Council archive · source document
TPC 2653 - Change to Development Approval [As Published] · 51994.1147.02
SPANLINE COMPONENTS
SPANLINE ROOF PANEL
0.42mm GSS0 Hi TENSILE STEEL BASE
WITH COLOURWELD@ COATINGS
0.48mm 550 HI TENSILE STEEL BASE
WITH COLOURWELD® COATINGS
GUTTER SECTION
9.42 x 0.408 GSS0 ZINCALUME
WITH COLOURWELD@ COATINGS
REAR GUTTER
SPANLINE ROLL FORMED
REAR GUTTER
1.0.x 260.6300. ZINCALUME
WITH COLOURWELD® COATINGS
ROOF TO GUTTER CLIP
1.2mm THICK GALVANISED
STEEL
SPANLINE INSERT
1.0 x 0.330 G50 ZINCALUME
t
C Jk 23
UYU
&
SPANLIME ROLL FORMED «= g
GUTTER SECTION
4j
Bo
3000
J PRIOR TO WALKING ON ROOF -
NN, GUTTER FASCIA MAY BE
.
A TEMPORARY WALKWAY SHALL BE EVERY Im ON SIDES. ‘\
SUPPORTED ON PURLINS OR ROOF BEAMS
IN ACCORDANCE WITH AS 1562.1 - 1992 \
REQUIRED TO REPLACE ONE
SIDE FASCIA WHERE WATER
IS DISCHARGED INTO EXISTING
STORMWATER SYSTEM.
/- SUTTER CORNER 7 SEALED POP
/ RIVET EACH SIDE, SEAL ALL JOINTS.
L ROOF TO GUTTER CLIP. TEK ORIVE
/ 1Q SHEETING EVERY THRO SHEET &
“POP RIVET OTHER END TO GUTTER.
GUTTER SECTION
=
zl LC Ua
=| ROLL FORM BEAM ROLL FORM BEAM
SPANLINE ROLL FORMED BEAM = PROVIDE 2mm THICK
0,8 x 0.276 G300 ZINCALUME z <y MiOmm CUP HEAD BOL: SQUARE WASHER 10
WITH COLOURWELO@ COATINGS . SUIT BI
i b > NUT & WASHER. EAM WIDTH.
ak STEEL POST BRACKET b. a
jetta 10 FIX TO BEAM WITH 1/Mi2mm BE i Yomm SPACER TUBE
t— 2/M12nm BOLTS.
Tv CONCEALED CONNECTOR 1/10ram BOLT
SPANLINE ROLL FORMED BEAM | RHS SLEEVE T0 SUIT POST A
10 558 MCALIME @ Size, MIN. 75mm INTO POST. oa aS BRACKET oN PN
a“
6 w 44 x 35 HWF TEKS OR NUT io a ~N ; or ft POST FROM CHART
je £ BOLT TO METAL FASCIA BRACKET. POST FROM CHART~ 5] T Cv \
es ALTERNATIVE FIXING FOR TIMBER FASCIA ers Wt? ONABOL Spe]
75mm 117 TEKS AT RAFTER CRS. m r /M10 DYNABOLT
SPANLINE ROLL FORMED BEAM
1.0 4300. ZINCALUME Fs —? ~ 40 x Smm.FMS STEEL ANGLE 17M10mm BOLT we u 1/Mi0am BOLT OR
WITH COLOURWELD® COATINGS ee BRACKET, FIX WITH &/14 x 50 4/12-14-20 TEKS 4 /42-14-20 TEKS
TYPE 17 CLASS 3 TEKS OR
U Mi
CE Ec DER /Mi BOLTS TO METAL FASCIA. POST BASE BRACKET >10.0kN POST BASE BRACKET <10,0kN
post OPTIONS {cee reverse EXISTING GUTTER TO RESIST 1200 MAX CRS.
ee revers LEAKS DUE TO OVERFLOW. T US| A TI Al SEMB:
is i ify thot the design and details sh this side and th
FOOTING TYPE OPTIONS GENERAL FASTENERS DESIGN CRITERIA This isto certiy thot ine Ges bhe other side comply with the following codes: SPANLINE AUSTRALIA
AS 4055 - 1992 WIND LOADS FOR HOUSING . CNR. BANKSIA & BORONIA STREETS,
4 CAST POST INTO Roofing generally to 5/32 rivets or 12-14-20 AS 1664 - Hoy Deal REALE ACT 5g 1 ROOF BYRON BAY, N.S.W., 2481, (PO BOX 1006)
Ay alae ae gg y IFICATIO AS 1562.1 1992 DESIGN AND INSTALLATION OF SHEE g
jan i i WALL CLADDI ART 1;
HORHUM back channel, fascia Tek Screws with WIND CLASSIFI N 8 ee tae MT EEL STRUCTURES CODE CUSTOMER NAME & ADDRESS
gutter, beam Neoprene washers AS 3600 199% CONCRETE, STRUCTURES CODE
AS 4100 - 1
i S$ 1170 - 1989 PART 1 SAA LOADING CODE DEAD & LIVE LOADS
N2em@ tod Cycwne vette WTO COEFFICIENT Cp'n Ae 70 11989 PART 2 SAA LOADING CODE WIND FORCES
' . isfi teucture built i d ith these details i
J tostsin MAX. ROOF PANEL SPAN Fa cite tet aire orces resulting from o specifi selection of
FROM END z 2 Corner Caps & Fascias As most of these fixings basic wind velocity, terrain category and appropriate pressure coefficient. DISTRIBUTED & INSTALLED BY:
P 9 BEAM SPAN mm Certification is conditional upon the following:
° ° are fo me concealed or ' . No pedestrian loading is permitted ditectly on the roof sheeting.
ouched up rhe pop rive BEAM TYPE mm : e correct design criferia are selected.
L ay used is no less than 3mm . Astenbly used comply ite ne design fate cedures set out in the
anes ae mere Hea ees aan BASE FOOTING DATA B mm see anuals falta ny ,
T ING HART, Toma EMBEDNENT, fine . :
PLATE FULLY WELDED TO POST. | Post bracket to beam mm bolts ar Teks from chart TE Qo Ting DATA D mm These plans comply with the building code of Austratia PATIO COVER - ROLL FORM BEAM ~
Eantaic: TVOC ‘at
CanTaIT TVDE ‘RB’
ane vale weet
J.J. GLYNN BE F.LE: Aust
Lo
For & on behalf of Glynn Tucker Consulting Engineers RPEQ#I0.
Nrowinn No: R.B.100 DATE:10/10/2001
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
TPC 2653 - Change to Development Approval [As Published]Related documentApplication case desk ↗
About this file
- File size
- 2.3 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.