Council archive · source document
20200903OBA_R1_Loading_Dock_Operational_Conditions · OPW20/0145
Table 3 -Rion NL42 Measurement Summary Date Average Acoustic Descriptor, dB(A) Leq Loo Lio Li D* E* N* D* E* N* D* E* N* D* E* N* 20/11/19 54 48 44 51 46 37 56 50 | 46 66 56 59 21/11/19 52 | 49 | 44 49 46 36 | 53 | 50 | 46 | 66 | 59 | 61 22/11/19 52 49 44 49 46 36 53 50 | 45 66 | 60 61 23/11/19 52 48 44 49 46 35 54 | 49 | 46 66 58 60 24/11/19 53 | 48 | 43 49 45 36 | 56 | 50 | 45 | 67 | 58 | 61 25/11/19 52 49 43 49 46 37 54 51 45 66 | 61 61 26/11/19 57 51 44 52 47 37 59 54 | 46 70 59 60 27/11/19 54 51 56 67 AVERAGE 53 49 44 50 46 36 55 51 46 | 67 | 59 | 60 * D- Day (7:00-18:00), E- Evening (18:00 — 22:00), N-Night (22:00-7:00) 4.2.2 Attended Measurement Results Table 4 -Loading Dock Activity, Attended Measurements Location’ Noise Source Acoustic Descriptor, dB(A) Leq Lax Lpeak 1 Mechanical plant @ 25 57 62 78 metres 2 Reversing signal from trolley 69 76 83 collection truck 3 Mechanical plant noise 71 73 85 through exhaust/grille @ 1 metre away ' Refer to Figure 2 for location on map. I\Mobs\2019\20191414\20191414.2\202009030BA_R4_Noise_Impact_Assessment.docx