Council archive · source document
Collated Planning Report · MCU14/0077
Attached to the e-mail MCU14/0077 & OPW14/0324 Industrial business Type 1 & Retail business Type 4.
Original PDF page 87, section 1. The text section number identifies this passage in the reader.
Application for a Development Permit for Material Change of Use to establish an Industrial Business, Type 1 Warehouse and Retail Business, Type 4 Showroom (Trade Related Showroom, Plumbing Supplies) and Operational Works (Stormwater Drainage, Landscaping, Car Parking and Access Driveway), on land identified as Lot 10 on SP230643, situated at 10/100 Rene Street, Noosaville Qld 4566 DRIVEWAYS AND CAR PARKING CODE Specific Outcomes Probable Solutions How does the proposal comply with the Overall Outcome/s or Specific Outcome/s? 14.113 General O1 Vehicular access does not adversely S1.1 Vehicular access is located and designed in Complies. impact on safety, capacity and operations accordance with AUSTROADS-Guide to Traffic of the existing or planned road network, Engineering Practice requirements for sight distance The proposed development does not require an additional driveway the proposed driveway, cycleways or and Section 3 of AS2890.1 Parking Facilities; crossover onto the road network as the one (1) existing access pedestrian pathway systems. AND driveway from the formed road abutting the northern boundary is S1.2 Only one footpath crossing is provided; adequate to service the proposed development. Furthermore, the AND location of the existing access driveway along the road network ensures S1.3 Driveways, other than within any setback have a that safe ingress and egress can be achieved. maximum grade in accordance with Section 3 of AS/NZS 2890.1 O2 Driveways and crossovers— S2.1 Design of the driveway across the footpath is in Not applicable. a) are suitable and safe for their intended accordance with Council’s Standard Drawings 9002 or use; and 9005 as appropriate for the particular type of A new driveway crossover is not required to facilitate the proposed b) match Council infrastructure. development as annotated on the drawings; development. AND S2.2 Driveways are designed and constructed in accordance with Council Standard Drawings 9014, 9019, 9020, 9021, as appropriate for the particular type of development as annotated on the drawings; AND S2.3 The change in grades in the driveways and ramps is in accordance with Section 3 of AS2890.1 Parking Facilities. O3 In commercial zoned areas, the S3.1 Design of multi-tenanted developments in Not applicable. number of driveways across pedestrian commercial zoned areas include shared driveways and footpaths is minimised. parking areas; The existing vehicular access arrangements to the subject site will be AND maintained by the proposed development. S3.2 Driveways are located so they abut existing driveways of adjoining development where practicable and reciprocal easements are created to reduce the sealed driveway width.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Collated Planning Report.pdfRelated documentApplication case desk ↗
About this file
- File size
- 8.6 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.