Effluent Disposal Report

of 11

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

                                                                            QBCC Licence No.1018403

            THE ONLY NAME IN SOILS                 UNIT 3/53 GATEWAY DR, NOOSAVILLE , 4566

                                   Ph.0754740900/ Fax.0754740901/ email: [email protected]

JOB NUMBER    19/0161      EFFLUENT DISPOSAL REPORT
CLIENT        JUSTINE OXLEY.
SITE LOCATION PROPOSED RESIDENCE,
              411 BLACK PINCH ROAD, COOTHARABA.
REPORT DATE   08/03/19



1.   INTRODUCTION

     The purpose of this report is to evaluate and define a suitable on-site sewerage treatment and
     disposal system for household effluents in accordance with Australian Standard 1547 - 2000
     “On-site domestic-wastewater management”. The Qld Plumbing & Wastewater Code has been
     used for reference purposes during the compiling of this report.

     This report relates exclusively to the proposed residence at 411 Black Pinch Rd, Cootharaba.
     This document has been prepared for the express purpose stated above. This document does not
     cover any other elements related to construction on the site.


2.   SITE DESCRIPTION AND WEATHER CONDITIONS

     The site is an acreage allotment, which fronts an unsealed road. The proposed residence site was
     marked on site.
     The slope configuration in relation to surface drainage is linear planar.
     The soil surface condition was moist at the time of testing. There was no evidence of cracking of
     the surface during the investigation.
     The site has no visible rock outcrops on the surface of the allotment.
     The proposed effluent disposal area is exposed to sun and wind.
     The proposed effluent disposal area is grassed. The proposed effluent disposal area falls at a
     slope of approximately 18% towards the north. Surface water drainage from adjoining allotments
     will not traverse this site. Surface water from the tested area will drain towards the north.
     The weather conditions prior to testing were periods of moist conditions.
     The site has Intermittent watercourses approximately 70m downhill of the proposed effluent
     disposal area.

3.   SOIL PROFILE

     The borelogs carried out at the site, refer attached Site Plan for localities, indicate that the soil
     profile typically consists of a moist, pale brown, low plasticity SANDY CLAY. Underlying this
     is a moist, pale brown, high plasticity SANDY CLAY.
     Groundwater was not encountered during the field investigation.
     Rock was not encountered during the field investigation.

     RESERVE AREA

     A 100% reserve effluent disposal area can be obtained on this allotment.
Log in to download the original file

Effluent Disposal Report.pdf · 463 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

Full text of the other 10 pages

Page 2

     Whilst every effort has been made to ensure that the borelogs carried out at the subject allotment
     are indicative of the soil profile over the site any discrepancy between the profile detailed in the
     borelogs and that observed during construction shall be referred to Global Testing for immediate
     attention.

4.   INVESTIGATION DETAILS

     The investigation carried out at the site included machine augered boreholes up to 2000mm
     depth and a series of three permeability test pits located as shown on the attached site report. All
     testing carried out was in accordance with Australian Standard 1547 - 2000 “On-site domestic-
     wastewater management”.


5.   TEST RESULTS AND CONCLUSIONS (TABLE A1)
      Test No.  Soil           Slope Setback   Recommended                                  Beavers
                Permeability   (m/m) Distance Design Irrigation                             Gardner
                (based on test       (m)      Rate (mm/week)                                Setback
                results)Ksat                   As per AS/NZS                                Distance
                                                 1547-2000
      PT 1           0.04
      PT 2                   0.10
      PT 3                   0.07
      Average                0.07           .18           30*                20                 3m

     *Minimum setback distance from a watercourse (when a Secondary Quality ASTP or Sand
      Filter is recommended) required by Noosa Council Policy.

     Determination of Soil Category (Table 4.1.1 of AS/NZS 1547:2000)
       Soil Category         Soil Texture         Structure          Indicative          Indicative
             BH4                                                    Permeability       Drainage class
                                                                    (ksat)(m/day)
             4               Clay Loams            Weakly            0.12 to 0.5         Imperfectly
        (00-200mm)                                Structured                              Drained
             6               Medium to            Moderately            < 0.06           Very Poorly
       (200-2000mm)          Heavy Clays          Structured                              Drained

     The Design Irrigation Rate of 20 mm/week was adopted from the above results in Table A1.

     Noosa Council`s policy suggests that the use of a primary treated effluent disposal system
     will be satisfactory provided ;
         # Sufficient permeable surface soil overlying rock is present over the disposal area, not
          less than 1.2metres depth.
        # A suitable soil category material (as per AS1547-2000) is encountered.
        # A Minimum set-back distance of 50m is obtained.
        # Permeability rates are within the required parameters.
        # The site is located outside a catchment area.
     Not all the above requirements have been met, therefore it is concluded that the use of a
     primary treated effluent disposal system is not acceptable.



                                        Report 19/0161 edrpage2

Page 3

6.      RECOMMENDATIONS

            The Design Irrigation Rate of 20mm/week be adopted.
            The site be provided with an “Aerated wastewater-treatment system” capable of
             producing secondary effluent (with a thermotolerant coliform level equal to or less
             than 10), or an equivalent system (e.g Eco-Safe Sand Filter), to council’s approval in
             lieu of a septic tank.
            The disposal system be by, # A Fixed Surface Spray Irrigation System, as per AS/NZS
             1547:2000. Purple line is to be used from the ASTP to the irrigation area.
            An in-line Filter is to be installed between the Treatment Plant and the Irrigation System.
             Regular maintenance of the Filter shall be undertaken, according to the manufacturer’s
             requirements.
            The area shall be surrounded by a 150mm high earth mound or similar.
            The spray irrigation system shall distribute the effluent evenly (via a K-Rain Valve)
             within the designated area through coarse spray heads suitable for use with effluent, and
             shall not produce aerosols. All ‘plumes’ shall be evenly distributed and fixed in place
             with a height of approx. 0.3m and have a throw of no greater than 2.0m. It is estimated
             that approximately 28 plumes would be required.
            Non-return valves and flush-out valves should be installed on irrigation lines.
            The disposal area should be mulched to a depth of 100mm.
            Evergreen plants (approx. 30 plants) shall be planted to maximize evapo-transpiration.
            The disposal area required is 242m2.
             A daily flow rate of 690 litres/day (6 persons @ 115 litres per person/per day) has been
             adopted with a Design Irrigation Rate of 20mm/week, using Standard Water-reduction
             fixtures (Standard water-reduction fixtures include a dual flush 6/3 litre (minimum)
             water closet, shower-flow restrictors, aerator faucets, and a water-conserving washing
             machine). These fixtures must be installed. This flow rate will accommodate the
             proposed 4 bedroom residence using standard water-reduction fixtures only. A 100%
             reserve area (as per site plan) is to be kept free of buildings and traffic.
            The disposal area should be located in the vicinity of PT 1, PT 2 and PT 3 as per attached
             site plan.
            All set-back distances as required by the local authority shall be met;
             At least two signs stating “Recycled water- Do not drink” are to be erected on boundaries

        . Stormwater run-off including roofwater from buildings shall be diverted around and away
            from the disposal area. Imported fill may be required should there be insufficient soil available
            for the design of the disposal system.
            Please note: Personal Hygiene Products, Bleaches and detergents high in phosphorous will
            damage the capabilities of the Treatment System’s performance. Information should be
            sought by the Treatment System’s manufacturer for a guide of suitable products acceptable
            for the system.(some examples attached to this report).
Certification
The local authority may request that an inspection and certification is undertaken on the installation of the
system when nearing completion. The installer must contact Noosa Council prior to ‘burying’ the system,
if certification is required.

Yours Sincerely,




Michael S. Pinkney (Laboratory Manager) Report 19/0161 EDR-page3

Page 4

               THE ONLY NAME IN SOILS


SOIL PROFILE REPORT
CLIENT:               Justine Oxley                           AUTHORIZED                Justine Oxley
                                                              BY:
PROJECT:              411 Black Pinch Rd,                     DATE TESTED:              05/03/19
                      Cootharaba.                             JOB NO:                   19/0161

                        Drilling Method: Jacro 105 100mm                                           Borehole
                                                                                                    No: 3
                    Description                                                    PENET.         Comments
    Depth                                                                     (blows per 100mm)
    (mm)
                                                                              1     2    3    4
       0            SANDY CLAY (CL)- Low plasticity,
                    pale brown, fine to coarse sand, moist,
     100            stiff.

     200            SANDY CLAY (CH)- High plasticity,
     300            pale brown, fine to coarse sand, moist,
                    stiff.
      400
      500
      600
      700
      800
      900
     1000
     1100
     1200
     1300
     1400
     1500           SANDY CLAY (CL)- Low plasticity,
                    pale brown, fine to coarse sand, moist,
                    stiff.
     1600
     1700
     1800
     1900
     2000           Hole Terminated.
     2100
     2200
     2300
     2400
     2500
Borelogging in accordance with AS1726-1993 Site Investigation Code
                                                         19/0161-edr Page 4

Page 5

             THE ONLY NAME IN SOILS

SOIL PROFILE REPORT
CLIENT:               Justine Oxley                           AUTHORIZED                Justine Oxley
                                                              BY:
PROJECT:              411 Black Pinch Rd,                     DATE TESTED:              05/03/19
                      Cootharaba.                             JOB NO:                   19/0161

                        Drilling Method: Jacro 105 100mm                                           Borehole
                                                                                                    No: 4
                    Description                                                    PENET.         Comments
    Depth                                                                     (blows per 100mm)
    (mm)
                                                                              1     2    3    4
       0            SANDY CLAY (CL)- Low plasticity,
                    pale brown, fine to coarse sand, moist,
     100            stiff.

     200            SANDY CLAY (CH)- High plasticity,
     300            pale brown, fine to coarse sand, moist,
                    stiff.
      400
      500
      600
      700
      800
      900
     1000
     1100
     1200
     1300
     1400
     1500
     1600
     1700
     1800
     1900
     2000           Hole Terminated.
     2100
     2200
     2300
     2400
     2500

Borelogging in accordance with AS1726-1993 Site Investigation Code
                                                         19/0161-edr Page 5

Page 6

            THE ONLY NAME IN SOILS


SOIL PROFILE REPORT
CLIENT:               Justine Oxley                            AUTHORIZED               Justine Oxley
                                                               BY:
PROJECT:              411 Black Pinch Rd,                      DATE TESTED:             05/03/19
                      Cootharaba.                              JOB NO:                  19/0161


                        Drilling Method: Jacro 105 100mm                                           Borehole
                                                                                                    No: 5
                    Description                                                    PENET.         Comments
    Depth                                                                     (blows per 100mm)
    (mm)
                                                                              1     2    3    4
       0            SANDY CLAY (CL)- Low plasticity,
                    pale brown, fine to coarse sand, moist,
     100            stiff.

     200            SANDY CLAY (CH)- High plasticity,
     300            pale brown, fine to coarse sand, moist,
                    stiff.
      400
      500
      600
      700
      800
      900
     1000
     1100
     1200
     1300
     1400
     1500
     1600
     1700
     1800
     1900
     2000           Hole Terminated.
     2100
     2200
     2300
     2400
     2500
Borelogging in accordance with AS1726-1993 Site Investigation Code

                                                         19/0161-edr Page 6

Page 7

* DO NOT Allow newspapers, disposable or sanitary napkins, rubber products,
         nappy liners, cotton buds etc. to enter the system.



* DO NOT Use an in-sink garbage grinder. These are not recommended by most
         councils as they can add extra loading equivalent to about 2 persons.



* DO NOT Use strong caustics, acids, alkalis or chemical detergents. These can
         damage the system and cause bad odours.




* DO NOT Use disinfectants or other bactericides.



* DO NOT Put grease/fats or food scraps down the kitchen sink i.e plates should be
         scraped resonably clean prior to washing up.


* NEVER       Dispose of used cooking oil or similar material down the sink.




                                     19/0161-edr Page 7

Page 8

 

19/0161-edr Page 7

Page 9

                     Surface Irrigation system (sprays)
To be mulched and planted out
                                      3m                                     0.3m plumes
    Ground Level




                                                                             Heavy droplet
                                                                             (Plumes e.g 10mm
                                                                               feeder lines)
                                 25-32mm diameter poly lines laid beneath surface.




                     150mm high mound surround




                                            Slope up to 30%



                                 Typical Plan Layout of Manifold and Laterals for an
                                            Irrigation Area of 242m2

25-32mm dia poly lines
     K-Rain Valve                               1.5m
To
ASTP
or Eco-Safe                                     3m
Sand Filter                      1m
                                       3m
                                                       To be mulched and planted out
                         12.1m




                                                               20m
                                 Plumes                                     Land Slope

                                            Flush-out valves

Page 10

Page 11

                   The only name in soils


                           Test Locality Plan
                                                            LEGEND
                                                               BH - Borehole Location


     N
                                                               PN - Dynamic Cone Penetrometer Location
                                                               PT - Percolation Test




          20m



                 BH5                      12.1m
                        18% Slope
                 PT3                       Proposed Residence
           BH4                             (Marked on site with a Tyre
                   10m BH2
           PT2         PN2                 on Steel Posts)
             BH3
      65m
             PT115m      BH1 11-14% Slope
      approx             PN1
                approx




                              ASTP or Eco-Safe Sand Filter (To be installed in a suitable location
                                          by installing plumber)
    Proposed Fixed Surface Irrigation Area-242m2 (i.e 20m wide across contour x 12.1m deep)
    (To be planted out, mulched, bordered and installed, and placed a minimum of 10m from
    the proposed residence. K-Rain Valve to be used- see attached diagram)




                                                                                                                 Not to Scale
Note: Any dimensions, contours, slope directions and magnitudes shown on the plan shall not be used for any building
construction or costing calculations. The purpose of the plan is to show the approximate location of the field tests only. All
dimensions in metres UNO .



Justine Oxley                                                                                                            Job No. 19/0161
411 Black Pinch Rd,                                                                                                Date Tested :05/03/19
Cootharaba.                                                                                                     Authorised:-Justine Oxley