Council archive · source document
Collated Planning Report · MCU14/0077
Attached to the e-mail MCU14/0077 & OPW14/0324 Industrial business Type 1 & Retail business Type 4.
Original PDF page 94, section 1. The text section number identifies this passage in the reader.
ensures— No haulage of material will occur to or from the subject site.
a) minimal disturbance to
neighbouring properties and
properties along the haulage route;
and
b) Council’s road infrastructure
including pavements is not
adversely affected.
O8 Extent of earthworks S8.1 All earthworks, including cut and fill batters, Complies.
Earthworks are contained within the subject retaining walls etc are contained within the subject
property. site. All earthworks necessary for the proposed development will be
contained with the boundaries of the subject site.
Sloping sites Not applicable.
O9 On sloping sites, excavation or filling are S9.1 Cut or fill is less than 2m in depth relative to
designed to maximise the use of natural the natural ground surface. The subject site is relatively flat.
slope and minimise the need for cut and fill.
Environmental protection Complies.
O10 Earthworks minimise any adverse No solution provided
impact upon groundwater, watercourses, The earthworks required will not be to a depth to impact on
drainage lines, wetlands, and native groundwater.
vegetation
The subject site is not located nearby any watercourses, drainage
lines, wetlands or native vegetation.
Dams S11.1 Where the site is in the Rural Zone— Not applicable.
O11 Dam location and construction does not a) the land has a slope of less than 25% (1:4); and
impact upon neighbouring properties in b) the earthworks including cut and fill batters and The subject site does not comprise environment and/or cultural
terms of— retaining walls are setback a minimum of 50m from heritage values.
a) hydrology; the property boundary; and
b) alteration of existing overland flowpaths c) the size of the lot is greater than 5 Hectares;
and patterns;
c) landslide or failure of dam wall; and AND
d) effluent disposal areas.
S11.2 Where the site is in the Rural Settlement
Zone or the Rural Zone where the lot is less than 5
Hectares—
a) the land has a slope of less than 1:6; and
b) the earthworks including cut and fill batters and
retaining walls are setback a minimum of 20m from
the property boundary; and
c) involving less than 500m3 of material;
See the original
The page text is free to read. Viewing or downloading an original file needs an account.