Approved Plan - MCU23/0131

of 2

Page text read automatically using OCR, there may be inaccuracies

Plans and drawings: the text below has words only, no drawings.

Log in to see the plans as drawn
                                                                                                                            ACCESSIBLE
                                                                       5,600                                               MALE + FEMALE
                                              REAR CARPARK
                                                                                                                                WC




                                                       500
                                                             STORAGE




                                                                                                                                                                     Yeppoon QLD 4703

                                                                                                                                                                     Telephone        0409 550 960

                                                                                                                                                                     [email protected]

                                                                                                                                                                     This drawing is to be read in conjunction with
                                                                                                                                                                     Specification, Schedules and all Consultants
                                                                                                                                                                     Drawings & Reports.
                                                                                                                                                                     Specification to take precedence over




                                                                                    EXTENT OF WALL HUNG MIRRORS
                                                                                                                                                                     drawings.
                                                                                                                                                                     Construction to comply with all relevant SAA
                                                                                                                                                                     & BCA Codes & standard Bldg By-law 1975 &
                                                                                                                                                                     as amended.
                                   EXISTING     CORRIDOR        REFORMER AREA                                                  EXISTING                              Builder to check & confirm all dimensions &
                                   MEDICAL                                                                                     TENANCY                               site conditions prior to commencement of any
                                   CENTRE                                                                                     (Pool Shop)                            works. Builder to report any discreprencies
                                                                                                                                                                     prior to commencing work. These drawings




                                                                                                                  15,600
                                                                                                                                                                     are not to be used for scaling.
                                                                                                                                                                     Site setout to be carried out by a licenced
                                                                                                                                                                     surveyor.

                                                                                                                                                                     ©Copyright for design & drawings remain
                                                                                                                                                                     the property of the authors.
                                                                                                                                                                     Builder to allow for all waste disposal from
                                                                                                                                                                     site for the period of Construction.
                                                                                                                                                                     Builder to allow for all waste disposal from
                                                                                                                                                                     site for the period of Construction.
                                                                                                                                                                     BCA:
                                                                                                                                                                     Supply mains connected smoke alarms
                                                                                                                                                                     compliant with AS3786 located as per BCA
                                                                                                                                                                     3.7.2.3
                                                                                                                                                                     Waterproof wet areas in compliance with
                                                                     SHOP 3B
                                                                                                                                                                     AS3740 & BCA table 3.8.1.1
                                                                 Total Area 88sqM


                                                                                                                                                                     Project:

                                                                                                                                                                     PROPOSED @PILATES STUDIO
                                                                                                                                                                     Location:

                                                                                                                                                                     3B/3 Station Street
                                                                RECEPTION AREA
                                                                                                                                                                     POMONA QLD 4569
                                                                                                                                                                     Client:

                                                                                                                                                                     Claire Devine
                                                                                                                                                                     Drawing Title:

                                                                   SHOPFRONT                                                                                         Proposed Floor Plan
                                                                                                                                                                     Scale:               Date:

                                                                                                                                                                     1:50 @ A2            01/10/23
                                                                                                                                                                     Drawn By:            Job No:

                                                                                                                                                                     CD                   2310
       PROPOSED FLOOR PLAN                                                                                                                     NOOSA COUNCIL         Drawing No.             Issue No.   Revision


                                                                                                                                                                     WD.201 P1
                                                                                                                                               APPROVED PLAN
       SCALE 1:50 @ A2                                           STATION STREET                                                             MCU23/0131 17 NOV 2023                                         A
GSPublisherVersion 231.83.83.100
Log in to download the original file

Approved Plan - MCU23_0131.pdf · 334 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.