(c)    lighting;

(d)    signage and wayfinding;

(e)    minimising entrapment
       locations; and

(f)    building entrances, loading
       and storage areas that are well
       lit and lockable after hours.


Editor’s note—development should
reflect the principles of Crime
Prevention through Environmental
Design Guidelines for Queensland.
Lighting PO34                          AO34.1                                 Can be conditioned to comply
Lighting of appropriate intensities is Lighting of appropriate intensities is
provided to building entrances, provided            which      satisfies  the
carparks and pedestrian paths is requirements of Australian Standard
provided to maximise safety.           AS1158: Public Lighting Code unless
                                       otherwise specified in this Code.

                                         AO34.2                                  Can be conditioned to comply
                                         Recreation and open space areas are lit
                                         according to AS4282— Control of the
                                         obtrusive effects of outdoor lighting
                                         while still being a minimum 20 lux at
                                         footpath level.

                                         AO34.3                                    Can be conditioned to comply
                                         External lighting of a graduated
                                         intensity is provided which starts at a
                                         lower level of brightness at the
                                         perimeter of the site and rises to a
                                         higher level at the entrance to buildings
                                         or at the centre of the site.

                                         AO34.4                                 Can be conditioned to comply
                                         Lighting is directed onto the site and
                                         away from neighbouring properties.

                                     AO34.5                               Can be conditioned to comply
                                     Vandal­resistant lighting is used in
                                     publicly accessible areas.
PO35                                 AO35.1                               Complies
All property boundaries are clearly Boundaries are identified by such
identifiable with public and private means as:
spaces clearly defined.              (a)     fencing; or

                                         (b)    changes in surface materials or
                                                levels; or

                                         (c)    landscape treatments.


                                        AO35.2
                                        Loading and storage areas are well lit or
                                        can be locked after hours.
PO36                                    AO36                                      Complies
Sites containing utility installations, Security    fencing,   signage      and
substations,        telecommunications landscaping is provided to clearly
facilities, transport infrastructure or delineate private property and prevent
other infrastructure that pose a health unauthorised entry.
or safety risk are secure and maintain
public safety.
PO37                                    AO37                                      Complies
All premises and access routes are All premises are identified by the
Log in to download the original file

Noosa Plan Code Assessment.pdf · 354 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.