impact_Assessment.docx 22
Page 26
Table 5 - Predicted Shopping Centre Noise Impacts at the Proposed Residential Lots Receiver’ Time Predicted Incident Noise Level at Facade Internal Acoustic dB(A) Noise Level | Treatment Criteria Required . Compact. | Mech. Loading Docks La? Plant? dB(A) to Achieve Laeq Indoor La Laeq Noise Limit* Day 28 52 45 Latad,thr Evenin 35 Laeqadj.th Lot v Ground ig 57 AG eq,adj,1hr Type A eve . N/A 40 Latadjthr Night 4 30 Lpeg,adj,1hr Day 28 56 45 Latad,thr Evening 35 Laeguadj,thr Lot 17 Level 1 60 50 Type B Night N/A 4s AO Latadjthr 30 Lheg,adj.thr Day 29 45 Latad,thr 57 Evening 61 35 Laeg,adj,thr Lot 17 Level 2 53 Type B N/A 40L, 1 Night 48 Atadiin 30 Lheq,adj.thr Day 37 45 Lat,adjhr Acoustic Evening >! 35 Laeqadj,thr Seals to Lot 18 Ground 46 32 windows, level ; N/A AO Laradthe Non glazed Night 43 wall to Type 30 Lpcg,adj,thr A Day 37 57 45 Latad,thr Evening 35 Laeqadj,thr Lot 18 Level 1 47 39 Type A Night N/A 4s 40 Lat ad, thr 30 Laeg,adj,thr Day 41 57 45 Lat adj thr Evening 35 Laeq,adj.thr Lot 18 Level 2 51 45 Type A . N/A 40 Latadjthr Night 46 30 Laeg,adj,thr Day 55 53 45 Latad)thr Evenin N/A 35 Laeguadj.th Lot 19 Ground g 59 48 / eq.adj Ahr Type B level 40 Latadjthr Night 39 30 Leg,adj,thr Lot 19 Level 1 Day 61 49 63 56 45 Lat,adjthr Type B I\Mobs\2019\20191414\20191414.2\202009030BA_R4_Noise_Impact_Assessment.docx 23
Page 27
| . Predicted Incident Noise Level at Facade Internal Acoustic Receiver Time . dB(A) Noise Level | Treatment Loading Dock Compact. | Mech. Criteria Required oadiing Nock La? Plant? dB(A) to Achieve Laeq Indoor Lat Laeq Noise Limit* Evening 35 Laeqadj,thr N/A 40 L, Night 4A A1,adj, Thr 30 Lheg,adj,thr Day 63 56 45 Latad,thr Evening 35 Laeqadj,thr Lot 19 Level 2 62 49 Type B N/A 40 L, Night A5 A1,adj,1hr 30 Laeg,adj,thr Day 64 58 45 Latad,thr Lot 21 Ground | Evening 35 Lacq,adj.thr level 66 53 N/A WO lesan Type C Night 38 a 30 Laeg,adj,thr Day 69 61 45 Lat,adjthr Evening 35 Laeqadi,thr Lot 21 level 1 70 58 Type C Night N/A 4s 40 Latadjthr 30 Lieq,adj,thr Day 69 62 45 Lat,adjthr Evening 35 Lheg,adj,thr Lot 21 level 2 70 58 Type C Night N/A a7 40 Latadjthr 30 Laeg,adj.thr ' Refer to Figure 2 for location on map 2 Compactor and associated plant only operational between 7am and 6pm. On that basis, at other times noise impact is N/A — not applicable 3 Exhaust fan and other plant adjacent to loading docks only operational between 7am and 10pm. * Based on most exposed rooms and building locations as per Figure 4 The rooms assume typical bedroom and living room dimensions with bedroom glazed facade area of 7.4m”. Subject to final room and building layouts and the shielding offered by other buildings, the facade acoustic treatment requirements may differ and would need to be reviewed after plans are finalised. I\Mobs\2019\20191414\20191414.2\202009030BA_R4_Noise_Impact_Assessment.docx 24
Page 28
6 RECOMMENDATIONS
6.1 MANAGEMENT CONTROLS
It is recommended that operation of the compactor to be limited to the day time period only (7am - 6pm)
and not use kitchen exhaust and other mechanical plant adjacent to the loading docks between 10pm and
7am.
Furthermore, trolley collection must not occur after 10pm and prior to 7am.
Loading dock operation is to be limited to the time period between 3am and 10pm only, with refrigeration
trucks recommended to idle for a maximum of 15 minutes during unloading. This idling shall only occur
during the loading/unloading activity at the loading dock, and not whilst waiting to enter the loading dock
or along the boundaries. In the case of refrigeration trucks, planned entry times could be scheduled before
hand to ensure that no idling occurs along the boundaries or at the entry to the loading docks.
For all other trucks, no idling should occur within the sites at any time also with the exception of a short-
time pick-up/drop-off within the loading dock.
Such restrictions should be included if not yet followed (e.g. signs installed at the entry and along the
boundaries of the shopping centre loading docks and within loading docks). Furthermore, If trucks are to
remain idling whilst waiting to enter the loading dock, it is recommended that this is done away from the
site as otherwise the impacts can be adverse.
6.2 ACOUSTIC BARRIER
An acoustic barrier is recommended along the northern boundary of lots 21 and 19 adjacent to the
blockwork loading dock wall as shown in Figure 19. The height of the barrier must be a minimum of 1.8
metres above the loading dock ground level or top of the existing loading dock blockwork wall whichever
is higher, with a minimum surface density of 12 kg/m. This assumes that the pad heights of the residential
buildings do not exceed that of the loading dock concrete pad level.
Figure 19- Acoustic Barrier
+ coor
Pore
05"
2 505
Acoustic barrier 1.8m high above loading dock ground level or top of loading dock blockwork wall,
whichever is higher
I\Mobs\2019\20191414\20191414.2\202009030BA_R4_Noise_Impact_Assessment.docx 25
Page 29
6.3 RESIDENTIAL BUILDINGS FACADE CONSTRUCTION In addition to the management controls, to achieve the indoor noise levels within the considered habitable areas (refer to Section 5.2), the following minimum facade construction is proposed. Refer to Table 5 for specific locations where each Facade Type applies. Table 6 - Fagade Construction Recommendations Type Glazing Systems Facade Wall A Nominal openable glazing system - Rw33 Masonry construction or Cladded nominally with 6.38mm lam glass and seals | facade (9mm fibre cement sheet) on 90mm timber studs - cavity insulation (e.g. 75mm thick 11kg/m3 glasswool) — min 10mm thick plasterboard internally B Nominal openable glazing system - Rw35 Masonry construction or Cladded nominally with 10.38mm lam glass and facade (9mm fibre cement sheet) acoustic seals on 90mm timber studs - cavity insulation (e.g. 75mm thick 11kg/m3 glasswool) — min 13mm thick Fyrchek plasterboard internally Cc Nominal openable glazing system - Rw37 Masonry construction or Cladded nominally with 10.76mm lam glass and fagade (9mm fibre cement sheet) acoustic seals on 90mm timber studs - cavity insulation (e.g. 75mm thick 11kg/m3 glasswool) — min 2 layers of 13mm thick Fyrchek plasterboard internally In the case where any of the apartments/habitable areas are elevated with the floor exposed to noise from the shopping centre, the floor is assumed to be of concrete construction (nominally 150mm thick). Other construction details may be acceptable but must be reviewed and approved by an acoustic consultant in order to achieve indoor noise levels of finalised building layouts. The minimum roof construction must be of concrete or alternative colorbond with Anticon 145 and plasterboard ceiling with 75mm thick glasswool (11kg/m3) overlay. Where building layouts and locations or habitable areas differ from what has been considered, additional assessment is required. Buildings located further from the loading docks in comparison to the ones considered in this report must be constructed based on Type A construction as a minimum. I\Mobs\2019\20191414\20191414.2\202009030BA_R4_Noise_Impact_Assessment.docx 26
Page 30
6.4 MECHANICAL PLANT NOISE LEVELS In order to achieve compliance with the continuous noise criteria outlined in Table 1, the operational conditions must follow the recommendations in Section 5. a) ) ; i Va. fa ‘ays eo) “i 7 Mech. plant deck Exhaust/Mech. plant AL fl / nea > aS J Mech Plant Adjacent to Loading Docks Mech Plant Adjacent to Loading Docks Figure 20- Mechanical Plant Locations I\Mobs\2019\20191414\20191414.2\202009030BA_R4_Noise_Impact_Assessment.docx 27
Page 31
7 CONCLUSION ALC have conducted a noise impact assessment of the loading dock activities and mechanical plant located at Noosa Civic Shopping Centre, 28 Eenie Creek Road, Noosaville. The purpose of the assessment was to determine the predicted intrusive noise levels at the proposed subdivision site on Hofmann Road for lots 17, 18, 19, and 21. Previous noise monitoring data conducted by ALC (ref: 20191414.1/1501A/R2/SS, dated 15/01/2020) has assisted in establishing the acoustic environment associated to the subject site (Table 1 and 2). Provided the recommendations in Section 6 are implemented, the development is predicted to achieve compliance with the Noosa Shire Council assessment indoor noise criteria. We trust this information is satisfactory. Please contact us should you have any further queries. Yours faithfully, Gnil Acoustic Logic Consultancy Pty Ltd Omar Busaidi I\Mobs\2019\20191414\20191414.2\202009030BA_R4_Noise_Impact_Assessment.docx 28