Construction Vehicle Access
10.    Park Road has to be used to enter this area, and it is subject to a 9 tonne load limit. The
       Shire Engineer has approved the use of Upper Bayview road for the delivery of
       specialised items of equipment that are essential to the work to proceed and which
       exceed 9 tonnes load limit. This envisages an excavator and concrete pump truck but
       does not include the routine delivery of construction materials including concrete, nor
       does it include spoil removal. The Applicant will need to apply for approval for each
       specialised item.
Carparking
11.    A minimum of three (3) covered carpark spaces shall be provided on site.
12.    The carparking area shall be designed to comply with the provisions of AS 2890.1-1993
       for user class 1 with a minimum head clearance (headroom) at any point of 2.2m.
13.    All carparking shall be kept, maintained and line-marked in a condition fit for use.
Roadworks Contributions
14.    A roadworks contribution of $2,672 towards the Coastal Major Road Network shall be
       paid to the Council prior to obtaining a Development Permit for Operational W orks. This
       amount will be subject to variations in the Price Index, All Groups Brisbane from March
       2003 until the date of payment.
Stormwater Drainage
15.    Roof and surface water is to be collected on site and is to be discharged into the existing
       inter allotment discharge pipe located adjacent to southern property boundary.
16.    All site stormwater drainage shall be by means of a gravity system.
Sewer Mains
17.    The site shall be connected to Council’s existing sewerage reticulation systems and be
       constructed in accordance with Council’s standards and requirements at no cost to
       Council.
Town Water Supply
18.    The site shall be connected to Council’s existing town water supply and be constructed in
       accordance with Council’s standards and requirements at no cost to Council.
Service Easements
19.    A minimum setback of 2.1 metres shall be maintained from the private sewer in
       accordance with the requirements of the Building Units and Group Titles Act, 1980.
Earthworks
20.    A Registered Professional Engineer Queensland shall certify all retaining wall and deep
       footing designs and certify that he or she has supervised all engineering works an that all
       works have been completed in accordance with the relevant Australian Standards and
       the Morrison Geotechnic report dated 7th April 2003 and best engineering practice.
21.    The site will require the design of a soil retaining system by a Structural Engineer.
       Clearance shall be obtained from Council’s Manager of Building as part of the process of
       obtaining a Development Permit for Building works.




PD-DA-FM383/5-09/08/2010                                                            Page 3 of 7

Used in these records

About this file

File size
181 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

ECM_16004986_v3_Change Existing Approval - 132003 220660 4 - 23182 DA 1 1-7 Bayview Rd Noosa Heads - Extension to Cu.pdf · 181 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.