SUPERSEDED Change to an Existing Approval - 010.2001.00210331.005 [As Published] · 132001.210331.5
22441 DA (2001/210331)
9. The requirements of this development approval are to be satisfied, prior to the commencement
of the use of the premises. Council reserves the right to call upon the bond or guaranteed sum
referred to in this approval to effect compliance with conditions.
10. The Development Permit for a material change of use of premises lapses if the use has not
happened by 13 June 2010, unless an application to extend the currency is approved by
Council.
11. The developer must obtain all of the other Development Permits referred to in the Decision
Notice, prior to obtaining a Development Permit for building works.
Land Development
Vehicle Access
12. A vehicular access driveway to serve the site shall be constructed from the Park Road
frontage of the site with a maximum width of 3.0 metres.
The driveway shall be designed and constructed to Council’s design standards and to grades
that prevent vehicles from scraping and/or bottoming. Should any driveways be constructed to
grades that do not comply with AS2890.1-1993 and AS2890.2-1989, Council will require that
the driveway be removed and reconstructed to levels that do comply.
13. All vehicles shall enter and leave the site in a forward direction.
14. All vehicles shall enter the site via a right turn and exit the site via a left turn.
15. Council Officers must approve vegetation trimming within the road reserve required to improve
the sight distance in conjunction with the Development Permit for Operational Works (access).
However, no trees are to be removed from the road reserve.
Carparking
16. Carparking and Turn Table shall be provided within the site as shown on drawing number SK-
A-03.01 dated 08 May 2008 revision P10 submitted by Cecilia Brown Design and Associate,
except as modified herein.
17. A minimum of 2 covered carpark spaces shall be provided on site.
18. The carparking area shall be designed to comply with the provisions of AS 2890.1-1993 for
user class 1 except the minimum head clearance (headroom) at any point shall be 2.3m.
Stormwater Drainage
19. All stormwater drainage shall be collected on site and discharged to Council’s existing
drainage structures on the eastern side of Park Road. The design shall incorporate some
means of reducing the head of the discharge prior to entry to Council’s system. In this regard,
plans shall be prepared by a Registered Professional Civil Engineer and submitted to Council
prior to obtaining a Development Permit for Operational Works.
20. The stormwater drainage system shall be designed in accordance with plan titled, ‘Stormwater
& Sewerage Details, Robertson Residence’ by whaleycg consulting group.
21. The site shall be connected to Council’s existing sewerage reticulation systems in Park Road
and be constructed in accordance with Council’s standards and requirements at no cost to
Council.
To ensure Council’s sewer main is accessible for maintenance purposes and is protected from
risk of damage, no structures requiring a building permit (eg. buildings, retaining walls
exceeding 1m in height, raised terraces, etc) shall be constructed within the ‘zone of influence’
or within 1.5m of the centreline of the sewer main, whichever is the greater. As such the
applicant shall indicate the location of the sewer main and setback distance on the Building
plans to ensure compliance.
Page 4 of 11
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
SUPERSEDED Change to an Existing Approval - 010.2001.00210331.005 [As Published]Related documentApplication case desk ↗
About this file
- File size
- 69 KB (small file)
- File type
No other editions are linked here.