Council archive · source document
Jellyfish Compliance with SQIDEP · MCU15/0122
Attached to the e-mail MCU15/0122 - Response to Information Request -Stormwater (Jellyfish compliance) Email 3 of 3.
Sampling Procedures and Techniques
Automated Sampling Composite samples on a flow weighted basis Two ISCO 6712 Automatic Samplers (one each
PASS
to measure influent and effluent)
Minimum Number of Aliquots 8 per event* (see discussion points in SQIDEP) All events except 3 achieved 8 or more
samples. Number of samples collected was
automatically selected based on the intensity
of the rainfall received. However, It may not
add to the scientific consideration of PASS
performance to omit samples on the basis of
too few aliquots where all other indicators
indicate a qualifying storm event. (see
discussion in SQIDEP, and Appendix A)
Hydrograph coverage Indicative 50% (importantly the rising and falling Peak and median rainfall runoff volumes were
hydrograph components should be included in testing, recorded. Additional data for hydrograph can
PASS
and dependent on catchment and rainfall patterns, be provided on request (refer to Appendix C)
multiple peaks should be accounted for).
Manual Sampling Only for constituents that transforms rapidly, require Sample collection, handling and transport
special preservation or adhere to bottles, or where were undertaken in accordance with AS/NZS
compositing can mask the presence of some 5667.1:1889 (samples were returned to lab PASS
contaminants through dilution. See Section 10 for within 24 hours of collection, etc)
details.
Sampling Location As identified and agreed in the submitted QAPP. Commercial site at Ipswich (see Appendix A) PASS
Analytical Methods Various (refer to agreed EPA reference document) Sample collection, handling and transport
and/or Standard Methods (for organic, inorganic and were undertaken in accordance with AS/NZS
biological analysis as required) 5667.1:1889. Testing was conducted in PASS
accordance with APHA (2012) with various
methods (refer table 1 of Appendix A)
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Jellyfish Compliance with SQIDEP.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.7 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.