Appendix F - Bushfire Hazard Assessment & Management Plan
Plans and drawings
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawnBushfire Hazard Assessment & Management Plan v1 NCES REF: J000669 Lot 2 on RP131369 – 108 Black Mountain Range Road, Black Mountain 3.3 Quantitative Modelling Quantitative modelling of the potential bushfire conditions that may be experienced within the identified High Potential Bushfire Intensity Area associated with the VHC 9.1 open Eucalypt forest to the west of the site has been undertaken to assist in determining the suitability of the development and any asset setback requirements. The models used comprise industry standard bushfire equations which have been built into the FPAA endorsed FLAMESOL computer model. FLAMESOL allows numerous input variables to be adjusted including fuel loads, fire danger index, site slope and distance to vegetation. FLAMESOL uses the following algorithms: · Rate of Spread – McArthur (1973) and Nobel et al. (1980) · Flame Length – NSW Rural Fire Service (2001) and Nobel et al. (1980) · Elevation of Receiver – Douglas and Tan (2005) · Flame Angle – Douglas and Tan (2005) · Radian Heat Flux – Drysdale (1999), Sullivan et al. (2003) and Douglas and Tan (2005) The FLAMESOL Minimum Distance calculator has been used and comprises an AS 3959:2018 Method 2 (Appendix B) based calculator which will determine standard bushfire behaviour variables as well as the minimum distances required to achieve a range of different radiant heat levels (represented by BAL's). Fuel load inputs have been drawn from Planning for Bushfire Resilient Communities (QFES 2019) based on the calculated potential fuel loads for VHC 9.1 (21t/ha surface and near surface fuels and 24.2t/ha total fuels). 12º effective slope was adopted for the slope underlying the vegetation unit located within the 150m assessment area. A Forest Fire Danger Index (FFDI) of 47 has been adopted for the site consistent with the assignment by QFES (Catalyst 2020) (refer Plate 7). Plate 7 – FFDI (Source: QFES redi Map) The Flamesol output results are shown in Plate 8. © 2021 15
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.