PROVIDE ON SITE BIO RETENTION SYSTEM WITH THE FOLLOWING PARAMETERS:

PROPOSED FOOTPRINT AREA: 42sqm

DEPTH OF FILTER LAYER: 400mm

LEVEL OF OVERFLOW WEIR: RL4.520

CONMUNAWN>

EXTENDED DETENTION DEPTH: 250mm

DEPTH OF TRANSITION LAYER: 100mm

DEPTH OF DRAINAGE LAYER: 200mm — 400mm
CATCHMENT AREA HARDSTAND: 806sqm

LEVEL OF SURROUND GOUND: FFL4.570

. SURFACE LEVEL OF FILTER LAYER: FFL4.320

10. INVERT LEVEL OF OVERFLOW CHAMBER: IL3.220
11. MINIMUM REQUIRED FILTER MEDIUM SURFACE AREA: 18sqm (PROPOSED: 22.5sqm)
12. THE WHOLE TRENCH REQUIRES AN IMPERVIOUS LINER

REFER DETAILED DESIGN ON DRAWING 28

‘a
— t

existing
street
tree
EB 60
4
3

64-3

CS

CS

C

exis TING

stre

t

arive

FALL
7.100

\

PROVIDE ON SITE STORAGE
FOR PEAK FLOW MITIGATION.
PROPOSED ARE 2 off
CONCRETE, TRAFFICABLE
TANKS BELOW SLAB WITH AN
EFFECTIVE STORAGE VOLUME
OF TOTAL 10,000L

ACCESS HATCH REFER TO:
MANUFACTURER

path
continues

   
 
 
 
  
 

\

FFL4.570

\

REFER TANK ASSEMBLEY

DETAIL

8

OY

1L4.215
Lo

 

 

 

 

 

type 1

FFL5.100

warehouse

 

 

 

 

 

coms
fe
D>

 

 

staff
room

 

 

 

 

 

 

opening

FFLS5.100

trade related sales

 

 

   

auto doors

 

 

TOP OF TANKS RL4.545
BOTTOM OF TANKS RL3.245

EXISTING FIELD INLET
900X900 % REFER VDM
SL4.565
IL2.554
MAKLE GOOD TO BE THE BIO
RETENTION SYSTEM BYPASS
CHAMBER. REFER DETAIL

 

 

 

 

/ 9225 TO
OVERFLOW
IL4.520 \ CHAMBER

driveway \

 

 

 

-+- FFL5.050

NG
STORMWATER PIPE
3
USIL2.554

 

 

 

 

 

foyer

type 4

FFL5.100

showroom

 

flexi desk

 

 

 

ox;

“Ysadled we

 

circulation
space

   

power

 

 

 

 

 

 

 

 

 

 

 

 

$F]

 

 

 

NOTE:

ALL EXISTING SERVICES HAVE BEEN PLOTTED
FROM COPIES OF THE DRAWINGS PROVIDED
BY VDM ENGINEERS AND SHALL BE
CONFIRMED PRIOR TO CONSTRUCTION. ALLOW
FOR ALL COSTS OF SURVEY.

DISCLAIMER — ENSURE ORIGINAL SIZE DRAWING IS USED
FOR ASSESSMENT, TENDERING AND CONSTRUCTION.

 

[Amd Description Date

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PO Box 181

Moffat Beach, QLD, 4551
email: [email protected]
PH: (07) 5491 4333

AHSCA

FX: (07) 5491 4233

B_ | NEW ARCHITECTURAL LAYOUT 11-09-14
A_|INVERT LEVEL CHANGED; NOTES CHANGED 03-06-14
Issue Notes Date

For Development Approval] X 21-05-14
For Building Approval x 21-05-14
For Tender

For Construction
As Constructed

E Hydraulic 3:

~ >)

contact: Reinhold Koenning MiEAust RPEQ No 7023

 

 

 

 

 

 

 

 

 

CLIENT :
WILSON CLARK CONSTRUCTIONS
ARCHITECT :
LL COOL ARCHITECTURE J
(PRosect: 10/100 RENE STREET Y
NOOSAVILLE
DRAWING TITLE:
\
STORMWATER
MANAGEMENT
PLAN
Design| RK. | checked | Cro [Date 21-05-14 | Dwg, No. AMD.
\ Scale: 1: 100 ON At UNo.| 2 of 6 2864—-OP2 By

 

 

RPD:— LOT 10 SP 230643

 

 

Used in these records

About this file

File size
8.6 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Collated Planning Report.pdf · 8.6 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.