(C)_THIS WORK IS COPYRIGHT AND THE PROPERTY OF ROY K. SAINT PTY_LTD_ IT MUST NOT BE COPIED_ REPRODUCED RETAINED ON OR USED IN ITS ENTIRETY OR IN PARTS FOR ANY PURPOSE OTHER THAN THE SPECIFIC PURPOSE SET OUT HEREON WITHOUT WRITTEN PERMISSION
San eal (Seg Eee
1. This structure has been designed in accordance with the
current editions of the Building Code of Australio (BCA-96)
‘and the Queensland Building Act - Standard Building Law,
2. All building work shall comply with the current editions of
the relevant Australian and New Zealand Standards and other
documents as called up in the BCA-96.
3. Unless stated otherwise, all materials shall be as listed in
the Accredited Building Products Register.
4. The builder shall check and verify all dimensions, fixings,
fittings and finishes before commencement of works.
5. Reduced levels (RL’s) and ground contours as shown have
not been measured by the author of these documents and may
only indicate the approximate general shape of the terrain and
heights of the various building elements. Unless stated other—
actual accurate levels shall be determined either by the
builder or 9 land surveyor prior to commencement.
6. Written dimensions as show on the drawings take pre—
cedence. DO NOT SCALE DIRECT FROM THE DRAWINGS!. In the
event that questions arise, discrepancies or errors are
noticed, please do not proceed with the work without
requesting further instructions from the builder and/or the
building designer.
7. Construction must not vary from these drawings without
the written approval of the owner/s, licensed certifier and
the building designer.
8, Unless stated otherwise, these drawings have been prep—
ared either for client approval, planning approval or building
permit approval only. No responsibilty will be accepted by
the building designer for drawings or further construction (shop)
drawings prepared by others.
9. Any anchor rods/bolts and roof truss tie-down details
shown are for standard trusses only. The builder shall obtain
tie-down details for any non-standard trusses such as hips,
girders, valleys etc. from the truss manufacturer or struct—
ural engineer. This information shall be made available to
the Local Government or Licensed Certifier at the time of
lodgement of the Building Permit Application.
=\ *
10. Refer to the structural and/or geochemical engineering
report/s for footings and slab details not shown.
11, Unless stated otherwise, rainwater discharge either shall
be directed to the road kerb or dispersed within the prop—
erty boundaries to Local Government requirements.
12. TERMITE PROTECTION:
96 The building shall be protected from subterranean termites
by approved physical and/or chemical barriers in accordance
with AS3660.1. The precise method of protection shall be
determined by the owner/s and/or builder only after consult—
ation with a licensed pest control operator. This information
then shall be advised to the Local Government or Licensed
Certifier prior to, or at the time of lodgement of the
Building Permit Application.
TENNIS
COURTS
THEREAFTER, THE OWNER/S SHALL ENSURE that any physical
barriers are kept clear of garden beds and/or soil build up,
that any chemical barriers remain undisturbed and that annual
inspections (plus eradication os necessary) are carried out
throughout the life of the building by a licensed pest control
operator in accordance with AS3660.1.
RPD
LOT 20 on P9315
PEREGIAN BEACH
CONTRACTOR TO CONFIRM ALL DIMENSIONS &
LEVELS ON SITE PRIOR TO COMMENCEMENT
OF ANY WORK.
ALL CONSTRUCTION TO COMPLY WITH THE
AUSTRALIAN BUILDING CODE REQUIREMENTS
& RELEVANT AUSTRALIAN STANDARDS.
EXISTING SITE PLAN
SCALE 1:200 (A3)
sittin F EXISTING SITE PLAN ENO _ OYOOQOOOOOO
: { 1:200(A3) | ISSUE PRINTED: CADO01
GAG DESIGN - ) J | | is |
. . MiEAust CPEng Aust.No.29986,
( ENGINEERS 1 STANLEY STREET, NAMBOUR QLD. 4560 456 as
eR RLAK CRN U is PHONE ; (07) 54412233 FAX : (07) 54763218 } URA : 01 0207-01
[email protected] FOR
ISSUE | _DATE REVISION
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
06/0718 - Response to request for further information [As Published]Related documentApplication case desk ↗
About this file
- File size
- 10.2 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.