                                                                                                                                                                                                                               5m         4          3         2          1




                                                                                                                                                                                                Tiger Neo N-type JKM440N-54HL4R - 440 Watt PV panels to
                                                                                                                                                                                                be installed on 316 s/s clamps. System to be installed in
                                                                                                                                                                                                accordance with specialist solar electricians' design and detail.
                    COLORBOND® steel Custom Orb oof sheeting to be fixed in                                                                                                                     System to be connected to battery storage/grid connection.
                    accordance with manufacturers specifications.
                                                                                                                                                                                                STRATCO 200mm Edge gutters in COLORBOND® steel to be
                                                                                                                                                                                                fixed in accordance with manufacturers specifications. 180 x
                                                                           2,013                           9,498                                                                                30mm h3 treated primed timber fascia. Gutters to have 10mm
                                                                                                                                                                                5.0°            spacers to fascia to provide overflow point.

                               8,605
                               Ceiling

                    Timber framed walls to be constructed in accordance with                                                                                                                    Knotwood Hinoki aluminium pergola roof battens.
                    structural engineers design and detail. Walls to have Hebel                                                                                                                 Battens to be 150 x 50mm sections (300mm typical.
                    wall panels finished with acrylic render system with fine                                                                                                                   spacing) to have concealed fixings in accordance with
                    sand finish and painted.                           1,513                                                                                                                    manufacturers specifications.
                               5,905                                       5,905                             5,905
                               First floor
                                                                                                                                                                                                Double CHS steel column (hdg) to be in accordance
                                                                                                                                                                                                with structural engineers design and detail.
                                                                   4,450                                                                                                                4,450




                               2,700                                                                        2,700
                               Ground floor
                                                                   1,650                                                                                                                1,650




                                             Section B
 B                                                         1:100
                                                                                                                                                                                                          /Users/benthornton/Documents/Cadfiles/2503 - Palazzesi - 9 George/Archicad/
                                                                                                                                                                                                                                                                   09072025/2503.pln
                       sbt designs pty ltd t/a
                       Skale Building Design                                   project   Duplex                      lot no.                 8   DA06   Development application issue                         9/7/2025
                                                                                                                                                                                                                         project number
                       Mobile: 0412 025 657
                                                                               for       Ross Palazzesi              plan no.          RP72243   DA05   Development application issue                        30/6/2025
                                                                                                                                                                                                                         2503
skale skale.com.au
                                                                                                                                                 DA04   Development application issue                        25/6/2025
                                                                                         9 George Street             drawn                 BT
                                                                                                                                                 DA03   Development application issue                        24/6/2025
                                                                                                                                                                                                                         drawing number
                       [email protected]
  building design      A.C.N. 123 976 296 QBCC: 1143 609                       at        Noosaville                  scale      (A3)     1:100   Rev    Details                                                  Date    15          DA06                    © Skale Building Design

Used in these records

About this file

File size
12.3 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

RFI - proposal plans.pdf · 12.3 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.