Council archive · source document
RFI - proposal plans · MCU25/0057
Plans and drawings: the text below has words only, no drawings.
Very large file (12.3 MB): may take a few minutes to open.
♻ play your part - print on recycled paper
5m 4 3 2 1
COLORBOND® steel Custom Orb oof sheeting to be fixed in
accordance with manufacturers specifications.
Timber framed walls to be constructed in accordance with structural
engineers design and detail. Walls to have Hebel wall panels finished
with acrylic render system with fine sand finish and painted.
STRATCO 200mm Edge gutters in COLORBOND® steel to be
fixed in accordance with manufacturers specifications. 180 x
Powdercoated aluminium framed screen with 25 x 25mm Hinoki 30mm h3 treated primed timber fascia. Gutters to have 10mm
Knotwood aluminium battens to each side of frame to form privacy spacers to fascia to provide overflow point.
screen.
8,605
Ceiling
Fabriacted Powdercoated aluminium 50 x 10mm bars
@ 100mm cts. with 70 x 10mm top rail to provide
2,700
balustrade in accordance with ABCB Housing Timber framed walls to be constructed in accordance
Provisions Standard 2022 : 11.3. Balustrade to be a with structural engineers design and detail. Walls to
min. 1000mm high above finished floor level. have Hebel wall panels finished with acrylic render
5,905 5,905 5,905 system with fine sand finish and painted.
First floor
4,450
3,205
4,050
3,650
2,700
Ground floor
1,650 Concrete block wall to be in
Knotwood Hinoki aluminium battens to form fence/gate. Battens to be accordance with structural
100 x 25mm sections (125mm max. spacing typical) to have engineers design and detail.
concealed fixings in accordance with manufacturers specifications. Provide Crackenback stone facing
Panels to be self-supported with 12mm threaded rods & 20mm by Eco outdoor.
Powdercoated aluminium spacer set down 300mm from top of
battens. Modinex Beachclad Channel (Mist) bandsawn cladding installed in
accordance with manufacturers specifications.
Double CHS steel column (hdg) to be in accordance with structural
engineers design and detail.
Southern Elevation
S 1:100
/Users/benthornton/Documents/Cadfiles/2503 - Palazzesi - 9 George/Archicad/
09072025/2503.pln
sbt designs pty ltd t/a
Skale Building Design project Duplex lot no. 8 DA06 Development application issue 9/7/2025
project number
Mobile: 0412 025 657
for Ross Palazzesi plan no. RP72243 DA05 Development application issue 30/6/2025
2503
skale skale.com.au
DA04 Development application issue 25/6/2025
9 George Street drawn BT
DA03 Development application issue 24/6/2025
drawing number
[email protected]
building design A.C.N. 123 976 296 QBCC: 1143 609 at Noosaville scale (A3) 1:100 Rev Details Date 10 DA06 © Skale Building Design
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
RFI - proposal plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 12.3 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.