53 Doonella St Minor Change Full Set
GENERAL NOTES:
BUILDING WORK MUST NOT COMMENCE WITHOUT CERTIFICATION FROM A RPEQ REGISTERED ENGINEER BY SMOKE ALARMS TO COMPLY WITH NEW QUEENSLAND LEGISLATION.
WAY OF A FORM 15 DESIGN COMPLIANCE CHECK OF ANY STRUCTURAL DETAIL OR SPECIFICATION PROVIDED IN
THESE PLANS. TOILET DOORS TO COMPLY WITH BCA PART 3.8.3.3
CONTRACTORS TO VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING CONSTRUCTION WET AREAS TO COMPLY WITH BCA PART 3.8.1
USE FIGURED DIMENSIONS ONLY. DO NOT SCALE FROM DRAWINGS. ALL EXPOSED TIMBER ENDS AND EDGES TO BE FINISHED WITH A 5mm ARRIS -UNLESS NOTED OTHERWISE
REPORT ANY DISCREPANCIES ON DRAWINGS TO THE PROJECT MANAGER BEFORE COMMENCING OR ROOF WATER REMOVAL AND DISCHARGE TO LOCAL AUTHORITY APPROVAL
CONTINUING CONSTRUCTION
REFER TO STRUCTURAL ENGINEER'S DRAWINGS FOR DETAILS OF CONCRETE FOOTINGS, SLABS AND
ALL WORKMANSHIP IS TO COMPLY IN ALL RESPECTS WITH NCC 2022 VOLUME 2 BUILDING CODE OF AUSTRALIA, RETAINING WALLS, AND STEEL DESIGN.
AND RELEVANT AUSTRALIAN STANDARDS. BUILDING CONTRACTORS AND CARPENTERS ARE TO HAVE A COPY
OF AS1684.2 RE SIDENTIA L TIMBER FRAMED CONSTRUCTIO N - ON SITE DURING CONSTRUCTION AT ALL TIMES REFER TO ENERGY EFFICIENCY REPORT FOR INSULATION REQUIREMENTS AND OTHER SPECIFICATIONS TO BE
FOR REFERENCE PURPOSES. INCLUDED.
TERMITE PROTECTION IN ACCORDANCE WITH AS3660.1 ALL PRODUCTS TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATION
STAIRS AND BALUSTRADES TO COMPLY WITH ABCB HOUSING PROVISIONS PART 11.2 AND 11.3 ANY DAMAGE CAUSED BY THE CONTRACTOR SHALL BE MADE GOOD AT THEIR OWN COST
WINDOWS OF FIRST FLOOR BEDROOMS SHALL BE PROTECTED TO PREVENT FALLS IN ACCORDANCE WITH CONTRACTOR MAY ONLY USE PRODUCTS SPECIFIED. ANY SUBSTITUTION OF PRODUCTS MAY ONLY TAKE
ABCB HOUSING PROVISIONS PART 11.3.7 PLACE BY AGREEMENT WITH THE PROJECT MANGER OR OWNER
INTERNAL LININGS TO BE PLASTERBOARD TO GENERAL AREAS AND MOISTURE RESISTANT PLASTERBOARD OR
VILLABOARD TO WET AREAS - UNLESS NOTED OTHERWISE
1000 2000 3000 4000 5000 JOB NO:
PROJECT:
2103
53 DOONELLA STREET TEWANTIN QLD
SCHEDULES AND NOTES BA5308
ph 0407 915 220 SCALE 1:100 @ A3
NOTE: THIS SHEET SHOULD BE ELECTRONICALLY PRINTED FROM FILE ON A3
CLIENTS: ASHBURTON PASTORAL COMPANY ATF BLOODWOOD TRUST Plan reference: BUILDING APPLICATION - ISSUE A
email [email protected] PAPER @ 100%. PRINTER OPTIONS SHOULD BE SET TO "NORMAL SIZE" LOCATION: TEWANTIN
web arcoeco.com.au PRINTING, NOT "FIT TO PAGE". IF A SECOND THIN BOARDER APPEARS
AROUND THE PAGE THE DRAWING WILL NOT BE TO SCALE RPD:
All rights reserved. This work is copyright and cannot reproduced or copied in any form or by any means (graphic,
electronic, mechanical including photocopying) without the written consent of Arco Eco