Original source · versioned page text
Subdivision Plans
- Z:\14_Nigel's Backup\STUFF\107\LOT 107 WKG
DWG'S Stage 1 Rev D 201016.pln
NOOSA COUNCIL
APPROVED PLAN
Height
REVISION A
MCU20/0074 7 DEC 2020 8.5m Max.
Colorbond metal sheet roof @ 14° pitch
Fixed in accordance with manufacturers specification
PREFABRICATED TIMBER ROOF TRUSSES TO BE
FIXED IN A/W MANURFACTURE'S SPECIFICATIONS,
Bulkhead ABODE SOLUTIONS
Design & Drafting
0400 799 146
2,700 CL
2,100 JL
Terrace Kitchen Dining Half height wall
Mastersuite
Subfloor as per Structural
Engineers drawings
Front boundary
RL - 119.40 RL - 119.40
Rear boundary
2,400 CL
2,100 JL
Rumpus
3,600
Garage
RL - 116.70 RL - 116.70
Driveway and FGL
crossover as per Civil
Engineer's drawings NGL
RL - 115.50 RL - 115.50
1,500 1,500 5,400 1,500
1 IN 8 1 IN 6 1 IN 5 1 IN 8 CONCRETE SLAB & FOOTINGS TO BE CONSTRUCTED
Roll Over IN ACCORDANCE WITH ENGINEER'S SPECIFICATIONS
RL - 114.20
9,900
1 Section/Driveway
1:100
Water Conservation
PERFORMANCE CRITERIA
The volume of water used in toilet cisterns in a new Class 1 building and a sole-occupancy of an
Materials
existing class 2 building where toilets are replaced dnot exceed the volume of necessary for the Roofing COLORBOND SHEET METAL ROOF - PITCH AS PER ELEVATIONS
proper funcioning and operation of the toilet Roof Trusses ENGINEER DESIGNED ROOF TRUSSES - PITCH AS PER ELEVATIONS
Where the following symbol appears on any part of the attached documentation, the relevant
contractor must ensure that the guidelines for Water Conservation are adhered to, as outlined Ceiling Battens 22mm TOP HAT CEILING BATTENS INTERNALLY TO HOUSE
below in "Acceptable Solutions" 35x42mm AIR DRIED PINE CEILING BATTENS TO EXTERNAL CEILINGS & SOFFITTS
FIX AT MAX. 450mm CRS.
ACCEPTABLE SOLUTIONS Roof Battens 50mm TOP HAT ROOF BATTENS BATTENS AT 900mm CRS. & 450mm CRS. AT EDGES
In a new Class 1 building and a sole-occupancy unit of a new Class 2 building, and in an
existing class 1 building or a sole-occupancy unit of an existing Class 2 building where toilets
Insulation 65mm ANTICON ROOF INSULATION FIXED IN ACCORDANCE WITH MANUFACTURES SPECIFICATIONS
are replaced, toilet cisterns have dual flush capability that does not exceed 6 litres on full flush Gutters 'LYSAGHT' 150mm WIDE QUAD GUTTERS OR SIMILAR
and 3 litres on half flush Fascias METAL COLORBOND FASCIAS & BARGE BOARDS
Soffits 'JAMES HARDIES' ECLIPSA OR HARDIFLEX EAVES LININGS OR SIMILAR
RELEVANT CONTRACTORS COMPLIANCE - WATER CONSERVATION
Wall Framing EXTERNAL WALLS-70mm MPG12 STUD WALL FRAMING
NOTE TO RELEVANT CONTRACTOR: please list the product(s) used that conform to the
INTERNAL WALLS-70mm MPG12 STUD WALL FRAMING The designs and drawings shown on these plans
"Acceptable Solutions" as described above. are copyrighted and remain the property of
External LIGHTWEIGHT CLADDING PRODUCT - AS DESIGNATED ON ELEVATIONS
Abode Solutions, Unauthorized copy/distribution
Hot Water Supply Wall Cladding of these plans is prohibited.
Internal 10mm PLASTERBOARD WALL & CEILING LININGS
Client Name
PERFORMANCE CRITERIA Wall Linings 6mm VILLABOARD TO WET AREA WALLS
A new class 1 building must use hot water systems that have a low greenhouse gas emissions impact. Mr M Tarrant
Flooring ENGINEER DESIGNED CONCRETE SLAB
Project Name
Where the following symbol HWS appears on any part of the attached documentation,
the relevant contractor must ensure that the guidelines for Hot Water Supply are adhered to, Floor Coverings REFER TO FLOOR PLAN
as relevant contractor must ensure that the guidelines for Hot Water Supply are adhered to,
Proposed New Residence
as outlined below in "Acceptable Solutions". Lot 107, Tewantin Road,,
Entry Door SOLID CORE 2040 X 820 AS PER SPEC
Cooroy, Qld, 4563
Internal Doors HAG 12 HOLLOW CORE
Acceptable Solutions Cornice 90mm CORNICES
In a new Class 1 building, a hot water supply is provided by:
(a) A heat pump or a solar hot water system that is eligible to receive: Drawing Title:
(i) In a building with 3 or more bedrooms, at least 22 Renewable Energy
Certificates; or SECTION
(ii) In a building with 1 or 2 bedrooms, at least 14 Renewable Energy Certificates;
or
Scale:
(b) A gas hot water system with a five star energy rating. As Shown @ A3 Size Date: 18.10.2020
Note: Renewable Energy Certificates are issued under the Commonwealth Government's
Status: Checked By: NPH
Mandatory Renewable Energy Target. CD
RELEVANT CONTRACTORS COMPLIANCE - HOT WATER SUPPLY Project No: Drawing No.:
NOTE TO RELEVANT CONTRACTOR: please list the product(s) used that conform to the
"Acceptable Solutions" as described above.
CDP107 SD10
Document Set ID: 21315566 Plot Date: 19/10/2020
Version: 1, Version Date: 10/12/2020
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original (Subdivision Plans.pdf)
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.