Skip to the record
NoosaWatch™: The source of truth.

Council archive · source document

Development Application for Permit to Damage Vegetation IDAS Forms 1 & 6 - OPW12/0568

of 27

Text shows just the words. Original shows the document exactly as it was published.

Check the original when the exact wording matters.

Very large file (14.4 MB): the original may take a few minutes to open or download. The page text below is quick to read.

DDD
                                                                               Confirmation
                                                                                                Method of lodgement
                                                                               of lodgement

Applications for operational works involving stormwater drainage

drawings showing:
.
    existing and proposed contours
.
    drainage locations, diameters and class of pipe, open drains and
    easements
                                                                                Dconfirmed
.   manhole location, chainage and offset or co-ordinates and inlet and
    outlet invert levels
.   inlet pit locations, chainage and offset or co-ordinates and invert and
    kerb levels

Applications for operational works involving water reticulation


drawings showing:
.   kerb lines or edge of pavement where kerb is not constructed
.   location and levels of other utility services where affected by water
    reticulation works
.
    pipe diameter, type of pipe and pipe alignment
.  water main alignments
                                                                                D confirmed
.  water supply pump station details (if applicable)
.   minor reservoir details (if applicable)
.  conduits
.   location of valves and fire hydrants
.   location of house connections (if applicable)
.   location of bench marks and reference pegs

Applications for operational works involving sewerage reticulation

drawings showing:
.   location of all existing and proposed services
.  location of all existing and proposed sewer lines and manhole locations
.  location of all house connection branches
.kerb lines or edge of pavement where kerb is not constructed
.
 chainages
                                                                                Dconfirmed
.
 design sewer invert levels
.
 design top of manhole levels
.
 type of manhole and manhole cover
.
 pipe diameter, type of pipe and pipe alignment
.location of house connections
                                (if applicable)
.sewer pump station details (if applicable)


Applications for operational works involving street lighting

drawings showing:
.  location of all light poles and service conduits
.  location of all other cross road conduits
.
   type of wattage and lighting
                                                                                Dconfirmed
.
   any traffic calming devices
.  additional plans for roundabouts and major roads (if applicable)
.  details of any variations to normal alignment
.  details of lighting levels




                                              Building and operational work assessable against a planning scheme IDAS form 6
                                                                                                              -




                                                                                              Version 1.018 December 2009

Used in these records

About this file

File size
14.4 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Development Application for Permit to Damage Vegetation IDAS Forms 1 & 6 - OPW12_0568.pdf · 14.4 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.