a
. ae |
ken hicks
ANG ASSOCIATES
7 March 2007
Our Ref: 050718
Council Ref: 2006/718
The Chief Executive Officer
Noosa Shire Council
PO Box 141
TEWANTIN QLD 4565
ora
~7 MAR 2007
NOOSA SHIRE COUNCIL
FRONT COUNTER
Attention: Tracy Arthur
Dear Sir
RESPONSE TO REQUEST FOR FURTHER INFORMATION
DEVELOPMENT APPLICATION FOR MATERIAL CHANGE OF USE (COMMERCIAL BUSINESS
TYPE 2 MEDICAL & TYPE 1 OFFICE) AND ANCILLARY DWELLING UNIT
241 DAVID LOW WAY, PEREGIAN BEACH
LOT 20 ON P9315
EMMELLEA PTY LTD
COUNCIL FILE REFERENCE: 2006/718
We refer to the abovementioned development application for material change of use and further to
Council correspondence dated 16 May 2006 requesting further information with respect of the
proposed development.
On behalf of the applicant, Emmellea Pty Ltd, and in accordance with the statutory provisions of the
Integrated Planning Act 1997, we hereby address Council’s issues raised with the application in the
response below.
Amended proposal plans have been prepared by Saint Consulting Engineers and accompany this
response as Appendix A.
LAND USE
1. Revised plans and or written report which demonstrate compliance with The Noosa Plan code
requirements in respect of the following;
tem 1.1
! Confirm the number of medical practitioners and employees for the office and medical centre. .
{ Notably initial car parking calculations indicate that insufficient car parking has been provided on-site. —
bet
Response
The applicant advises the following with respect to the provision of car parking within the proposed
development and as confirmed by Council's Tracy Arthur at the meeting held with Council Monday 5
February 2007:
Type 1: Office
58sqm/20 = 2.9 spaces [minimum 4 spaces to be provided (8 staff allowable)]
Type 2: Medical Centre
2 x practitioners = 6 spaces
Ancillary Dwelling Unit
1 space (demand accommodated in spaces for Type 2: Medical Centre)
Total: 11 spaces required
8 spaces provided
TOWN PLANNERS | CONSULTING SURVEYORS | URBAN DESIGNERS | PROJECT MANAGERS
Ken Hicks & Associates Pty Ltd | Suite 7 Dalton Centre, 1 Newspaper Place, Maroochydore BC QLD 4558, PO Box 6380, Maroochydore BC 4558
P 07 5443 2844 | F 07 5443 7146 | A.C.N.010 278 823 | A.B.N. 74 308 405 611
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 26 pages
Page 2
The proposal plans prepared by Saint Consulting Engineers illustrate that eight (8) spaces are accommodated within the proposed redevelopment of the site. As discussed with Council the applicant is faced with working within the grounds of a defined space for the provision of minimum Council requirements such as car parking, landscaping, access ramps, stormwater management etc. The location of the existing dwelling on the site proves to be the predominant constraint to providing the minimum number of car parks without physically relocating the dwelling further to the rear of the site or pushing it forward towards the David Low Way frontage. The applicant is required to provide a minimum of 11 car parks within the development layout as illustrated above. It is submitted that demand for the 1 space for the ancillary dwelling unit is taken up in the spaces provided for the Type 2: Medical Centre. Thus a total of 10 spaces are required to be provided. As discussed with Council’s Tracy Arthur the applicant is willing to accept a condition imposed on a subsequent development approval stating that the ancillary dwelling unit is to be utilised for the purposes of the staff of the development only. Thus the demand for providing the 1 space in accordance with the Planning Scheme is not required. The applicant has advised that it is willing to pay a contribution for the balance 2 spaces that are not provided within the development at the applicable rate. At the time of discussion Council’s Tracy Arthur quoted a rate of $11,800.00 per space for the Peregian Parking Contribution Area. 9 spaces are physically achievable on the site however the parking bay directly opposite the disabled bay has become a turning area at the request of Council. Comment: the above response proves to resolve Council’s initial concerns with respect to the number of practitioners operating within the proposed commercial development and offers Council a solution in regards to the shortfall in parking provided within the constrained site. We trust Council will be amendable to the solution outlined in response to this item. Item 1.2 Inadequate landscaping has been provided to the road frontage. In this regard, the Landscaping Code requires an average width of 2 metres of soft landscaping be provided to the road frontage. Insufficient landscaping has also been provided to side boundaries, particularly between the side boundary and the proposed car parking area. Response The proposal plans prepared by Saint Consulting Engineers namely Drawing No. 010207-02: Proposed Site Plan illustrates the amended provision of landscaping within the development layout; in particular the car park and street frontage. The revised concept provides Council with what is considered to be an appropriate amount of landscaping. This landscaping together with the screen fencing provided on the side boundaries will serve to adequately screen the car park from the David Low Way. Taking into consideration the constraints of the site and the intention of the applicant to provide car parking in front of the retained dwelling, Saint Consulting Engineers have managed to achieve a 2m landscaped strip along the northernmost part of the frontage, with a 1.5m strip on the southernmost. As a result of this reconfiguration, the waste management area which includes the waste bins located upon entering the development has been relocated to a more desirable location from Council's perspective adjacent to the new turning bay. The provision of landscaping is considered supportable in light of the expansive setback the subject site maintains from the David Low Way (in the order of 13.5m) The existing landscaping within the Council road reserve will further contribute to breaking up the presence of the car park proposed by the applicant. Saint Consulting Engineers has made every effort to increase the landscaping on the side boundaries of the development however is bound by providing compliant car parking and aisle width dimensions in accordance with Australian Standards.
Page 3
The width of the landscaping on the northern boundary has increased marginally in addition to the opportunities for shade planting between the car parks. The inclusion of established species in these locations will achieve a desirable outcome for the site. It is reiterated that the applicant is working within a defined situation with the retention of the existing dwelling. The applicant has incorporated most of Council's requests with respect to car parking including the loss of 1 space for a vehicle turning area. Should this space not be provided an increase in landscaping on the southern most section of the front boundary may result. We encourage Council to keep this in mind when considering the response to the above item. Item 1.3 Demonstrate compliance with the Eastern Beaches Locality Code having regard to protecting the vegetated character of the David Low Way and its function, capacity and efficiency of the major road network. Response The proposed development has regard to the vegetated character of the David Low Way through the retention of various established species within the Council road reserve. This combined with the landscaping proposed by the applicant along the frontage of the site will serve to improve the streetscape character of this part of the David Low Way at Peregian. The removal of the existing fence and that originally proposed by the applicant will contribute to creating an attractive streetscape theme for future development along this section of the precinct. The single driveway proposed ensures the function of the David Low Way from a traffic and access perspective. . The proposal is considered to meet the applicable provisions of the Eastern Beaches Locality Code the vegetated character of the David Low Way and its function, capacity and efficiency of the major road network. Item 1.4 Further written justification to demonstrate compliance with the Eastern Beaches Locality code in regard to the extent of car parking at the front of the site. Note the proposal is not meeting the specific outcome of the Code which requires that car parking be provided at the rear of the site. Response As discussed at the meeting held with Council, it is not the intention of the applicant to relocate the existing dwelling on the subject site towards the David Low Way frontage. It is submitted that the above requirement of the Eastern Beaches Locality Code is more appropriate for the complete redevelopment of a site along this part of the precinct. It is on this basis that the applicant proceeds with the application in the current form making every effort to provide Council with a development outcome in respect of the car park and landscaping that will not compromise the relevant sections of the Code and the visual amenity of the David Low Way. Item 1.5 Demonstrate how the front fence complies with the requirements of the Eastern Beaches Locality Code. In this regard, the fencing is to be setback from the front property boundary and incorporate articulation, which allows for landscaping to be provided between the fence and the front property boundary. Response Please refer to the proposal plans prepared by Saint Consulting Engineers which indicate that the front fence previously proposed for this property boundary has been removed. The landscaping proposed along this frontage will become more apparent and will prove to visually enhance the development and streetscape from the current situation.
Page 4
LAND DEVELOPMENT Item Please note that Council allows for a single access driveway to each allotment. Therefore the proposed split driveway should be replaced with a combined driveway 5.5m wide maximum. A car turning space within the carpark will be required. Response Please refer to the proposal plans prepared by Saint Consulting Engineers namely Drawing No. 010207-02: Proposed Site Plan and Drawing No. 010207-10: Proposed Driveway Layout which illustrate the amended driveway leading from the David Low Way into the development site. The applicant has at the request of Council provided a single driveway which is tapered to the kerb allowing vehicles to safely enter and exit the site. The driveway has been designed taking into consideration the existing gully pit located within the kerb on the David Low Way frontage (refer photo below) and will serve to retain some exiting vegetation within the Council road reserve. The gully pit as illustrated on Drawing No. 010207-02: Proposed Site Plan prevents the applicant from providing a single driveway at right angles to the street. A vehicle turning bay has been provided at the request of Council. Item Provide design plan of the revised driveway and carpark showing the design levels and grades in compliance with AS/NZS 2890.1:2004. Response Please refer to the proposal plans prepared by Saint Consulting Engineers namely Drawing No. 010207-10: Proposed Driveway Layout which illustrates the proposed design of the driveway and car park including design levels and grades. Item 4 The actual depth and location of the existing 150mm water main located approximately 1.5m from the front boundary line (not shown on the submitted plans) should be determined to ensure a minimum 600mm cover be maintained over this pipeline. Probing or potholes is to be provided by Council at the applicant’s cost.
Page 5
Response Please refer to the proposal plans prepared by Saint Consulting Engineers namely Drawing No. 010207-02: Proposed Site Plan which illustrates the approximate location of the water main. The applicant advises Council that no earthworks or cutting will occur in this area for the driveway. The driveway will be made more solid than the existing due to the commercial standard which will further serve to protect the water main from any damage. Emailed correspondence (included as Appendix B) has occurred between Council’s John Fallon - Water and Sewerage Asset Management and Saint Consulting Engineers confirming that this can occur prior to building works. Item Provide documentation to clarify the legal right for the property to drain into the existing stormwater pipeline on the rear property. Response Please refer to the accompanying documentation included as Appendix G with respect to the legal right of discharge into the Council stormwater pipeline at the rear of the property. The lodgement of this documentation was deemed sufficient by Council's Monkeith Kadhum to address this matter. Item A general drainage design plan showing the stormwater disposal from the site including the provision of overland secondary flow path/s for 100 years storm events and demonstrate that the proposal will not have adverse impact on the drainage conditions over the adjoining properties. Response Please refer to the proposal plans prepared by Saint Consulting Engineers namely Drawing No. 010207-09: Earthworks and Sediment Control Plan and Drawing No. 010207-11: Stormwater Tank Schematic Plan which illustrate the proposed stormwater management proposal of the applicant. It is requested that Council seek further information with respect to the proposal with a subsequent operational works application. ENVIRONMENTAL HEALTH Ttem7 A Waste Management Plan (Operational) in accordance with Planning Scheme Policy “Waste Management Multi-Dwellings and Commercial and Industrial Premises”, must be submitted for the day-to-day operation of the complex and approved by Council's Environmental Health Section prior to issue of development permit for operational works. The Pian shall include the following information: - Ite The types of waste that will be generated from the activities approved within the development. Item 9 Estimated volumes or tonnage of recyclables within the generated waste stream Item 1 Estimated volumes or tonnage of waste generated from the activities. Item 11 Methods to be used for dealing with garden waste. Item 12 Initiatives to minimize waste either by waste prevention, reduction, re-use or recycling. Item 13 - Description of procedures involving disposing of refuse to bins; the storage of bins and the collection of bins by the contractor and who is responsible for each transfer of the waste. Item 14 A description of the design details of waste storage and recycling areas including size, location, elevation and floor pian, methods of bin washing and of prevention of storm water contamination.
Page 6
Item 15
A description of types and volume of waste storage containers to be used.
Item i
The waste and recycling storage area shall include the provision of containers for all waste and
recycling materials including putresable matter, non-recycling waste, paper and cardboard, glass,
aluminium and steel cans, waste oil, styrofoam boxes, etc, and bin washing facilities.
Item 17
A detailed description of vehicular access to collect waste. Where collection is off street, access must
allow vehicles to enter and leave the site in a forward direction.
Response
As confirmed with Council at the meeting held 5 February 2007 the above Waste Management Plan will
be provided to Council with a subsequent development application for operational works.
CONCLUSION
The above response to Council’s request for further information provides Council with sufficient
information in order to undertake a final assessment of the proposal.
Submission of this response completes the Information and Referral Stage of the IDAS and accordingly
we will proceed with the public notification of the application.
We trust that Council will duly consider the response and the amended layout proposed by the
applicant taking on board the fact that the proposal is reconfiguring an existing dwelling into a
commercial development.
The design of the development; namely the car parking and landscaping is constrained by the location
of the existing dwelling. It is considered that the proposed design solution provides Council with an
acceptable development outcome for the site.
Should you have any further queries in relation to the above, please do not hesitate me in the office.
Yours faithfully
KEN & ASSOCIATES
Page 7
APPENDIX A REVISED PROPOSAL PLANS SAINT CONSULTING ENGINEERS
Page 8
— Saint Consulting ENGINEERS A.B.N. 15 096 410 909 SIVIL, STRUCTURAL, HYDRAULIC ENGINEERING & BUILDING DESIGN MlEAust CPEng Aust.No.29986 1 STANLEY STREET, NAMBOUR QLD. 4560. RPEQ No.1476 NPER-3 No.40467 4560 QBSA Lic.No. 16080 PHONE : (07) 54412233 FAX : (07) 54763218 [email protected] \ = L PROJECT: RENOVATIONS/EXTENSIONS ADDRESS: LOT 20 DAVID LOW WAY, PEREGIAN QLD CLIENT: COUMBIS DENTAL SURGERY J \ e XV DRAWING REGISTER: SHEET NO. SHEET TITLE JOB NUMBER 010207 af \
Page 9
(C)_THIS WORK IS COPYRIGHT AND THE PROPERTY OF ROY K. SAINT PTY_LTD_ IT MUST NOT BE COPIED_ REPRODUCED RETAINED ON OR USED IN ITS ENTIRETY OR IN PARTS FOR ANY PURPOSE OTHER THAN THE SPECIFIC PURPOSE SET OUT HEREON WITHOUT WRITTEN PERMISSION
San eal (Seg Eee
1. This structure has been designed in accordance with the
current editions of the Building Code of Australio (BCA-96)
‘and the Queensland Building Act - Standard Building Law,
2. All building work shall comply with the current editions of
the relevant Australian and New Zealand Standards and other
documents as called up in the BCA-96.
3. Unless stated otherwise, all materials shall be as listed in
the Accredited Building Products Register.
4. The builder shall check and verify all dimensions, fixings,
fittings and finishes before commencement of works.
5. Reduced levels (RL’s) and ground contours as shown have
not been measured by the author of these documents and may
only indicate the approximate general shape of the terrain and
heights of the various building elements. Unless stated other—
actual accurate levels shall be determined either by the
builder or 9 land surveyor prior to commencement.
6. Written dimensions as show on the drawings take pre—
cedence. DO NOT SCALE DIRECT FROM THE DRAWINGS!. In the
event that questions arise, discrepancies or errors are
noticed, please do not proceed with the work without
requesting further instructions from the builder and/or the
building designer.
7. Construction must not vary from these drawings without
the written approval of the owner/s, licensed certifier and
the building designer.
8, Unless stated otherwise, these drawings have been prep—
ared either for client approval, planning approval or building
permit approval only. No responsibilty will be accepted by
the building designer for drawings or further construction (shop)
drawings prepared by others.
9. Any anchor rods/bolts and roof truss tie-down details
shown are for standard trusses only. The builder shall obtain
tie-down details for any non-standard trusses such as hips,
girders, valleys etc. from the truss manufacturer or struct—
ural engineer. This information shall be made available to
the Local Government or Licensed Certifier at the time of
lodgement of the Building Permit Application.
=\ *
10. Refer to the structural and/or geochemical engineering
report/s for footings and slab details not shown.
11, Unless stated otherwise, rainwater discharge either shall
be directed to the road kerb or dispersed within the prop—
erty boundaries to Local Government requirements.
12. TERMITE PROTECTION:
96 The building shall be protected from subterranean termites
by approved physical and/or chemical barriers in accordance
with AS3660.1. The precise method of protection shall be
determined by the owner/s and/or builder only after consult—
ation with a licensed pest control operator. This information
then shall be advised to the Local Government or Licensed
Certifier prior to, or at the time of lodgement of the
Building Permit Application.
TENNIS
COURTS
THEREAFTER, THE OWNER/S SHALL ENSURE that any physical
barriers are kept clear of garden beds and/or soil build up,
that any chemical barriers remain undisturbed and that annual
inspections (plus eradication os necessary) are carried out
throughout the life of the building by a licensed pest control
operator in accordance with AS3660.1.
RPD
LOT 20 on P9315
PEREGIAN BEACH
CONTRACTOR TO CONFIRM ALL DIMENSIONS &
LEVELS ON SITE PRIOR TO COMMENCEMENT
OF ANY WORK.
ALL CONSTRUCTION TO COMPLY WITH THE
AUSTRALIAN BUILDING CODE REQUIREMENTS
& RELEVANT AUSTRALIAN STANDARDS.
EXISTING SITE PLAN
SCALE 1:200 (A3)
sittin F EXISTING SITE PLAN ENO _ OYOOQOOOOOO
: { 1:200(A3) | ISSUE PRINTED: CADO01
GAG DESIGN - ) J | | is |
. . MiEAust CPEng Aust.No.29986,
( ENGINEERS 1 STANLEY STREET, NAMBOUR QLD. 4560 456 as
eR RLAK CRN U is PHONE ; (07) 54412233 FAX : (07) 54763218 } URA : 01 0207-01
[email protected] FOR
ISSUE | _DATE REVISION
Page 10
C)_THIS WORK IS COPYRIGHT AND THE PROPERTY OF ROY K. SAINT PTY. LTD. IT MUST NOT BE COPIED, REPRODUCED RETAINED ON OR USED IN ITS ENTIRETY OR IN PARTS FOR ANY PURPOSE OTHER THAN THE SPECIFIC PURPOSE SET OUT HEREON WITHOUT WRITTEN PERMISSION
5
ROOFWATER STORAGE TANK WITH RAINWATER
SWITCH TO TOWN WATER SUPPLY WHEN TANK
LEVEL IS LOW. WATER TO RETICULATE TO BUILDING
TOILETS AND EXTERNAL LANDSCAPED AREAS TO
COUNCIL & AS3500 STANDARDS
TO UPPER LEVEL TO BCA REQUIREMENTS e
(tin14 MAX GRADE)
®
g 2
= 4
3 EXISTING
x <\ CATCHPIT
TBM
sl SI
} ei
PROPOSED
CARPARK
600 SQR FOX BCGPT
OR EQUIVALENT
19 SCREENED WHEELIE BIN ENCLOSURE
5000 LITRE STORMWATER DETENTION
TANK FROM CARPARK GPT CONCRETE FOOTPATH AROUND
TENNIS WITH 100 DIA LOW FLOW OUTLET TO LOWER STOREY ANCILLARY DWELLING ENTRY
COURTS DISCHARGING TO NEW PIT OVER
EXISTING STORMWATER SYSTEM
NEW 600 SQR STORMWATER PIT
BUILT OVER EXISTING STORMWATER DRAINAGE
FOR STORMWATER DISCHARGE
PROPOSED SITE PLAN
THE BUILDING SITE IS SCALE 1:200 (A3)
APPROX. LEVELS
TO BE CONFIRMED
BY THE BUILDER
T PARA
TOTAL ALLOTMENT AREA = 582 sqr.m.
FINAL BUILDING LOCATION & LEVELS TO BE BUILDING ENVELOPE SITE COVERAGE = /40 sqr.m. (24% Site Coverage)
DETERMINED ON SITE BY BUILDER
WITH OWNER
SOFT LANDSCAPING = /67 sqr.m. (29% Site Coverage)
CARPARK & RAMP COVERAGE = 275 sqr.m. (47% Site Coverage)
RPD > eae, Sera reer ale ee RETAINED ?
LOT 20 on P9315 éx ONSTRUCTED AS REQUIRED TO SUIT
: 3 NEW ENTRY XIT DRIVEWAYS
PEREGIAN BEACH a \é : Seen cigecke | OSIYERA
aavd
VEGETATION TO ROAD FRONTAGE
CONTRACTOR TO CONFIRM ALL DIMENSIONS &
LEVELS ON SITE PRIOR TO COMMENCEMENT
OF ANY WORK.
ALL CONSTRUCTION TO COMPLY WITH THE
AUSTRALIAN BUILDING CODE REQUIREMENTS
& RELEVANT AUSTRALIAN STANDARDS.
—_ PROPOSED SITE PLAN Ee VOODOO OO000
GAG DESIGN 4 ) . " 1:200 (A3) ISSUE PRINTED: CADO01
* . MIEAust CPEng pine 29986
RPEQ No. 1476 NPER-3 No.40467 AT
Saint,Consulting zens
{ ENGINEERS TANLEY STREET, NAMBOUR QLD. 4560. 456
< ; > cei sous alu oes (ONE - (07) 4412233 FAX : (07) 54763218 DRAWIN p Vee
ISSUE | DATE REVISION o - [email protected] FOR
Page 11
(c) THIS WORK |S COPYRIGHT AND THE PROPERTY OF ROY K. SA INT PTY. LTD IT MUST NOT BE COPIED. REPRODUCED ‘AINED ON OR USED IN ITS ENTIRETY OR IN PARTS FOR ANY PURPOSE OTHER THAN THE SPECIF iC PURPOSE SET VRITTEN PERMISSION ELEVATIONS = Deck Bedroom Living ® 9000 x Kitchen | Bathroom | Le Len EXISTING ELEVATION A Seale 1:100 (A3) Bedroom Bedroom DEVELOPMENT AREAS CONTRACTOR TO CONFIRM ALL DIMENSIONS & LEVELS ON SITE PRIOR TO COMMENCEMENT OF ANY WORK ALL CONSTRUCTION TO COMPLY WITH THE AUSTRALIAN BUILDING CODE REQUIREMENTS & RELEVANT AUSTRALIAN STANDARDS EXISTING FLOOR AREA = /09 sqr.m. EXISTING FLOOR PLAN Scale 1:100 (A3) 7800_APPROX TO BE CONFIRMED ON SITE BY BUILDER PRIOR TO BUILDING WORKS EXISTING ELEVATION D EXISTING ELEVATION B EXISTING ELEVATION C Scale 1:100 (A3) Scale 1:100 (43) Scale 1:100 (43) EXISTING BUILDING PLANS OOOOOO0O0O 1:100 (A3) ISSUE PRINTED: CAD001 010207-03 GAG DESIGN Mi€Aust CPEng Aust.No.29986 76 NPER-3 No.40467 Saint, Consulting a \ ENGINEERS ” A.B.N. 15.096 410 909 412233 FAX : (07) 5 roy@saintconsulting org ISSUE DATE REVISION
Page 12
ORK IS COPYRIGHT AND THE PROPERTY OF ROY K. SAINT PTY. LTO. IT MUST NOT BE COPIED, REPRODUCED RETAINED ON OR USED IN ITS ENTIRETY OR IN PARTS FOR ANY PURPOSE OTHER THAN THE SPECIFIC PURPOSE SET OUT HEREON WITHOUT WRITTEN PERMISSION EXISTING TO BE RENOVATED NEW EXTENSION =e _—_ 12000 3240 2640 3120 3000 NEW RAMP GRADED @ lin/4 WITH NON-SLIP FINISH AND HANDRAILS TO 8CA REQUIREMENTS 70 70 70 70 70 3170 530 5020 2930 STAIRS, HANDRAIL & BALLUS TRADE TO BCA REQUIREMENTS 3 z FFL10.3 5 2 i 3 Deck 3 = > 2 8 Deck Video Room = nN sb S wo = . \_| wee ; ~ a = ee ] (EXIT) s , Staff Rom |[ — I = fiat _ S 8 || Waiting Room Office & =] ll eZ nN et Ed ot! it | Ss — | L AN S Ss 5 ° FFL9.37 2s x s Es Unisex tt ; | aes = & Ol (Beception. —_ — — _ 4 a > = T 3 4 Lab 3 ia | esos a ein 2 a ll S é ll lI Ss Surgery | i eo Surgery 2 Py = a a Feeeee eas a 3 rc) 3 Surgery 3 3 | a-Fa | os ———$_——» — I a ll s ie 2 Jl e _ jj 2 " 2200 - 6590 0 1000 1860 ” PROVIDE ALL NECESSARY XRAY WALL, FLOOR, CEILING & DOOR TREATMENT AROUND EACH INDIVIDUAL DENTAL SURGERY ROOM 70 70 70 70 70 70 TO CONTAIN XRAY IN ACCORDANCE MTH DENTAL PRACTISE 3250 1400 3000 1000 2930 REQUIREMENTS 12000 PROPOSED UPPER FLOOR PLAN Scale 1:100 (A3) e DENOTES HARDWIRED SMOKE DETECTOR INSTALLED TO BCA REQUIREMENTS DENOTES ILLUMINATED EXIT SIGN TO BCA REQUIREMENTS. [EXIT] FINAL LOCATION AND EXTENT OF EXIT SIGNS TO BE DETERMINED ON SITE BY BUILDER AND ELECTRICIAN DEVELOPMENT AREAS PROPOSED MEDICAL GROSS FLOOR AREA = 1/6 sqr.m. PROPOSED UPPER DECK GROSS FLOOR AREA = 2/ sqr.m. PROPOSED LOWER ANCILLARY DWELLING GROSS FLOOR AREA = 50 sqr.m. PROPOSED LOWER OFFICE GROSS FLOOR AREA = 58 sqr.m. TOTAL GROSS FLOOR AREA = 245 sqr.m. ALLMAN WINDOWS: All aluminium framed windows and sliding door units shall be to ASIZ88, shall be to matching design and be supplied mth @ ™anutocturers guarantee of suitablity for the relevant design mnd speed. INTERNAL LININGS: Unless stated otherwise, internal linings shal be 10mm Gyprock. Where required, internal timber framed bracing walls shall be lined with 6mm Hoardiflex, Wel area walls shall be lined with 6mm Villoboard. Ceiling battens shall be either 50 x 38 F5 (ar better) pine or equivalent galvanized steel turning channels. Al to manufacturers specications. ROOFING: Selected Colorbond stee! mith sarking and honzonta/ bracing to roof truss manufacturers specitications. FASCAS AND GUTTERS: Selected matching Colorband steel to monutocturers specifications. EXTERNAL WALLS: Unless stated otherwise, selected facebrick to ASJ700 nth approved brick bes installed ot 300mm maximum centres at oll Floor fevels and at the 2nd brick course from the top plus at 600mm max. horizontal and vertical centres in general wall areas. DPC. shall be built in below each FFL. and wall qpening. Weep holes shall be at 900mm maximum centres at oll OPCS. Selected waterproof texture coator concrete render to manuf. spec. to all external surfoces. ROOF STRUCTURE: Unless stated otherwise, 55 x 70 8 (or better) battens at 900mm maximum centres fixed to 1/90mm No. 14 lye 17 screw (50mm penetration for Joint Group J04 timber) to engineered roof trusses. Trusses shall be at 900mm maximum centres and to monutocturers specifications. Doors to sanitary compartments without 1200mm clear space between the back of the door and the closest obstacle (such as the toilet bow! or hand basin) must either open outwards, slide or be readily removable from the outside. All concrete slabs and footings shall be to structural engineer's recommendations and in compliance with AS2870. Unless stated otherwise, the owner/s and builder shall agree as to the location, type and quality of all fittings, fixtures and finishes prior to commencement. HANDRAIL & BALUSTRADES BALUSTRADE POSITIONED MIN 865mm ABOVE NOSING OF TREADS. 1m MIN. ABOVE BALCONY,LANDING OR THE LIKE OPENING IN BALUSTRADES TO BE CONSTRUCTED SO A 125mm SPHERE IS NOT PERMITTED TO PASS THROUGH & FOR A STAIR THE SPACE TESTED 'S ABOVE THE NOSING. ALL STAIRS HANDRAILS & BALUSTRADES TO COMPLY WITH BCA 1996 PART 3.9.1 & 3.9.2 HORIZONTAL STEEL WIRE DO NOT USE IF DECK HT EXCEEDS 4.0M FROM FINISHED GROUND LEVEL 125x50mm TOP RAIL WITH SUPPORTS @ 1800c/c MAX. HORIZONTAL STEEL WIRE RAILS @ 80mm c/c MAX DROPPERS @ 600mm c/c MAX 6m MAX. TO EACH TENSIONING POINT. GAG DESIGN ee = A.B.N. 15.096 410 909 / Saint Consulting ENGINEERS PROPOSED UPPER PLAN AT 1:100 (A3) ISSUE PRINTED: CADO001 010207-04 ISSUE DATE REVISION QOOOOOOOO0O
Page 13
HT AND THE P
ERTY OF ROY K. SAINT PTY LTD. IT MUST NOT BE COPIED. REPRODUCED RETAINED ON OR USED IN ITS ENTIRETY OR
IN PARTS FOR ANY PURPOSE OTHER THAN THE SPECIFIC PURPOSE SET OUT HEREON WITHOUT WRITTEN PERMISSION
70 70 70
1800 2780
SCREENED AND SECURED COURTYARD
TO OWNERS REQUIREMENTS
COURTYARD
70 ~=—70 70
1500-900 4600
COURTYARD
ee = SS
70
900
Bathroom
Kitchen
1830
|
Kitchette E|
70
Living Room
&
2920
Entry
Shee
70
3000
concrete footpath
Bedroom 1 - Bedroom 2
70
concrete footpath
LANDING ABO
PROPOSED LOWER FLOOR PLAN
Scale 1:100 (43)
DENOTES HARDWIRED SMOKE DETECTOR
INSTALLED TO BCA REQUIREMENTS
DENOTES ILLUMINATED EXIT SIGN TO BCA REQUIREMENTS.
[EXIT] FINAL LOCATION AND EXTENT OF EXIT SIGNS TO BE DETERMINED
ON SITE BY BUILDER AND ELECTRICIAN
CONCRETE STAIRS TO BCA REQUIREMENTS
EXTENT TO BE DETERMINED ON SITE
NEW MASONRY RETAINING WALL TO RETAIN
EDGE OF CARPARK CIVILWORKS — REFER SITE PLAN
FOR DETAILS. Im HIGH HANDRAIL
TO THE TOP OF ALL WALLS
ALUMINIUM WINDOWS: Al aluminium framed mindows and stiding door
units shall be to AS1288, shall be to matching design and be supplied mth
2 ™anutocturers guarantee of suitablity for the relevant design mnd speed.
INTERNAL LININGS: Unless stated othermse, internal linings shall be 10mm
Opprock. Where required, internal timber framed brocing wals shall be
ined with 6mm Hordilex. Wet area walls sholl be lined with bmm
Viloboard. Ceiling battens shall be either 50 x 58 F5 (or better) pine
or equivalent galvanized steel fuming channels. All to manufacturers
specifications,
ROOFING: Selected Colorbond stee/ mith sarking ond horizontal bracing to roof
truss manufacturers specifications.
FASCUS AND GUTTERS: Selected matching Colorbond stee/ to
monvtacturers specifications.
EXTERNAL WALLS: Unless stated otherwise, selected facebrick to ASI700
mith approved brick tes installed at 300mm maximum centres ot oll
oor kevels and at the 2nd brick course from the top plus at 600mm
max. honizontal and vertical centres in genera/ woll areas. DPC. shall be
built in below eoch FFL. and wall opening. Weep holes shall be
at 900mm maximum centres ot ol DP.CS. Selected waterproof
(fexture cootor concrete render to manuf spec. to all external surfoces.
ROOF STRUCTURE: Unless stated otherwise, J5 x 70 F8 (or better)
battens at 900mm maximum centres fired to 1/90mm No. 14 Type 17
screw (50mm penetration for Joint Group JO4 timber) to engineered
root trusses. Trusses shall be at 900mm maninum centres and to
monvtaocturers specifications.
Doors to sanitary compartments without 1200mm clear
space between the back of the door and the closest
obstacle (such as the toilet bow! or hand basin) must
either open outwards, slide or be readily removable
from the outside.
All concrete slabs and footings shall be to structural
engineer's recommendations and in compliance with
AS2870.
Unless stated otherwise, the owner/s and builder shall
agree as to the location, type and quality of all
fittings, fixtures and finishes prior to commencement.
HANDRAIL & BALUSTRADES
BALUSTRADE POSITIONED MIN 865mm ABOVE NOSING OF TREADS.
im MIN. ABOVE BALCONY,LANDING OR THE LIKE
OPENING IN BALUSTRADES TO BE CONSTRUCTED SO A 125mm SPHERE
IS NOT PERMITTED TO PASS THROUGH & FOR A STAIR THE SPACE TESTED
IS ABOVE THE NOSING.
ALL STAIRS HANDRAILS & BALUSTRADES TO COMPLY WITH
BCA 1996 PART 3.9.1 & 3.9.2
HORIZONTAL STEEL WIRE
DO NOT USE IF DECK HT EXCEEDS 4.0M FROM FINISHED GROUND LEVEL
125x50mm TOP RAIL WITH SUPPORTS @ 1800c/c MAX
HORIZONTAL STEEL WIRE RAILS @ 80mm c/c MAX.
DROPPERS @ 600mm c/c MAX
6m MAX. TO EACH TENSIONING POINT.
GAG DESIGN
REVISION
Saint, Consulting
{ ENGINEERS
* A.B.N, 15.096 410 909
MIEAust CPEng Aust.No.29986
RPEQ No. 1476 NPER-3 No.40467
QBSA Lic.No. 16080
1 STANLEY STREET, NAMBOI
INE : (07) 54412233 FAX : (0
[email protected]
PROPOSED LOWER PLAN
AT
FOR
OOOOOOOOO:
1:100 (A3) ISSUE PRINTED: CADO01
010207-05
ISSUE DATE
Page 14
— oo —“——
) THIS WORK IS COPYRIGHT AND THE PROPERTY OF ROY K. SAINT PTY. LTD. IT MUST NOT BE COPIED, REPRODUCED RETAINED ON OR USED IN ITS ENTIRETY OR IN PARTS FOR ANY PURPOSE OTHER THAN THE SPECIFIC PURPOSE SET OUT HEREON WITHOUT WRITTEN PERMISSION
THTHTATH
THT
PROPOSED ELEVATION B PROPOSED ELEVATION C
Scale 1:100 (43) Scale 1:100 (43)
8000 APPROX
MAX 8000 BUILDING HEIGHT NOT TO BE EXCEEDED
PROPOSED ELEVATION A PROPOSED EES venoms
Scale 1:100 (43)
— 5 PROPOSED ELEVATIONS _ OOOOOOOO0O
GAG DESIGN 1:100 (A3) ISSUE PRINTED: CADO001
MIEAust CPEng Aust.No 29966
(Saint, Consulting sa:ss™*«
ENGINEERS
~ ———"_ ABN. 15096 410 909
ISSUE DATE REVISION = r= [email protected]
AT
2} vive wo 010207-06
Page 15
—————————
(c) THIS WORK |S COPYRIGHT AND THE PROPERTY OF ROY K. SAINT PTY. LTD. IT MUST NOT BE COPIED, REPRODUCED RETAINED ON OR USED IN ITS ENTIRETY OR IN PARTS FOR ANY PURPOSE OTHER THAN THE SPECIFIC PURPOSE SET OUT HEREON WITHOUT WRITTEN PERMISSION
PREFABRICATED TIMBER ROOF TRUSSES @ 900 CTS
TO MANUFACTURERS DESIGN & SPECIFICATIONS STAIRS & BALUSTRADES
1. STAIRS SHALL BE CONSTRUCTED TO THE REQUIREMENTS OF BCA PART
EXISTING ROOF FRAMING TO BE RETAINED IF POSSIBLE 3.9.1 ‘ °
AND NEW ROOF PITCHED OVER TO MANUFACTURERS
PROVIDE R2.5 MINIMIN ROOF INSULATION DESIGN & SPECIFICATIONS 2. STAIRS SHALL HAVE A MAXIMUM RISE OF 190mm. MINIMUM GOING OF 240
TO CEILING SPACE TO MANUFACTURERS SPECIFICATIONS 2% 50° == AND WITH A SLOPE RELATIONSHIP (2R+G) OF 550min. TO 700max
ap Oop a 3. TREADS AND BALUSTRADES MUST BE CAPABLE OF ALLOWING A 1259
“One, Ln = SPHERE THROUGH OPENINGS.
Ry p XY =I ;
= 4, BALUSTRADES TO STAIRS MUST NOT BE LESS THAN 865mm HT MEASURED
Ly by Pp, & _ COLORBOND ROOF SHEETING FROM THE STEP NOSINGS, AND 100mm HT. AT
Sint Bi 70 OWNERS CHOICE LANDINGS OR BALCONIES,
ap a
S
a 90x70 F 11 HANDRAIL
|S
450 EAVE 450 EAVE S\= DOWEL BALUSTERS
T.B.C. SZ T.B.C. a! & TO MATCH EXISTING
2 a by REFER FLOOR FRAMING PLAN AT 125mm MAX. CTS
32 =
S
| o>
@ PROVIDE FIRE RATED CEILING LINING
BETWEEN UPPER AND LOWER AREAS 90x90 F 11 END AND SOM5.F-14
5 708.C.A. REQUIREMENTS | INTERMEDIATE BOTTOM RAN
eo a POSTS
@ = Ss !
~ S EXTERNAL CLADDING TO re
SS OWNERS CHOICE |_
3 a 250x75 F.14 UNSI
z TREADS MAX. 14
ae or eee ai eel ae oe
TT Li “Uy = 250x50 F.14 UNSEAS.
LJ TIMBER STRINGER m
MAX. HOUSING FOR TIMBER
REFER FOOTING PLAN FOR DETAILS means
TYPICAL SECTION 2R+G=610 OK
Scale |: 100 (A3) TYPICAL GOING.
cale I.
BE IN ACCORDANCE WITH THE B.C.A CLAUSE
TERMITE PROTECTION LL BE CONSTRUCTE ACCORDANCE W' THE
| a | TIMBER ELEMENTS LL BE IN ACCORDANCE W
2
PROVIDE TERMITE PROTECTION IN ACCORDANCE WITH AS 3660.01 | | RISER
— 2000 USING LICENSED CONTRACTOR. INSTALL A “PHYSICAL \ AND GOING MENSIONS in?
BARRIER” TO PERIMETER OF SLAB & TO ALL PENETRATIONS & “ | i
PART B SPRAY IN ACCORDANCE WITH AMENDMENT 8 OF BCA. a nel Fe icakcba
ATTACHMENTS TO BUILDINGS: ATTACHMENTS TO BUILDING, SUCH AS 600 310 | PUBLIC STARS DO = 95 BO 700 50
DOWNPIPES AND SERVICE PIPES SHALL HAVE A NOMINAL GAP, TO ad AEG b |
ALLOW CLEAR AND UNINTERRUPTED INSPECTION ACROSS THE | meshes. Sole “Satie
INSPECTION ZONE
1050 535 |
STRUCTURES SUCH AS STEPS, VERANDAHS, PORCHES, ACCESS 1200 615 | coed
RAMPS, CARPORTS, TRELLISES, DECKS, HOT WATER SYSTEMS, AIR \ ——-
CONDITIONERS, OR SIMILAR, WHICH ARE NOT PROVIDED WITH ONE OF 1350 690 | Boe
THE BARRIER SYSTEMS DESCRIBED IN THE |
AS 3660.1-200, SHALL BE SEPARATED FROM THE BUILDING BY A 1500 765 j j
GAP OF AT LEAST 25mm, TO ALLOW CLEAR AND UNINTERRUPTED t J
VISUAL INSPECTION ACROSS THE INSPECTION ZONE. 1800 920
WHERE ATTACHMENTS OR STRUCTURES, AS OUTLINED ABOVE, ABUT 2100 1070 SHADE WIDTHS for Note: dv PRIVATE STARS ARE
A BUILDING AND THERE IS NO CLEAR GAP, THEN A BARRIER SHALL
BE PROVIDED TO THE ATTACHMENT, REGARDLESS OF THE SIZE OF 2400 1225 OPENINGS © STAIRS IN A CLASS 1.0 10 BUILDING
THE ATTACHMENT. 4 STAIRS IN A SOLE-OCCURANCY UNIT IN A CLASS 2 BUILDING OR CLASS 4 PARE AND
> IN ANY BUILDANG, STAIRS WHICH ART NOt PART OF A REQUIRED Exit AND tO WHICH THE
BRIDGING AND BREACHING. PUBLIC DO NOt NORMALLY HAVE ACCESS,
WER: Al iT TR' Ri XTURI R > THE GOING IN TAPERED [READS «AS IN A CURVED OR SPIRAL STAIR IS MEASURED -
BARRIERS SHALL NOT BE BRIDGED BY STRUCTURES, FIXTU ES Of CONTRACTOR TO CONFIRM ALL DIMENSIONS & >
FITTINGS ATTACHED TO THE MAIN BUILDING ( E.G. HOT—WATER © ZTomm Wi rROM HE OUTER SIDE IF THE FLIGHT IS Loss fan
SYSTEMS, STEPS, VERANDAHS ACCESS RAMPS CLADDINGS, LEVELS ON SITE PRIOR TO COMMENCEMENT MES
CARPORTS, TRELLISES OR SIMILAR STRUCTURES), NOR SHALL THEY OF ANY WORK. > 270m FROM EACH SIDE. IF THE PLIGHT IS MOR MORE Wite,
BE BREACHED BY THE INSTALLATION OF SERVICE ENTRY POINTS, ALL CONSTRUCTION TO COMPLY WITH THE Soa At Ger nee a h AND WuSt BE NOt LEDS THAN
DOWN PIPES, AN ADDITIONAL SLAB, PATHWAYS, LANDSCAPING, AUSTRALIAN BUILDING CODE REQUIREMENTS
GARDENING, OR SIMILAR, UNLESS ADDITIONAL BARRIERS ARE USED & RELEVANT AUSTRALIAN STANDARDS.
TO DETER CONCEALED ACCESS BY TERMITES TO THE STRUCTURE.
. — TYPICAL SECTION == OOODDOO0OO0
GAG DESIGN ) | 1:100(A3) | ISSUE PRINTED: CADO001
. . MIEAust CPEng Aust.No.29986
Saint Consulti n RPEQ No.1476 NPER-3 No.40467 eG
{ J g QBSA Lic.No. 16080
ENGINEERS 1 STANLEY STREET, NAMBOUR QLD. 4560 4561
2 * A.B.N. 15 096 410 909 PHONE : (07) 54412233. FAX : (07) 54763218 DRAWING P 0 1 0207-07
ISSUE ___DATE REVISION — roy@saintconsulting org FOR 1
Page 16
————————
c THIS WORK IS COPYRIGHT AND THE PROPERTY OF ROY K. SAINT PTY LTD. IT MUST NOT BE COPIED. REPRODUCED RETAINED ON OR USED IN ITS ENTIRETY OR IN PARTS FOR ANY PURPOSE OTHER THAN THE SPECIFIC PURPOSE SET OUT HEREON WITHOUT WRITTEN PERMISSION
200 to <
“ PAN aoe st
to 60 Pe Se
— | Zone for position of >
toilet paper dispenser 12 =
Grab jrail continues = %
where not obstructed 50 to ys 600 Min. ba 2
by cister f—1 2S
[ yy Cl m 60 le B
Top of seat lf<e
oO 3 |e
E ls
es
\ \ 300 Max. z 3
: See 4 =
450 to 460 = = =
3 =
3 100 t Dispenser may be to the ~+ 3
a 150 left or right of user 2
&
600 min.
800 to 810
50 Max. | 300 Min. |
at
{\. 400 Max. / |
NN (
GRAB RAIL AT BACK OF PAN AND
SECTIONAL VIEW OF GRABRAIL AT
SIDE OF PAN
Scale 1:20
Finished wall surface
DISABLED AMENITIES -
ALL ACCESS SIZES, WIDTHS AND CLEARANCES AS REQUIRED BY AS 1428.1
FOR ACCESS TO THE BUILDING FOR DISABLED PERSONS SHALL BE MET
AND ALLOWED FOR. ENSURE TOILET AREAS, DOOR CLEARANCES AND
FIXTURE LOCATIONS ARE ALL AS PER CODE. FIXTURES, TAPWARE AND
DOOR FURNITURE SHALL COMPLAY TO AND BE DESIGNED IN ACCORDANCE
WITH THE RELEVANT CODES AND BY-LAWS
50 to
800 to 810
Finished Wall Surface
A critical dimension
GRAB RAIL AT SIDE OF PAN
Scale 1:20
1600 Min.
1150 Min.
450 to
460
[600 |max. |
0 |
Max.
| 600 min. above floor
/
800 Min.
ZONE FOR POSITION OF
TOILET PAPER DISPENSER
Scale 1:20
| 300 Mox. | Front edge
of
Capstan type handle to both plug hole, La lecibcat or any
centre-line of tap other fixture
Lever type handle or end of lever arc
aS yr
Centreline of top
or where a lever
handle is provided.,
the end point of
the lever measured
throughout its
arc of movement
Ee Datum point
Centre-line of drainage
,
3 ee Fahne ben outlet or control
SS=5 1 ~~ .
: Sar 2 g
L ; 2
ical washbasin ° y ! g 3 y 3 2
/ . : 2 ~
Ae eet wv ——-s ee 2
ss 0 tT | . an | 3 : :| =
Scien EE 11 Sle i §| 8 190 to 200} El
ashbasin sg mu LL i al fo EE SSS 3!
pects | S | | =
1
fg
| 490 min. | 300] 700. min. | I J
' "in l
Legend:
Legend: chien cats nd —-—-—= Outer limet of obstructions beneath the washbasin
—-—= Circulati —-+—= Circulation space Note:
Note: a Note: The dimensions of the unobstructed space beneath the washbasin
This circulation space can overlap any other circulation This circulation space can overlap any other circulation are critical dimensions, and it is recommended that a template be provided.
spaces specified in this Standard. spaces specified in this Standard. POSITION OF WASHBASIN AND FIXTURES
These dimensi t in mirror figurati ,
CIRCULATION SPACE CIRCULATION SP ‘ce AND OUTER LIMIT OF OBSTRUCTIONS
FOR WASHBASINS BENEATH THE WASHBASIN
cule 1:5 IN WATER CLOSETS or
; Cal:
. DISABLED DETAILS OOOOOOO000
GAG DESIGN N.T.S.(A3) | ISSUE PRINTED: CADO001
int, ( peragbont ar
/Saint, Consulting since" zt
ENGINEERS 1 EY STREET BANEOUR Ot D
ISSUE |_DATE REVISION = esas ies Oe FOR 01 0207-08
Page 17
ISSUE DATE
(E)_THIS WORK IS COPYRIGHT AND T
+
HE PROPERTY
OF ROY K. SAINT PTY
LTD. IT MUST NOT BE COPIED. REPRODUCED RETAINED ON OR USED IN
V ITS ENTIRETY OR IN PARTS FOR ANY PI
JRPOSE OTHER THAN T
HE SPECIFIC PURPOSE SET OUT
PROPOSED SILT FENCE BELOW
HEREON WITHOUT WRITTEN PERMISSION
TENNIS
COURTS
o0st
SEDIMENTATION NOTE:-
ALL EARTHWORKS AREAS TO BE PROTECTED FROM
DAMAGE BY STORMWATER. EXISTING TABLE DRAINS TO
BE GRADED TO PREVENT PONDING AND DETENTION OF
TO PREVENT ANY PONDING OF STORMWATER. LOCATION
OF SEDIMENT FENCES INDICATIVE ONLY, FINAL
LOCATION, LENGTH AND NECESSITY TO BE DETERMINED
ON SITE BY ENGINEER. ALL SILTATION CONTROL
DEVICES TO BE IN ACCORDANCE WITH I.E.AUST
SEDIMENTATION GUIDELINES. ALL SILTATION CONTROL
DEVICES TO BE REGULARLY MAINTAINED AS DETERMINED
ON SITE. ALL STORMWATER AND TRENCHING
CONSTRUCTION TO BE PROTECTED DURING
CONSTRUCTION PERIOD TO REDUCE RISK OF SILTING UP
AND SCOUR DAMAGE.
| EY DEVELOPMEMT,
as | FY
Q\\ i
a \ \ \ \
| \ LS
. N
\ \ we
RUNOFF. ALL EARTHWORKS TO BE SHAPED AND GRADED
DEVELOPMENT SECTIONS
2
_—- 4
eT. s 8
= 10 >
o
py ERIN : 7 <
a 5 \ \ \ 6 oS
RKO pt 2 \ \ \ =
Dole \ \ 3 — i
Yao \ .
\ \ \ 7 TBM <Q h
a ‘ae Sy NO} aa D\. 5
a \ $ >
1 ez \ “i a =
PROPOSED \ &
\ CARPARKING , ee
PBROPOSE, SS Se es Ms '
ah > aT
HE Bee bo eee :
we > \ . \ yO
=: : 7 \ f <2 ne
ee eee [Roig
\ \ >
ea 7g ! @°
: Be ‘| ) KE
600 SQR FOX BCGPT
OR EQUIVALENT
EXCAVATED SEDIMENT DEPRESSION
@ OUTLET UNTIL STORMWATER
DETENTION TANK IS INSTALLED
DURING CONSTRUCTION
PROVIDE RUBBLE RUMBLE CROSSOVER
AT SITE ENTRY/EGRESS TO MINIMISE CONTAMINATION
FROM ENTERING ROAD AND STORMWATER SYSTEM
HATCHING DENOTES APPROX EXTENT OF COMPACTED FILL
FROM PLATFORM AND DRIVEWAY EXCAVATION AREAS
CONTRACTOR TO CONFIRM ALL DIMENSIONS &
LEVELS ON SITE PRIOR TO COMMENCEMENT
OF ANY WORK.
ALL CONSTRUCTION TO COMPLY WITH THE
AUSTRALIAN BUILDING CODE REQUIREMENTS
& RELEVANT AUSTRALIAN STANDARDS.
SEDIMENT STRUCTURES MAINTENANCE.
SEDIMENTATION CONTROLS OVER THE SITE ARE TO BE FULLY
FUNCTIONAL AT ALL TIMES. SEDIMENT CONTROL METHODS AND
SPACING T0 BE ADJUSTED TO SUIT ONSITE CONDITIONS. EROSION
AREAS ARE TO BE REHABILITATED UPON COMPLETION OF EARTHWORKS.
ALL STORMWATER OUTLETS AND CHANNELS TO BE STABLE AND WELL
MAINTAINED, THE CONTRACTOR IS FULLY RESPONSIBLE FOR ANY SILT
OR SEDIMENTATION PROBLEMS THAT MAY OCCUR OVER THE SITE. ALL
SEDIMENTATION CONTROL DEVICES TO BE MONITORED AND REGULARLY
MAINTAINED.
- m
GAG DESIGN
\ VEGETATION NOT INTENDED FOR RETENTION SHALL BE REMOVED
TO STOCKPILE FOR DISPOSAL. FILL MATERIAL SHALL NOT BE
PLACED AGAINST OR AROUND VEGETATION THAT IS TO BE
RETAINED. TOPSOIL IS NOT TO BE REMOVED FROM AROUND
VEGETATION THAT IS TO BE RETAINED. FILL MATERIAL IS NOT
TO BE PLACED IN HIGH EROSION RISK AREAS, SUCH AS
ADJACENT TO DRAINAGE LINES OR WATER COURSES. LAND
SHAPING OPERATIONS TO LEAVE EXPOSED SOIL IN A
ROUGHENED CONDITION TO ENCOURAGE INFILTRATION AND
MINIMISE RUNOFF. STOCKPILES ARE TO BE LOCATED AWAY FROM
AREAS SUBJECT TO CONCENTRATED OVERLAND FLOW AND
PREFERABLY ON FLAT GROUND. CONSTRUCT PERIMETER BANKS
OR CATCH DRAINS AROUND STOCKPILES AS REQUIRED AND AS
DIRECTED ON SITE BY ENGINEER. TRAFFIC TO BE LIMITED OVER
DRY EXPOSED SURFACES. EXPOSED SURFACES TO BE WATERED
AS REQUIRED TO ENSURE DUST CONTROL. WINDBREAKS TO BE
CONSTRUCTED AS DIRECTED ON SITE BY ENGINEER.
‘SITE MANAGEMENT _NOTES:-
THE EROSION AND SEDIMENTATION CONTROL PROGRAM IS TO BE
IMPLEMENTED AT COMMENCEMENT. VEHICLES AND PLANT TO BE
KEPT TO WELL DEFINED HAUL ROADS. CONSTRUCTION ROADS TO
FOLLOW NATURAL CONTOUR OF THE TERRAIN, WHERE POSSIBLE,
TO HELP REDUCE EROSION POTENTIAL. VEGETATION THAT IS TO
BE RETAINED TO BE CLEARLY DEFINED SO AS NOT TO BE
DISTURBED BY EQUIPMENT. TEMPORARY CATCH DRAINS
INSTALLED UPSLOPE OF EXPOSED SOILS AT THE END OF EACH
DAYS WORK AS NECESSARY AND AS DIRECTED ON SITE BY
ENGINEER. THE AREAS AFFECTED BY THE WORK SHALL BE KEPT
TO A MINIMUM. CONTRACTORS VEHICLE ENTRY AND EXIT POINTS
FROM THE SITE SHALL BE KEPT TO A MINIMUM. NO SEDIMENT
EITHER TRACKED OR RUNOFF PRODUCED WILL BE TOLERATED ON
PUBLIC ROADS. ANY MATERIAL FOUND ON PUBLIC ROADS IS TO
REMOVED IMMEDIATELY. CONTRACTOR IS FULLY RESPONSIBLE
FOR REMOVAL OF ANY SEDIMENT TRANSPORTED ONTO PUBLIC
Note:- All FILL to be compacted
and tested to Level 2 in
accordance with AS 3798
(commercial loading)
REVISION
POSIS DRIVEN
Z| 0ee IN{O
BATTERED AND SHAPED TO CARPARKING GRADE REQUIREMENTS WIRE OR I yw
SHEEL MESH NS
\S
~
EARTHWORKS & SEDIMENT CONTROL PLAN oe
DENOTES INDICATIVE SILT FENCE ALIGNMENT Sener sa
SCALE 1:200 (A3)
amen ene
BARRIER
NOTE:- \ ones
ALL EARTHWORKS AREAS Zz CO!
TO BE TOPSOILED, g !
SEEDED AND WATERED TO a v 700 MN.
i ENSURE MAXIMUM GRASS eal) |
COVERAGE AS SOON AS — 2tea Paxets om _|
POSSIBLE AFTER TSE Cl
COMPLETION OF WORK IN Note: CONRACIOR {0 REMOVE DEBRIS
TYPICAL FABRIC DROP VICINTY. es no keenen on
INLET PROTECTION DETAIL
a2 nT SEDIMENT FENCE DETAIL
EARTHWORKS & SEDIMENT CONTROL OOODO0OO000
} 1:200 (A3)
/Saint, Consulting
ENGINEERS
A.B.N. 15 096 410 909
ISSUE PRINTED: CADO01
010207-09
Page 18
—————
(c) THIS WORK IS COPYRIGHT AND THE PROPERTY OF Ri
PIED, REPRODUCED RETAINED ON OR USED IN
PURPOSE OTHER THAN THE SPECIFIC PURPOSE SET OUT HEREON WITHOUT WRITTEN PERMISSION
EXISTING CONCRETE FOQTPATN TO BE RETAINED
AND RECONSTRUCTED
\
\
\
REFER SITE PLAN FOR
STORMWATER DISCHARGE DETAILS
TT IS THE RESPONSIBILTY OF THE CONTRACTOR
TO CONTACT THE RELEVANT AUTHORITIES TO
CONFIRM THE LOCATION OF ALL EXISTING SERVICES
PRIOR TO COMMENCEMENT OF WORKS
ISSUE |_DATE
REVISION
PROPOSED
CARPARK
SCREENED WHEELIE BIN ENCLOSURE
TO COUNCIL STANDARDS
600 SQR FOX BCGPT
OR EQUIVALENT
PROPOSED DRIVEWAY LAYOUT
SCALE 1:100 (A3)
MiEAust CPEng Aust.No.29986
RPEQ No.1476 NPER-3 No.4046
Fay
NEW ENTRY DRIVEWAY
Or
TO BE RETAINED WHERE POSSIBLE
Renee
KERB DETAIL
40mm DEEP SAWCUT
OR CRACK-A-JOINT
WITH FILLER
. CRACK INITIATOR
DEFLECT MESH TO MISS
SAWCUT & CUT EVERY WATERPROOF. MEMBRANE
SECOND WIRE
AND SOmm SAND BED
SAWN JOINT - SJ
LEGEND:-
\
Sx
&
S DENOTES PROPOSED FINISHED SURFACE
LEVEL OF CARPARK TO BE CONFIRMED
TO SUIT FINAL BUILDING FLOOR LEVELS
THE LOCATION AND DEPTH
OF THE EXISTING WATER MAIN’
TO BE POTTED TO CONFIRM
ADEQUATE COVER AND PROTECTIO!
UNDER DRIVEWAY
PEDESTRIAN TRAFFIC ONLY AREAS
100 TK. CONCRETE SLAB
CONSTRUCTION JOINT DETAILS @ 6m CRS
SAWN JOINT DETAIL @ 6m CRS IN CARPARK
MIN CONCRETE COMPRESSIVE STRENGTH F'c 25 HP
AT 28 DAYS. STREMGTH Fe, te
(TO BE CONFIRMED ON SITE)
GRAVEL (CBR 30) 150 THICK
PAVEMENT DEPTHS MAY BE REDUCED
IF SUB-BASE CBR IS CHECKED.
DRIVEWAY LAYOUT & DETAILS
EXISTING CROSSOVER TO BE WIDENED
TO COUNCIL STANDARDS TO SUIT 6m WIDE
DRIVEWAY FORMATION
CONTRACTOR TO CONFIRM ALL DIMENSIONS &
LEVELS ON SITE PRIOR TO COMMENCEMENT
OF ANY WORK.
ALL CONSTRUCTION TO COMPLY WITH THE
AUSTRALIAN BUILDING CODE REQUIREMENTS.
& RELEVANT AUSTRALIAN STANDARDS
RPD
LOT 20 on P9315
PEREGIAN BEACH
FLEXIBLE PAVEMENT NOTES:-
150 THICK COMPACTED GRANULAR PAVEMENT
CBR4S TYPE 2.3 MATERIAL WITH HOT PRIME
OVER AND 25mm THICK ASPHALTIC CONCRETE
SEAL TO MANUFACTURERS RECOMMENDATIONS
ALTERNATIVE
CONCRETE PAVEMENT NOTES:-
MAIN DRIVEWAY
130 TK. CONCRETE SLAB - F82 MESH IT).
CARPARK AREAS
100 TK. CONCRETE SLAB - F72 MESH (T).
~ F62 MESH (T).
/saint, Consulting snc
LL ENGINEERS
STANLEY STREET, NAMBOUR Q)
4560. 456
[email protected]
AT
FOR
_ O9O0000000
ISSUE PRINTED: CADO01
010207-10
Page 19
(C)_THIS WORK IS COPYRIGHT AND THE PROPERTY OF ROY K. SAINT PTY. LTD. IT MUST NOT BE COPIED, REPRODUCED RETAINED ON OR USED IN ITS ENTIRETY OR IN PARTS FOR ANY PURPOSE OTHER THAN THE SPEC
PURPOSE SET OUT HEREON WITHOUT WRITTEN PERMISSION
CARPARK AREA
HIGH LEVEL OVERFLOW FROM GPT 9 _|
|
|
ROCLA or FOX BGPCT OR EQUIVALENT UNIT
150¢ UPVC
GRADED @ 1in100
TO DETENTION TANK
water level varies
1506 UPVC
GRADED @ 1in100
FROM CARPARK
5000 LITRE
NON-POTABLE
DETENTION TANK
150¢ UPVC
NOT TO SCALB
100¢ UPVC
LOW FLOW OUTLET GRADED @ 1in100
FROM DETENTION TANK
STORMWATER TANK
SCHEMATIC PLAN
1506 UPVC
HIGH LEVEL OVERFLOW
1
BOUNDARY
DRAINAGE EMT
TO BE CONFIRMED
BY TOWN PLANNER
OVERFLOW DISCHARGE FROM
ROOFWATER STORAGE TANK
NEW 600 SQR
FIELD INLET WITH
GRATED LID
OVER EXISTING PIPE
STORMWATER DRAINAGE NOTES
GENERAL
General: Provide stormwater drains to connect downpipes, surface drains, subsoil
drains and drainage pits to the outlet point or point of connection.
Downpipe connections: Turn up branch pipelines with bends to meet the downpipe,
finishing 50 mm (nominal) above finished ground or pavement level. Seal joints
between downpipes and drains.
Tolerances: Comply with the Pipeline tolerances table. These tolerances are conditional
on falls to outlets being maintained and no part of a pipeline being at less than the
designated gradient.
Pipe Materials
Stormwater pipe to be F.R.C. or U.P.V.C. class SH in accordance with AS3500.3
Connection to kerb to be galvanised RHS in accordance with AS1074 with minimum
coating mass of 500g/sqr.m
Identification
Lay a detectable strip or plastic tape in the trench after pipelaying, testing and initial
backfilling.
Pipe underlay
General: Bed piping on a continuous underlay of bedding material, at least 75 mm
thick after compaction. Grade the underlay evenly to the gradient of the pipeline.
Chases: If necessary, form chases to prevent projections such as sockets a flanges
from bearing on the trench bottom or underlay.
Pipe surrounds
General: Place the material in the pipe surround in layers 200 mm loose thickness,
and compact without damaging or displacing the piping.
Anchor blocks
If eceanaeyy provide anchor blocks which restrain lateral and axial movement of the
pipelines at junctions and changes of grade or direction.
Encasement
General: If necessary, encase the pipeline in concrete at least 150 mm above and
below the pipe, and 150 mm each side or the width of the trench, whichever is the
greater.
Concrete: Grade N20 to AS 1379.
Pipe depth
Provide the following minimum clear depths, measured to the crown of the pipe,
where the pipe passes below the following elements:
- 100 mm below formation level of the avemen kerb or channel.
- 100 mm below the average gradient of the bottom of footings.
- 450 mm below the finished surface of unpaved ground.
Jointing
At junctions of subsoil pipes provide tees, couplings or adaptors to AS 2439.1.
Trench width Minimum 450 mm.
Pipe underlay
General: Grade the trench floor evenly to the gradient of the pipeline. If the trench
floor is rock, correct any irregularities with compacted bedding material. Bed piping
on a continuous underlay of bedding material, at least 75 mm thick after
compaction. Lay the pipe with one line of perforations at the bottom.
Chases: If necessary, form chases to prevent projections such as sockets and flanges
from bearing on the trench bottom or underlay.
Pipe surrounds
General: Place the material in the pipe surround in layers 200 mm loose thickness,
and compact without damaging or displacing the piping.
nee of overlay: .
- To the underside of the bases of overlying structures such as pavements, slabs
and channels.
- To within 150 mm of the finished surface of unpaved or landscaped areas.
ISSUE DATE
GAG DESIGN
Sai
nt. Consulting
ENGINEERS
A.B.N. 15 096 410 909
MiEAust CPEng Aust.No.29986
RPEQ No.1476 NPER-3 No.40467
QBSA Lic.No. 16080
} STANLEY STREET, NAMBOUR QLD. 4560. 4564
PHONE : (07) 54412233 FAX : (07) 54763218
roy@saintconsutting. org
AT
FOR
STORMWATER MANAGEMENT DETAILS
OQOOOO0O0O
= N.T.S. (A3) ISSUE PRINTED: CADO01
inc No.|010207-11
Page 20
THIS WORK IS COPYRIGHT AND THE PROPERTY OF ROY K SAINT PTY. LTD. IT MUST NOT BE COPIED, REPRODUCED RETAINED ON OR USED IN ITS ENTIRETY OR IN PARTS FOR ANY PURPOSE OTHER THAN THE SPECIFIC PURPOSE SET OUT HEREON WITHOUT WRITTEN PERMISSION NOTES GENERAL : These notes and structural details are to be read FOOTING DIMENSION TABLE in conjunction with the designer's drawings and TOTAL HEIGHT ve specification associated with this project. OF RETAINING 8 BARS FOUNDATION Footings have been designed in accordance 1000 800 NiZ with AS2870-1996 and to be confirmed by foundation 1200 900 N12 investigation report. 1400 1000} N16 All foundations to be confirmed by geotechnical consultant prior to placement of foundation 1600 1100) N16 reinforcement. Minimum safe bearing capacity 1800 1300} N16 for all footings to be 100 kPa. 2000 1400] N20 ENGINEER TO BE CONTACTED IF CONCRETE : (1-50km from coast) WALL HEIGHT EXCEEDS TABLE 1m HIGH HANDRAIL WITH Workmanship and materials shall be in accordance BALUSTRADE FIXED TO TOP with AS 3600-2001. Concrete shall have the OF WALL TO MANUFACTURERS following properties: — DESIGN & SPECIFICATIONS CARPARK Bond beams, Retaining walls:—F’c=20 MPa at 28 x days, 10 nominal SN agg. 200 slump a All concrete shall be moisture cured for (7) days after pouring, by an approved method. REINFORCEMENT Reinforcement grade designated as follows:— ‘R’ Denotes round mild steel bar, Grade 500 "N’ Denotes high yield deformed bar, Grade 500 "SL’ Denotes welded fabric, Grade 500 GEOFABRIC ‘Ww’ Denotes hard drawn deformed wire, Grade 500 MEMBRANE GRAVEL SCREENINGS REFER TABLE MINIMUM CLEAR CONCRETE COVER:— Element | Formed and| Formed and |With earth sheltered exposed to as form location weather/earth| Footings = 65 75 Columns 40 50 75 N12 © 400 CTS 55 INSIDE COVER 7 ~ WATER PROOF SEALANT TO BACK OF WALL = N12 @ 400 HORIZONTAL REINFORCEMENT —+ +H- MINIMUM REINFORCEMENT LAPS:— Member] Lap Member | Lap 200 SERIES FULLY CORE FILLED "H’ PATTERN BLOCKWORK —, - 100 AGG. DRAIN N12 350 N32 2125 RETAINING WALL WITH DISCHARGING TO GRATED PIT N16 600 SL8T™ | 650 CLEANOUT AT BASE 3 WITH FROG FLAP OUTLET N20 800 MESH | 425 end (MIN 0.5% GRADE) N24 1200 225 side 7 \ Lt N28 1650 Wea RETAINING WALL HEIGHT 2m MAX. BLOCKWORK All workmanship and materials shall comply to AS 3700-1998 "Masonry Structures Code” External blockwork face to be coated with a suitable 7 ” waterproof coating in accordance with AS 2311. 250 'V’ BARS © 400 CTS wots oh Mortar types shall comply with AS 3700-1998 and amendments. Mortar types shall be :— ‘V’ STARTER BARS LOCATION IN BUILDING MORTAR MIX @ 400 CTS Cement Lime Sand REFER TABLE Damp proof course and B — REFER TABLE load bearing walls 1 1.0 6.0 + Non-load bearing ext. wall 1 1.0 9.0 Non—load bearing int. walls} 1 1.0 9.0 SITE PREPARATION Br Ng feria in eect MASONRY RETAINING WALL DETAIL for commercial and residential developments. N.T.S. = RETAINING WALL DETAILS GAG DESIGN _N.T.S.(A3) | ISSUE PRINTED: CAD001 MIEAust CPEng Aust.No.29986 | . } . (Saint, Consulting sancis\“- a —~ i. OQOOOOOOO0O ENGINEERS + STANLEY STREET, NAMBOUR QLD. 4560. 4564 ‘ 7 + = ABN. 15096 410 909 PHONE : (07) 54412233 FAX : (07) 54763218 IRAWING N a ISSUE __ DATE REVISION [email protected] FOR
Page 21
APPENDIX B EMAILED CORRESPONDENCE RE: WATER MAIN SAINT CONSULTING ENGINEERS
Page 22
Simon Dwyer From: Roy Saint ([email protected]} Sent: Tuesday, February 20, 2007 10:43 AM To: GRAHAM GREEN; Simon Dwyer Subject: FW: 010207 proposed MCU Water main location Follow Up Flag: Follow up Flag Status: Completed Simon please note the council note and I have sent advise to Graham to edit and note on th plans as well. Roy Saint From: John Fallon [mailto:[email protected]] Sent: Tuesday, 20 February 2007 10:06 AM To: [email protected] Cc: Lyn Pearce e~ 010207 proposed MCU Water main location oy, it is suggested that prior to construction, the water mains location and depth be confirmed. This can be done by Council or a Surveyor. This may only be necessary if there are major earth works at the water main location. The reason for the original request was that there no cross sections submitted with the proposal. Regards John John Fallon Water and Sewerage Asset Management [email protected] Noosa Council ph 07 54495306 fax 07 54471062 9 Pelican St. Tewantin Qld 4565 NOD32 2070 (20070219) Information is message was checked by NOD32 antivirus system. p://www.eset.com
Page 23
APPENDIX C STORMWATER EASEMENT DOCUMENTATION
Page 24
[ oo
a
x lo
~ eo.
[a ge:
psd re
16 r
: IF
suéa
96
oH B10814
PLAN MUST BE DRAWN WITHIN BLACK LINES
CTT VOR IO Assets Ale eueE IO Lene ener
arogtt
xcH
850231
: tot E isan Easement 2-Smetres wide
i for Orainage Purposes
: [NOOSA WaPPING & SURVEYS BFF CTO
roam conte angi cee Corny nies acme me | PLAN OF lot & pansy WEYBA
SET Tes Coase pptinainme ey . country March
: 3 BNL Reed Surveyor in Lot 96 on MCH 810611 tonuocane DEREGIAN BEACH
: Y a pocmen eh toe socal autromte Noosa Shire Councit
: ay" vo ued tree ater Gympie
2 eenwe Seer, (ORIGINAL LOT 76 Re HAVE mICOTDS GOREN tema reco
Orci wcniouN | MAP Rte SCAZ | PLEA] ENDORSED [ArGISTERNG Onst|
wm Grvpgye |CHBVIC® | gscS-33226) CRO plan 850231
owrseee PANE lnch arcen| 95¢§-a2291| 9% Brisbane 3
0 ' 2 a “ 5 6 ? a s 10 cm CROWN COPYRIGHT RESERVED: Pet WS TUUDOM OF SURVEYORS AUT TRALA SOULENSLANO Crnsiaa
1 AUTHOMNTY UCEAEE Maebtm BT gg oe
Page 25
700436671 VO REGISTERED Recorded Date 06/01/1995 10:49 Page 1 of 4
EEEIENARTE 95co17s99s
BE 640 ~——_ EASEMENT a
a
4 {EASE NO. 21/5278 ar
7 vw
t BLD STAMP DUTY — BNE
; How ESTATE (3) __ NOT APPLICABLE EPnIyOe WUEAIE4C.
: OR INTEREST $4. SCONE
: BEING BURDENED
1 IS HELD
GRANTEE (4) "OOUNGIL OF THE SHIRE GF NOOSA,
@ i DESCRIPTION (5) VOKME FOLIO COUNTY PARISH DESCRIPTION y
OF SERVIENT *PART OF ’ 7 Lor E IN Lor 96
TENEMENT 77a MARCH WEYBA ON MCHB10611 ON CP8SO231
2, 253% or
MORTGAGES, (6) — NIL
ENOUMBRANCES Z
ETC.
CONSIDERATION (7) 51.00 and in consideration of tha benefits following from the Easement
to the Grantor
[,) eso Hee Deana NO TE GARICR NO TE AY THE GRANTEE THE
EASEMENT HEREIN DESCRIBED AND THE GRANICR AND THE GRANTEE HERESY COVENANT
WITH EACH OTHER IN TERMS OF THE # SCHEDULZ HERETO.
19) si@eD Tas on ow — wey
Mae ra
REGISTERED
19 JUN 1985
By-
comet ee oes
re enema te
Lnitecn ena
® The State of Queensland (Department of Natural Resources and Mines) 2006
Page 26
peeres
Sa AL atari
A
g
i
B
i
é
3
zt
B
|
:
i
{
i
i
‘.
i
}
3
Page 27
“A
f / N,
4
/
/
re
ANDS
rm
4
MEN
EPAR
F LAND
oo
Ct
Office:
Sunshine Cuast Region
Gubwalture Land Service
Centre
Level 5. Cabootture Park
Your Ref: 8/27/Adnun
Our Ref: NAN 000667 & 668 NEL:TYH { ike
tI
14 December 1998
Chief Executive Officer
Noosa Shire Council
DX 41952
NOOSA .
Dear Sir
RE: PROPOSED EASEMENTS FOR STORMWATER DRAINAGE
PURPOSES iy
Shopping Centre I refer to your tetter of 13 July 1994 in respect to the above and have to
King Street advise that Easements as proposed in terms of the draft agreements
Cabualture submitted will be allowed provided:
oe 1080 1. . A copy of the duty registered plan of Survey of the Eascment area
Caboolture Q 4510 . ‘is inserted in each of the original and duplicate Easement
. - documents.
DX 40411 “
Caboolture
Contact:
Mr N Hore
Phone No:
(074) 953 499
Fax No:
(074) 957 758
2. Reference to the Land Act on the Recital Page is to be amended by
deletion of “ - 1989".
3. ftem (5) of the Agreement over SLS2779 - Description is to be
amended to read Lot D in Lot 74 on Plan MCH 3786 on Plan
MCH 807765.
4, The relative Instsumens of Lease of Special Lease No‘s 52778 and
52779 are lodged with the Easement agreements together with the
required registration fees.
When lodging the documentation at any Lands Department Land Service
Centre with a document lodgement facility enclose the attached copy of
this letter bearing the signature of the authorised officer confirming the
agreement of the Minister for Lands to the grant and registration of this
Easement.
Yours faithfully
Yarforer/ Kenic! SOHN HORE
Senior Land Ofi
as Delcgate@{ ire Minister for Lands
Bu a “We
¥or: Martin Holmes
Acting Regional Director
Used in these records
06/0718 - Response to request for further information [As Published]Related documentApplication case desk ↗
About this file
- File size
- 10.2 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.