5.2 NOISE CALCULATION Measured noise levels and mechanical plant noise data and operational conditions highlighted in the previous section have been used to calculate the predicted intrusive noise levels at the sensitive noise receptors (lots 17, 18, 19, and 21) based on the expected building layouts of the Lots as described below and indicated in the figures below. A SoundPLAN™ computer model was developed for these noise sources as described activities and used to predict noise emissions from the compactor and loading docks to the sensitive receptors (lots 17, 18, 19, and 21). Predictions were made for the following scenarios: e Allloading docks and compactor operating concurrently, representing the worst-case scenario for day time noise emissions. e All loading docks operating concurrently, representing the worst-case scenario for evening and night time noise emissions as per the description in Section 5.1; e Only the compactor operating within the hours nominated and assumed. e Mechanical plant operational scenarios as described in this report. The analysis was conducted based on the following assumptions: e Mechanical plant decks indicated in Figure 2 have a sound power level of 90 dB(A) Leg each. e Kitchen exhaust fan indicated in Figure 2 has a sound power level of 99dB(A) Lea; ¢ Loading dock trucks have a sound power level of 101 dB(A) Linax. e Refrigeration trucks were assumed to idle for 15 minutes whilst unloading, with a sound power level of 95dB(A) Leq at a height of 3m above the ground level. This idling was only assumed to occur in the loading dock, and not along the boundaries or at the entrance to the loading docks. The refrigeration trucks, therefore, must not enter the site prior to loading to wait for their turn. Such restrictions should be included if not yet followed (e.g. signs installed at the entry and along the boundaries of the shopping centre loading docks). ¢ For all other trucks, no idling was assumed within the sites within short term drop-off/pick-up occurring at the loading docks only (less than 10minutes) and such restrictions should be included if not yet followed (e.g. signs installed at the entry and along the boundaries of the shopping centre loading docks). ¢ Compactor indicated in Figure 2 has a sound power level of 100dB(A) Linax. e Kitchen exhaust fans being turned off between 10pm and 7am and other plant adjacent and within loading docks not operational after 10pm and prior to 7am. ¢ Compactor is not operational between 6pm and 7am; « No trolley collection between 10pm and 7am. e The presence of a 6m wide plantation buffer between the northern boundary of the residential lots and the shopping centre paved loading dock and entry boundary. e Facade line of proposed residential development approximately 8 metres from loading dock boundary (refer to the closest sensitive receiver buildings used in calculations indicated in figure below) I\Mobs\2019\20191414\20191414.2\202009030BA_R4_Noise_Impact_Assessment.docx 11
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
20200903OBA_R1_Loading_Dock_Operational_Conditions.pdfRelated documentApplication case desk ↗
About this file
- File size
- 5.9 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.