(c) THIS WORK |S COPYRIGHT AND THE PROPERTY OF ROY K. SAINT PTY. LTD. IT MUST NOT BE COPIED, REPRODUCED RETAINED ON OR USED IN ITS ENTIRETY OR IN PARTS FOR ANY PURPOSE OTHER THAN THE SPECIFIC PURPOSE SET OUT HEREON WITHOUT WRITTEN PERMISSION
PREFABRICATED TIMBER ROOF TRUSSES @ 900 CTS
TO MANUFACTURERS DESIGN & SPECIFICATIONS STAIRS & BALUSTRADES
1. STAIRS SHALL BE CONSTRUCTED TO THE REQUIREMENTS OF BCA PART
EXISTING ROOF FRAMING TO BE RETAINED IF POSSIBLE 3.9.1 ‘ °
AND NEW ROOF PITCHED OVER TO MANUFACTURERS
PROVIDE R2.5 MINIMIN ROOF INSULATION DESIGN & SPECIFICATIONS 2. STAIRS SHALL HAVE A MAXIMUM RISE OF 190mm. MINIMUM GOING OF 240
TO CEILING SPACE TO MANUFACTURERS SPECIFICATIONS 2% 50° == AND WITH A SLOPE RELATIONSHIP (2R+G) OF 550min. TO 700max
ap Oop a 3. TREADS AND BALUSTRADES MUST BE CAPABLE OF ALLOWING A 1259
“One, Ln = SPHERE THROUGH OPENINGS.
Ry p XY =I ;
= 4, BALUSTRADES TO STAIRS MUST NOT BE LESS THAN 865mm HT MEASURED
Ly by Pp, & _ COLORBOND ROOF SHEETING FROM THE STEP NOSINGS, AND 100mm HT. AT
Sint Bi 70 OWNERS CHOICE LANDINGS OR BALCONIES,
ap a
S
a 90x70 F 11 HANDRAIL
|S
450 EAVE 450 EAVE S\= DOWEL BALUSTERS
T.B.C. SZ T.B.C. a! & TO MATCH EXISTING
2 a by REFER FLOOR FRAMING PLAN AT 125mm MAX. CTS
32 =
S
| o>
@ PROVIDE FIRE RATED CEILING LINING
BETWEEN UPPER AND LOWER AREAS 90x90 F 11 END AND SOM5.F-14
5 708.C.A. REQUIREMENTS | INTERMEDIATE BOTTOM RAN
eo a POSTS
@ = Ss !
~ S EXTERNAL CLADDING TO re
SS OWNERS CHOICE |_
3 a 250x75 F.14 UNSI
z TREADS MAX. 14
ae or eee ai eel ae oe
TT Li “Uy = 250x50 F.14 UNSEAS.
LJ TIMBER STRINGER m
MAX. HOUSING FOR TIMBER
REFER FOOTING PLAN FOR DETAILS means
TYPICAL SECTION 2R+G=610 OK
Scale |: 100 (A3) TYPICAL GOING.
cale I.
BE IN ACCORDANCE WITH THE B.C.A CLAUSE
TERMITE PROTECTION LL BE CONSTRUCTE ACCORDANCE W' THE
| a | TIMBER ELEMENTS LL BE IN ACCORDANCE W
2
PROVIDE TERMITE PROTECTION IN ACCORDANCE WITH AS 3660.01 | | RISER
— 2000 USING LICENSED CONTRACTOR. INSTALL A “PHYSICAL \ AND GOING MENSIONS in?
BARRIER” TO PERIMETER OF SLAB & TO ALL PENETRATIONS & “ | i
PART B SPRAY IN ACCORDANCE WITH AMENDMENT 8 OF BCA. a nel Fe icakcba
ATTACHMENTS TO BUILDINGS: ATTACHMENTS TO BUILDING, SUCH AS 600 310 | PUBLIC STARS DO = 95 BO 700 50
DOWNPIPES AND SERVICE PIPES SHALL HAVE A NOMINAL GAP, TO ad AEG b |
ALLOW CLEAR AND UNINTERRUPTED INSPECTION ACROSS THE | meshes. Sole “Satie
INSPECTION ZONE
1050 535 |
STRUCTURES SUCH AS STEPS, VERANDAHS, PORCHES, ACCESS 1200 615 | coed
RAMPS, CARPORTS, TRELLISES, DECKS, HOT WATER SYSTEMS, AIR \ ——-
CONDITIONERS, OR SIMILAR, WHICH ARE NOT PROVIDED WITH ONE OF 1350 690 | Boe
THE BARRIER SYSTEMS DESCRIBED IN THE |
AS 3660.1-200, SHALL BE SEPARATED FROM THE BUILDING BY A 1500 765 j j
GAP OF AT LEAST 25mm, TO ALLOW CLEAR AND UNINTERRUPTED t J
VISUAL INSPECTION ACROSS THE INSPECTION ZONE. 1800 920
WHERE ATTACHMENTS OR STRUCTURES, AS OUTLINED ABOVE, ABUT 2100 1070 SHADE WIDTHS for Note: dv PRIVATE STARS ARE
A BUILDING AND THERE IS NO CLEAR GAP, THEN A BARRIER SHALL
BE PROVIDED TO THE ATTACHMENT, REGARDLESS OF THE SIZE OF 2400 1225 OPENINGS © STAIRS IN A CLASS 1.0 10 BUILDING
THE ATTACHMENT. 4 STAIRS IN A SOLE-OCCURANCY UNIT IN A CLASS 2 BUILDING OR CLASS 4 PARE AND
> IN ANY BUILDANG, STAIRS WHICH ART NOt PART OF A REQUIRED Exit AND tO WHICH THE
BRIDGING AND BREACHING. PUBLIC DO NOt NORMALLY HAVE ACCESS,
WER: Al iT TR' Ri XTURI R > THE GOING IN TAPERED [READS «AS IN A CURVED OR SPIRAL STAIR IS MEASURED -
BARRIERS SHALL NOT BE BRIDGED BY STRUCTURES, FIXTU ES Of CONTRACTOR TO CONFIRM ALL DIMENSIONS & >
FITTINGS ATTACHED TO THE MAIN BUILDING ( E.G. HOT—WATER © ZTomm Wi rROM HE OUTER SIDE IF THE FLIGHT IS Loss fan
SYSTEMS, STEPS, VERANDAHS ACCESS RAMPS CLADDINGS, LEVELS ON SITE PRIOR TO COMMENCEMENT MES
CARPORTS, TRELLISES OR SIMILAR STRUCTURES), NOR SHALL THEY OF ANY WORK. > 270m FROM EACH SIDE. IF THE PLIGHT IS MOR MORE Wite,
BE BREACHED BY THE INSTALLATION OF SERVICE ENTRY POINTS, ALL CONSTRUCTION TO COMPLY WITH THE Soa At Ger nee a h AND WuSt BE NOt LEDS THAN
DOWN PIPES, AN ADDITIONAL SLAB, PATHWAYS, LANDSCAPING, AUSTRALIAN BUILDING CODE REQUIREMENTS
GARDENING, OR SIMILAR, UNLESS ADDITIONAL BARRIERS ARE USED & RELEVANT AUSTRALIAN STANDARDS.
TO DETER CONCEALED ACCESS BY TERMITES TO THE STRUCTURE.
. — TYPICAL SECTION == OOODDOO0OO0
GAG DESIGN ) | 1:100(A3) | ISSUE PRINTED: CADO001
. . MIEAust CPEng Aust.No.29986
Saint Consulti n RPEQ No.1476 NPER-3 No.40467 eG
{ J g QBSA Lic.No. 16080
ENGINEERS 1 STANLEY STREET, NAMBOUR QLD. 4560 4561
2 * A.B.N. 15 096 410 909 PHONE : (07) 54412233. FAX : (07) 54763218 DRAWING P 0 1 0207-07
ISSUE ___DATE REVISION — roy@saintconsulting org FOR 1
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
06/0718 - Response to request for further information [As Published]Related documentApplication case desk ↗