39 Lorilet 05 Bushfire Hazard Overlay Code
Performance outcomes Acceptable outcomes
fire fighting appliances (e.g. by avoiding
battle-axe/hatchet lots and long narrow
lots with long access driveways to
buildings);
3. where more than 2500m², achieves Not applicable.
setbacks from hazardous vegetation in line
with Bushfire Attack Level 29 requirements
as per AS3959; and
4. is designed so
that buildings and structures are sited in Not applicable.
locations of lowest hazard within the lot
and elements of the development least
susceptible to fire are closest to the fire
hazard.
Firebreaks and fire access tracks
PO8 AO8.1 No change to the road layout.
Firebreaks and fire access tracks provide: Where development involves the creation of a new road
and lots, a firebreak is provided by providing a cleared
1. adequate access for fire fighting and road reserve not less than 20 metres wide and maximum
other emergency vehicles; and gradient of 12.5% around the perimeter of the
2. adequate access for the evacuation subdivision, between the created lots and surrounding
of residents and emergency vegetated lands.
personnel in an emergency situation.
OR
AO8.2 Not applicable.
Fire access tracks are provided between the created lots
and surrounding vegetated land that:
1. have a cleared minimum width of 6 metres;
See the original