Original source · versioned page text
Subdivision Plans
- Z:\14_Nigel's Backup\STUFF\107\LOT 107 WKG
DWG'S Stage 1 Rev D 201016.pln
NOOSA COUNCIL
APPROVED PLAN REVISION A
MCU20/0074 7 DEC 2020
ABODE SOLUTIONS
STAGE 1
Design & Drafting
0400 799 146
Screening plants to be planted along boundaries
Mix of 20L Fraser Island Apples and Lilly Pillys
1 tree every 1m
24.996 3.0 132°48'00" (50.322) 22.326
Grass
cells
dp dp
Grass
Batter
UNIT 1
TEWANTIN ROAD
OLIVINE LANE
EASEMENT
42°48'10"
Existing 4,500
20.117
dp
Up
Residence
dp
Up
dp
1,500
UNIT 2
Grass
Batter Concrete driveway
3,000
to Council
dp dp requirements
24.996 3.0 132°48'00" (50.322) 22.326
114.0 115.0 116.0 117.0 118.0 119.0 120.0
Screening plants to be planted along boundaries
N
LOT 107
Mix of 20L Fraser Island Apples and Lilly Pillys
Area = 1,012.33m² 1 tree every 1m
1 Site Layout Plan
1:200 The designs and drawings shown on these plans
are copyrighted and remain the property of
Abode Solutions, Unauthorized copy/distribution
of these plans is prohibited.
Landscaping = 427m2 (42%)
Client Name
5 x 45L Queensland Maple Trees (Flindersia brayleyana) Mr M Tarrant
Project Name
Not including 2m of road reserve to Proposed New Residence
be dedicated and grassed... Lot 107, Tewantin Road,,
Cooroy, Qld, 4563
Drawing Title:
SITE LAYOUT PLAN
Scale:
As Shown @ A3 Size Date: 18.10.2020
Status: Checked By: NPH
CD
Project No: Drawing No.:
CDP107 SD03
Document Set ID: 21315566 Plot Date: 20/10/2020
Version: 1, Version Date: 10/12/2020
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original (Subdivision Plans.pdf)
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.
Full text of the other 10 pages
Page 2
-
NOOSA COUNCIL
APPROVED PLAN
MCU20/0074 7 DEC 2020
Document Set ID: 21315566
Version: 1, Version Date: 10/12/2020
Page 3
- Z:\14_Nigel's Backup\STUFF\107\LOT 107 WKG
STAGE 1
DWG'S Stage 1 Rev D 201016.pln
NOOSA COUNCIL
APPROVED PLAN REVISION A
MCU20/0074 7 DEC 2020 10,400
132°48'00"
24.996
2,500
storage location
ABODE SOLUTIONS
Refuse bins
Bin
2,747
OMP
3,197
Design & Drafting
Garden Bed
Bin
Grass cells 0400 799 146
2,000
5,000
Clothesline
Guest
Parking Gate Up
ELEC
dp A/C HWS dp
42°48'10"
20.117
UNIT 1
10,400
Face of Garage
OLIVINE LANE
EASEMENT
Driveway and crossover as per
Civil Engineer's drawings
dp
Garden Bed
Up
Proposed New
dp
Residence
6,000
Concrete driveway to
Max.
Council requirements Up
dp
Driveway Paths & Courtyards
A: 154.67 m2
S2 S2
9,900
Face of Garage
UNIT 2
6,450
OMP
The designs and drawings shown on these plans
are copyrighted and remain the property of
Abode Solutions, Unauthorized copy/distribution
2,000 dp A/C HWS dp
of these plans is prohibited.
Road Reserve ELEC Up
Garden Bed Gate Client Name
2,450
Clothesline Mr M Tarrant
2,000
OMP
Bin Bin Project Name
Refuse bins Proposed New Residence
132°48'00"
storage location
Lot 107, Tewantin Road,,
Cooroy, Qld, 4563
24.996
114.0 115.0 116.0 117.0
N Drawing Title:
SITE PLAN
LOT 107
Site Plan Scale:
1 1:100 Area = 1,012.33m² As Shown @ A3 Size
Status:
Date: 18.10.2020
Checked By: NPH
CD
Total Floor Area = 411.72m² Project No: Drawing No.:
CDP107 SD04
Document Set ID: 21315566 Plot Date: 20/10/2020
Version: 1, Version Date: 10/12/2020
Page 4
- Z:\14_Nigel's Backup\STUFF\107\LOT 107 WKG
DWG'S Stage 1 Rev D 201016.pln
NOOSA COUNCIL
APPROVED PLAN REVISION A
MCU20/0074 7 DEC 2020 E-02
16,150
Floor Areas 3,000 13,150
Ground Floor 93.17m2 70 6,870 70
Upper Living 94.27m2 70
Terrace 18.42m2 70 620 1,500 70 ABODE SOLUTIONS
Total 205.86m2 Design & Drafting
70 6,180 70 2,190 70
0400 799 146
Perimeter (Clad) 42.595m 70
70 5,700 70 1,600 1,000 70
Perimeter (Block) 42.200m
140 2,860 1,800 70 6,640 70 4,380 190
190
dp 21.15 sgd 09.09 sw (obs) 21.21 sgd dp
70
140
190
190
1,900
Bench
BATH 720
09.21 sw
2,880
70
Broom
910
21.48 panel lift
900
820
GARAGE
UNIT 1 6,140
6,000
1500
70
5,860
RL - 115.50
Concrete
70
1,000
820 Storage
RUMPUS
6,950
Under
Carpet
70
W
1,860
LDRY
4,000
09.21 sw
1,800
70
70
820
Up
PORCH PORCH
140
dp
1,000
1,000
1,000
Up 820 ENTRY RL - 116.70 820
14,470
E-01
E-03
190
190
190
dp
2,190
190
190
1,000
1,000
1,000
Up 820 ENTRY RL - 116.70 820
dp
Up
70
820
70
140
09.21 sw
1,860
4,000
S1 LDRY S1
W
70
1,000
Storage RUMPUS
6,950
820
21.48 panel lift
Under Carpet
UNIT 2
6,140
6,000
70
GARAGE
5,860
1500
70
RL - 115.50
Broom
910
Concrete
900
820
09.21 sw
70
2,880
BATH 720
Bench
1,900
The designs and drawings shown on these plans
are copyrighted and remain the property of
Abode Solutions, Unauthorized copy/distribution
of these plans is prohibited.
21.15 sgd 09.09 sw (obs) 21.21 sgd
140
70
190
190
190
dp dp
Client Name
140 2,860 1,800 70 6,640 70 4,380 190 Mr M Tarrant
70 Project Name
70 5,700 70 1,600 1,000 70
Floor Areas
Ground Floor
Upper Living
93.17m2
94.27m2
70 6,180 70
70 620
2,190
70
1,500
70
70
N Proposed New Residence
Lot 107, Tewantin Road,,
Cooroy, Qld, 4563
Terrace 18.42m2 70 6,870 70
Total 205.86m2 Drawing Title:
3,000 13,150
Perimeter (Clad) 42.595m
Perimeter (Block) 42.200m
16,150 GROUND FLOOR PLAN
1 Ground Floor Plan Scale:
1:100 E-04 As Shown @ A3 Size Date: 18.10.2020
Status: Checked By: NPH
CD
Project No: Drawing No.:
CDP107 SD05
Document Set ID: 21315566 Plot Date: 19/10/2020
Version: 1, Version Date: 10/12/2020
Page 5
- Z:\14_Nigel's Backup\STUFF\107\LOT 107 WKG
DWG'S Stage 1 Rev D 201016.pln
NOOSA COUNCIL
APPROVED PLAN REVISION A
MCU20/0074 7 DEC 2020 16,030
3,000 13,030
Floor Areas 70 530 70 3,000 70
Ground Floor 93.17m2
140 2,860 70 4,770 70 3,600 70 2,400 70 1,910 70
Upper Living 94.27m2
70
Terrace 18.42m2 70 8,440 70 1,000 760 70 2,480 70 ABODE SOLUTIONS
Total 205.86m2 70 Design & Drafting
Perimeter (Clad) 42.595m 70 7,370 70 1,000 1,000 70 0400 799 146
Perimeter (Block) 42.200m 70 4,300 70 5,140 70 3,310 70
dp 12.06 lvr 09.06 sw dp
12.06 lvr 12.21 sw 12.21 sw (obs)
(obs)
900
70
70 1,930 70
70
70
70
70 2,030 70
140
12.06 lvr
900
Robe
ENS
2,730
3,000
BED 2 BATH
3,000
Carpet
LIVING
720
Timber
900
1,000
70
21.36 stacking
1,500
900
70 TERRACE
UNIT 1 6,140
720
WIR
5,860
820
800
Linen
Timber decking
720
70
70
1,000
7,070
Down
820
90
90
RL - 119.40
12.06 lvr
820
2,930
70
4,000
12.12 fxd
DINING MASTER SUITE
12.06 lvr
3,380
3,380
Timber
2,930
Carpet
70
KITCHEN
Timber
12.06 lvr
140
dp
1,000
Pantry
14,470
14,470
2,190
190
dp
190
190
190
190
190
1,000
Pantry
12.06 lvr
dp
KITCHEN
70
2,930
Timber
140
12.06 lvr
12.12 fxd
MASTER SUITE
3,380
3,380
DINING
4,000
Carpet
Timber
S1 S1
12.06 lvr
2,930
70
820
RL - 119.40
90
90
1,000
820
Down
7,070
21.36 stacking
70
800
Linen
UNIT 2 TERRACE
6,140
720
1,500
820
5,860
Timber decking 720 WIR
70
70
1,000
900
70
900
LIVING 720
70
Timber
70
BED 2 BATH
3,000
3,000
2,730
Carpet ENS
2,030
Robe
1,930
The designs and drawings shown on these plans
12.06 lvr
are copyrighted and remain the property of
900
Abode Solutions, Unauthorized copy/distribution
900
of these plans is prohibited.
09.06 sw
dp 12.06 lvr 12.06 lvr 12.21 sw 12.21 sw (obs)
70
70
70
140
70
70
70
dp
(obs)
Client Name
70 4,300 70 5,140 70 3,310 70 Mr M Tarrant
70 Project Name
N
70 7,370 70 1,000 1,000 70
Floor Areas Proposed New Residence
70
Ground Floor 93.17m2 70 8,440 70 1,000 760 70 2,480 70 Lot 107, Tewantin Road,,
Upper Living 94.27m2 Cooroy, Qld, 4563
Terrace 18.42m2 140 2,860 70 4,770 70 3,600 70 2,400 70 1,910 70
Total 205.86m2 70 530 70 3,000 70
Drawing Title:
Perimeter (Clad) 42.595m
3,000 13,030
Perimeter (Block) 42.200m
16,030 UPPER FLOOR PLAN
Scale:
1 Upper Floor Plan As Shown @ A3 Size Date: 18.10.2020
1:100
Status: Checked By: NPH
CD
Project No: Drawing No.:
CDP107 SD06
Document Set ID: 21315566 Plot Date: 19/10/2020
Version: 1, Version Date: 10/12/2020
Page 6
- Z:\14_Nigel's Backup\STUFF\107\LOT 107 WKG
DWG'S Stage 1 Rev D 201016.pln
NOOSA COUNCIL
APPROVED PLAN REVISION A
MCU20/0074 7 DEC 2020
Colorbond metal sheet roof @ 14° pitch
450 Colorbond metal fascia and gutter
Eaves
ABODE SOLUTIONS
Design & Drafting
0400 799 146
Hardies Axon wall cladding
2,700 CL
2,100 JL
Aluminium framed doors and windows
7,230
140 x 140 Painted timber posts
Balustrading as per Spec.
2,400 CL RL - 119.40
Hardies Linea weatherboard cladding
2,100 JL
3,600
Garage and Entry doors as per Spec.
RL - 116.70
RL - 115.50
NGL
View from Boundary
1 Elevation 01
1:100
Colorbond metal sheet roof @ 14° pitch
450
Colorbond metal fascia and gutter Eaves
Hardies Axon wall cladding
2,700 CL
The designs and drawings shown on these plans
2,100 JL
are copyrighted and remain the property of
Front boundary
Rear boundary
Abode Solutions, Unauthorized copy/distribution
of these plans is prohibited.
Client Name
Mr M Tarrant
Project Name
Proposed New Residence
2,400 CL
2,100 JL
Lot 107, Tewantin Road,,
Garage CL
Cooroy, Qld, 4563
3,600
dp
View from Boundary Drawing Title:
NGL
ELEVATIONS 01
FGL dp
Scale:
As Shown @ A3 Size Date: 18.10.2020
2 Elevation 02 Status:
CD Checked By: NPH
1:100 Project No: Drawing No.:
CDP107 SD07
Document Set ID: 21315566 Plot Date: 19/10/2020
Version: 1, Version Date: 10/12/2020
Page 7
- Z:\14_Nigel's Backup\STUFF\107\LOT 107 WKG
DWG'S Stage 1 Rev D 201016.pln
NOOSA COUNCIL
APPROVED PLAN REVISION A
MCU20/0074 7 DEC 2020
Colorbond metal sheet roof @ 14° pitch
450
Colorbond metal fascia and gutter
Eaves ABODE SOLUTIONS
Design & Drafting
0400 799 146
Hardies Axon wall cladding
2,700 CL
2,100 JL
Aluminium framed windows and doors
FGL
dp
NGL
View from Boundary
3 Elevation 03
1:100
450 Colorbond metal sheet roof @ 14° pitch
Eaves
Colorbond metal fascia and gutter
Hardies Linea weatherboard cladding
2,700 CL
2,100 JL
7,230
Front boundary
Rear boundary
The designs and drawings shown on these plans
are copyrighted and remain the property of
Abode Solutions, Unauthorized copy/distribution
of these plans is prohibited.
2,400 CL
2,100 JL
Garage CL
Client Name
Mr M Tarrant
3,600
Project Name
dp FGL
Proposed New Residence
Lot 107, Tewantin Road,,
NGL Cooroy, Qld, 4563
dp
FGL
View from Boundary
Drawing Title:
Elevation 04 ELEVATIONS 02
4 1:100 Scale:
As Shown @ A3 Size Date: 18.10.2020
Status: Checked By: NPH
CD
Project No: Drawing No.:
CDP107 SD08
Document Set ID: 21315566 Plot Date: 19/10/2020
Version: 1, Version Date: 10/12/2020
Page 8
- Z:\14_Nigel's Backup\STUFF\107\LOT 107 WKG
DWG'S Stage 1 Rev D 201016.pln
NOOSA COUNCIL
APPROVED PLAN REVISION A
MCU20/0074 7 DEC 2020
ABODE SOLUTIONS
dp dp Design & Drafting
0400 799 146
A: 59.07 m2
A: 12.39 m2
A: 10.56 m2
dp
Colorbond metal sheet roof A: 58.54 m2
A: 33.76 m2
dp
dp
at 14° pitch
A: 16.76 m2
A: 65.27 m2
The designs and drawings shown on these plans
are copyrighted and remain the property of
dp dp Abode Solutions, Unauthorized copy/distribution
of these plans is prohibited.
Client Name
Total roof sheet area = 256.34m²
Total gutter length(Megaflow HF 150 Quad) = 63.560m
N Mr M Tarrant
Project Name
Proposed New Residence
Lot 107, Tewantin Road,,
Cooroy, Qld, 4563
Downpipes - not located more than 1.2m from valleys as required by
BCA, section 3.5.2.5 (c). Drawing Title:
ROOF PLAN
1 Roof Plan
1:100 Scale:
As Shown @ A3 Size Date: 18.10.2020
Status: Checked By: NPH
CD
Project No: Drawing No.:
CDP107 SD09
Document Set ID: 21315566 Plot Date: 19/10/2020
Version: 1, Version Date: 10/12/2020
Page 9
- Z:\14_Nigel's Backup\STUFF\107\LOT 107 WKG
DWG'S Stage 1 Rev D 201016.pln
NOOSA COUNCIL
APPROVED PLAN
Height
REVISION A
MCU20/0074 7 DEC 2020 8.5m Max.
Colorbond metal sheet roof @ 14° pitch
Fixed in accordance with manufacturers specification
PREFABRICATED TIMBER ROOF TRUSSES TO BE
FIXED IN A/W MANURFACTURE'S SPECIFICATIONS,
Bulkhead ABODE SOLUTIONS
Design & Drafting
0400 799 146
2,700 CL
2,100 JL
Terrace Kitchen Dining Half height wall
Mastersuite
Subfloor as per Structural
Engineers drawings
Front boundary
RL - 119.40 RL - 119.40
Rear boundary
2,400 CL
2,100 JL
Rumpus
3,600
Garage
RL - 116.70 RL - 116.70
Driveway and FGL
crossover as per Civil
Engineer's drawings NGL
RL - 115.50 RL - 115.50
1,500 1,500 5,400 1,500
1 IN 8 1 IN 6 1 IN 5 1 IN 8 CONCRETE SLAB & FOOTINGS TO BE CONSTRUCTED
Roll Over IN ACCORDANCE WITH ENGINEER'S SPECIFICATIONS
RL - 114.20
9,900
1 Section/Driveway
1:100
Water Conservation
PERFORMANCE CRITERIA
The volume of water used in toilet cisterns in a new Class 1 building and a sole-occupancy of an
Materials
existing class 2 building where toilets are replaced dnot exceed the volume of necessary for the Roofing COLORBOND SHEET METAL ROOF - PITCH AS PER ELEVATIONS
proper funcioning and operation of the toilet Roof Trusses ENGINEER DESIGNED ROOF TRUSSES - PITCH AS PER ELEVATIONS
Where the following symbol appears on any part of the attached documentation, the relevant
contractor must ensure that the guidelines for Water Conservation are adhered to, as outlined Ceiling Battens 22mm TOP HAT CEILING BATTENS INTERNALLY TO HOUSE
below in "Acceptable Solutions" 35x42mm AIR DRIED PINE CEILING BATTENS TO EXTERNAL CEILINGS & SOFFITTS
FIX AT MAX. 450mm CRS.
ACCEPTABLE SOLUTIONS Roof Battens 50mm TOP HAT ROOF BATTENS BATTENS AT 900mm CRS. & 450mm CRS. AT EDGES
In a new Class 1 building and a sole-occupancy unit of a new Class 2 building, and in an
existing class 1 building or a sole-occupancy unit of an existing Class 2 building where toilets
Insulation 65mm ANTICON ROOF INSULATION FIXED IN ACCORDANCE WITH MANUFACTURES SPECIFICATIONS
are replaced, toilet cisterns have dual flush capability that does not exceed 6 litres on full flush Gutters 'LYSAGHT' 150mm WIDE QUAD GUTTERS OR SIMILAR
and 3 litres on half flush Fascias METAL COLORBOND FASCIAS & BARGE BOARDS
Soffits 'JAMES HARDIES' ECLIPSA OR HARDIFLEX EAVES LININGS OR SIMILAR
RELEVANT CONTRACTORS COMPLIANCE - WATER CONSERVATION
Wall Framing EXTERNAL WALLS-70mm MPG12 STUD WALL FRAMING
NOTE TO RELEVANT CONTRACTOR: please list the product(s) used that conform to the
INTERNAL WALLS-70mm MPG12 STUD WALL FRAMING The designs and drawings shown on these plans
"Acceptable Solutions" as described above. are copyrighted and remain the property of
External LIGHTWEIGHT CLADDING PRODUCT - AS DESIGNATED ON ELEVATIONS
Abode Solutions, Unauthorized copy/distribution
Hot Water Supply Wall Cladding of these plans is prohibited.
Internal 10mm PLASTERBOARD WALL & CEILING LININGS
Client Name
PERFORMANCE CRITERIA Wall Linings 6mm VILLABOARD TO WET AREA WALLS
A new class 1 building must use hot water systems that have a low greenhouse gas emissions impact. Mr M Tarrant
Flooring ENGINEER DESIGNED CONCRETE SLAB
Project Name
Where the following symbol HWS appears on any part of the attached documentation,
the relevant contractor must ensure that the guidelines for Hot Water Supply are adhered to, Floor Coverings REFER TO FLOOR PLAN
as relevant contractor must ensure that the guidelines for Hot Water Supply are adhered to,
Proposed New Residence
as outlined below in "Acceptable Solutions". Lot 107, Tewantin Road,,
Entry Door SOLID CORE 2040 X 820 AS PER SPEC
Cooroy, Qld, 4563
Internal Doors HAG 12 HOLLOW CORE
Acceptable Solutions Cornice 90mm CORNICES
In a new Class 1 building, a hot water supply is provided by:
(a) A heat pump or a solar hot water system that is eligible to receive: Drawing Title:
(i) In a building with 3 or more bedrooms, at least 22 Renewable Energy
Certificates; or SECTION
(ii) In a building with 1 or 2 bedrooms, at least 14 Renewable Energy Certificates;
or
Scale:
(b) A gas hot water system with a five star energy rating. As Shown @ A3 Size Date: 18.10.2020
Note: Renewable Energy Certificates are issued under the Commonwealth Government's
Status: Checked By: NPH
Mandatory Renewable Energy Target. CD
RELEVANT CONTRACTORS COMPLIANCE - HOT WATER SUPPLY Project No: Drawing No.:
NOTE TO RELEVANT CONTRACTOR: please list the product(s) used that conform to the
"Acceptable Solutions" as described above.
CDP107 SD10
Document Set ID: 21315566 Plot Date: 19/10/2020
Version: 1, Version Date: 10/12/2020
Page 10
-
NOOSA COUNCIL Z:\14_Nigel's Backup\STUFF\107\LOT 107 WKG
STAGE 1
DWG'S Stage 1 Rev D 201004.pln
APPROVED PLAN
MCU20/0074 7 DEC 2020 REVISION A
2.00 m
132°48'00"
24.996 1.8m High timber pailing fence
Garden Bed
storage location
ABODE SOLUTIONS
Refuse bins
Bin
Design & Drafting
Bin
0400 799 146
"A" Grade Turf Clothesline A: 67.73 m2
A: 9.89 m2 Guest
Parking Gate
Garden dp dp
A: 21.24 m2
Bed
1.8m High timber pailing fence
Remove existing tree
Letterbox
UNIT 1 LANDSCAPE LEGEND
"NATIVE STYLE" PLANT SELECTIONS
NB. Plants will be selected from list subject to availability
Native
OLIVINE LANE
A: 3.92 m2 Banksia Integrifolia
EASEMENT
Acronychia Imperforata
42°48'10"
42°48'10"
Garden Bed
20.117
20.117
dp
Syzygium Australe
Garden Bed Xanthorea Sp
dp
5,500
Concrete driveway to Austromyrtus Dulcis
Council requirements
dp Callistemon
Driveway Paths & Courtyards Grevillea
A: 163.96 m2
Lomandra Hystrix
Water Housia Floribunda
Minimum 6 x 45 litre trees
dp
Letterbox to be pillar style rendered and painted finish
with dual inserts.
UNIT 2
The designs and drawings shown on these plans
A: 8.86 m2 are copyrighted and remain the property of
Abode Solutions, Unauthorized copy/distribution
Garden
"A" Grade Turf of these plans is prohibited.
Bed dp dp
Gate Client Name
A: 28.65 m2
Clothesline Mr M Tarrant
Bin Bin Project Name
Refuse bins Proposed New Residence
132°48'00"
storage location
1.8m High timber pailing fence
Garden Bed Lot 107, Tewantin Road,,
Cooroy, Qld, 4563
24.996
114.0 115.0 116.0 117.0
N Drawing Title:
LANDSCAPE PLAN
LOT 107
Landscape Plan Scale:
1 1:100 Area = 502.84m² As Shown @ A3 Size
Status:
Date: 05.10.2020
Checked By: NPH
CD
Total Soft Landscaping = 140.29m² Project No: Drawing No.:
CDP107 SD14
Document Set ID: 21315566 Plot Date: 6/10/2020
Version: 1, Version Date: 10/12/2020
Page 11
-
NOOSA COUNCIL
APPROVED PLAN
ADJACENT LOT
PROPERTY BOUNDARY MCU20/0074 7 DEC 2020
SEWER MANHOLE
EXISTING KERB SL 118.16
AND CHANNEL DS IL 116.635
EXISTING STONE PITCHED CONCRETE EXISTING
CHANNEL TO BE REMOVED. 1 Carport DEPTH OF SEWER 1.25m AT BOUNDARY PROPOSED U/G SERVICES TO NEW DWELLING TELSTRA PIT
37 APPROX. IL 116.597 (WATER, TELECOM, ELECTRICITY)
4. 2.00 2.50
11 VERGE
GUEST PARKING EXISTING POWER POLE
PROPOSED PIPE
LOW WALL ON
CORNER REQUIRED
PROPOSED WATER METERS FOR NEW
5.00
DWELLING ADJACENT EXISTING
CONCRETE DROP INLET TO BE REMOVED. Grass
PROPOSED STORMWATER MANHOLE AND PIPE cells
EXISTING WATER METER LOCATION.
TO GULLY INSTALLED ON KERB ALIGNMENT
100mm AC WATER MAIN LOCATED IN
OPPOSITE VERGE OF TEWANTIN ROAD
APPROX. DIRECTION
OF 300Ø RCP
9
. 13
1 14
UNIT 1
ROOFWATER 5
KERB ADAPTORS 2.0
ROAD CROSSING LOCATION
12
TO BE CONFIRMED IN OPW
FOR UNDERBORE.
TEWANTIN ROAD
9.90
OLIVINE LANE
EXISTING
PROPOSED DWELLING DWELLING
6.00 (W1)
5.00 (W2)
6.00 (W3)
GARAGE FFL 115.500
A GROUND FLOOR FFL 116.7
02 9.90
6 DEVELOPER TO PROVIDE GRAVITY SEWER
93 ARRANGEMENT FROM PROPOSED DWELLING TO
3.
11 A STANDARD UNITYWATER GRAVITY HOUSE
CONNECTION INTO EXISTING SEWER MAIN
EXISTING ROAD CROWN
UNIT 2 EXISTING 150mm AC SEWER MAIN
ROOFWATER LOCATION OF EXISTING HOUSE SEWER
KERB ADAPTORS CONNECTION TO BE CONFIRMED ON SITE
EXISTING VEHICLE
ROAD PAVEMENT
CROSSOVER
WIDENING AND SEAL
FLOW
3
.76
1 13
EXISTING VEHICLE CROSSOVER LOCATED EXISTING DWELLING STORMWATER TO
BETWEEN PROPERTIES TO BE REMOVED OR DRAINAGE PIT. PIPE TO OLIVINE LANE AND
RELOCATED WEST FOR ADJACENT LOT. Dilapidated Shed OUTLET TO KERB ADAPTORS
2m WIDE STRIP OF LAND EXTENDING THE
FULL FRONTAGE TO BE DEDICATED TO
COUNCIL AS ROAD RESERVE DEPTH OF SEWER 1.27m AT BOUNDARY
CONCRETE KERB AND CHANNEL APPROX. IL 115.715
WITH STONE PITCHING IN CHANNEL
BATTER SLOPE TO AREA
5 62
3.
11
IF REQUIRED REINSTATE RURAL VEHICLE
ADJACENT LOT
CROSSOVER FOR ADJACENT LOT.
PROPERTY BOUNDARY
SEWER CONTINUES 59m FROM SUBJECT
LOT BOUNDARY. LEVELS AT MANHOLE:
SL 114.204
US IL 113.177
SURVEY DATA
SURVEYED BY 'CADCON INTERNATIONAL EDGE OF BUILDING
PROPERTY BDY
PTY LTD' DATED 30/09/2020. PLAN
ROAD CROWN
REFERENCE 208522-01-01
KERB FACE
GARAGE FFL 115.50
NOTES: LEGEND OLIVINE
1. DRAWINGS TO BE READ IN CONJUNCTION WITH ALL RELEVANT
DOCUMENTATION, SPECIFICATIONS AND STANDARD DRAWINGS.
PROPOSED ROAD PAVEMENT LANE DRIVEWAY
SURFACE PROFILE SITE DATA
2. DIMENSIONS IN METRES UNLESS NOTED OTHERWISE (U.N.O). DO NOT PROPOSED TURF/LANDSCAPING 2.50 @ 5%
SCALEFROM DRAWINGS. USE PRINTED DIMENSIONS ONLY.
1 ON 3 MAX LANDSCAPING ADJACENT
PARKING BEHIND SECTION GUEST PARKING RPD
PROPOSED CONCRETE DRIVEWAY AND VEHICLE CROSSOVER
3. BUILDING AND LANDSCAPE DESIGN BY 'ABODE SOLUTIONS'.
IN ACCORDANCE WITH IPWEA STD DWG RS-049 & RS-050
LOT 107 ON C 5604
4. BUILDING FINISHED FLOOR LEVEL (FFL) SUBJECT TO UNITYWATER REVIEW. APPROX. RL 113.77 PARISH:
POPOSED STORMWATER
5. DRIVEWAY PROFILE CHECKED IN ACCORDANCE WITH AS/NZS2890.1 FOR A PROPOSED RETAINING WALLS BEHIND SECTION
COUNTY:
B99 VEHICLE.
EXISTING SEWER
EXISTING U/G TELECOM SITE AREA
EXISTING O/H ELECTRICITY 1012m2 TOTAL
EXISTING WATER DBYD 3.46 NOM 1.50 1.50 5.40 1.50
EXISTING STORMWATER DBYD VARIES 1 IN 8 1 IN 6 1 IN 5 1 IN 8 LOCAL AUTHORITY
(CROSSFALL EXTENSION) ROLL OVER NOOSA SHIRE COUNCIL
EXISTING FENCE
EXISTING CONTOUR MAJOR SECTION A
ZONE CLASSIFICATION
EXISTING CONTOUR MINOR SCALE 1:50 -
MEDIUM DENSITY RESIDENTIAL
North Point Scale Horiz. Datum Client Consultant Project Drawing
LOCAL Drawn GM Drawing No. Rev No.
0 2.5 5 MIDSON CONSTRUCTIONS ABN 51 640 311 842 33 TEWANTIN ROAD CIVIL SITE LAYOUT AND DRIVEWAY
m
Vert. Datum (QLD) PTY LTD SUNSHINE COAST COOROY, QLD, 4563 Design GM CROSSOVER SECTION
A1 1:100
0 1.25 2.5
m
AHD BRISBANE
GOLD COAST
MULTIPLE DWELLINGS DEVELOPMENT Check LS
200437-C-00001 B
B GENERAL UPDATES 19.10.20 LS RL Datum MCU APPLICATION Approved Signed
A FOR APPROVAL 07.10.20 LS A1 1:50 OPM 24963 COPYRIGHT © All rights reserved. Sheet
Rev Revision Description Date Approved RL 125.924
This work is copyright and cannot be reproduced
or copied in any form without the prior consent
Date 07.10.20 L.SWANN
RPEQ 21223
Status FOR APPROVAL
Size A1
Document Set ID: 21315566
Version: 1, Version Date: 10/12/2020