Original source · versioned page text
Attachment 2 - 1856-W01_W17
W M
N35
DN150 THRUST RESTRAINT
600mm LONG (FL-FL)
DI P
DN150 VALVE (FL-FL)
50
DN1
DN150 BLANK END NEW OD180 PE100 PN16 WM
NEW
NE
OD180 TEE W KER
RY
B
NDA
NEW OD180 PE100 PN16 WM DN150 THRUST RESTRAINT
BOU
600mm LONG (FL-SOC)
NE
BOUNDARY W DN150 VALVE (FL-FL)
FO
OT
PA OD180 STUB FLANGE WITH EF COUPLING
TH
DN150 THRUST RESTRAINT NEW OD180 PE100 PN16 WM
600mm LONG (FL-FL)
DN150 VALVE (FL-FL) NEW OD180 PE100 PN16 WM
CONTRACTOR
ALL THRUST BLOCKS TO BO
UN
BE IN ACCORDANCE NEW OD180 PE100 PN16 WM DA
WITH SEQ-WAT-1205-1 & DN150 BLANK END RY
SEQ-WAT-1206-1 OD180 TEE
OD180 TEE
NEW OD180 PE100 PN16 WM
CONTRACTOR
ALL THRUST BLOCKS TO
BE IN ACCORDANCE
CONNECTION DETAIL G WITH SEQ-WAT-1205-1 &
CONNECTION DETAIL F SEQ-WAT-1206-1
REFER TO DRAWING 1856-W05 REFER TO DRAWING 1856-W05
SCALE 1:50 (A3) SCALE 1:40 (A3)
PATH
M
6W
KERB
FOOT
0 P 180
LIVE
N1
PE W OD
NEW
NEW
WOR
0 RCP SW DN150 GIBAULT
NEW DN90 OD180 STUB FLANGE
10
K
NE
S BY
WITH EF COUPLING
(SOC-SOC)
UNIT
DN150 THRUST RESTRAINT
FH
Y
WAT
600mm LONG (FL-FL)
NE
EXISTING DN150 HYDRANT TO
ER
WF
REMOVED BY UNITYWATER
DN150 VALVE
DN150 TEE (FL-FL-FL)
OO
(SOC-SOC) OD180 STUB FLANGE
NEW
WITH EF COUPLING
TPA
TH
DN
DN150 GIBAULT DN150 VALVE (FL-FL)
150
CONTRACTOR
BOU
NE
oPV
DN150 THRUST RESTRAINT W
OD
OFF
ALL THRUST BLOCKS TO 600mm LONG (FL-FL) 18
NDA
C
0P
BE IN ACCORDANCE E1
LINE
PN1
0 0P
WITH SEQ-WAT-1205-1 &
RY
N1
6W
WOR
SEQ-WAT-1206-1
6W
OD180 STUB FLANGE M
KS
WITH EF COUPLING
M
DN150 THRUST RESTRAINT
M
DN150 GIBAULT 600mm LONG (FL-FL)
6W
NEW
RY
0 P 180
DA
N1
DN150 CONNECTOR DN150 VALVE (FL-FL)
PE W OD
OD
UN
(FL-SP) Y CONTRACTOR
AR
BO
180
10
ND
NE
DN150 THRUST RESTRAINT ALL THRUST BLOCKS TO
U
PE1
600mm LONG (FL-FL) BE IN ACCORDANCE
BO
WITH SEQ-WAT-1205-1 &
0
NEW
0P
SEQ-WAT-1206-1
CONNECTION DETAIL E CONNECTION DETAIL E2
N16
KER
REFER TO DRAWING 1856-W05 OD180 STUB FLANGE REFER TO DRAWING 1856-W05
WITH EF COUPLING
WM
SCALE 1:50 (A3) SCALE 1:50 (A3)
B
PROJECT: JOB NUMBER
REV DATE DESCRIPTION BY CHKD DRAWN
I GDETAL
IS SCALE APPROVED PROPOSED SUBDIVISION 1856
A 18-03-20 FOR APPROVAL MM CL AT NOOSA CIVIC, WALTER HAY DRIVE
DATUM AHD SHEET: 13 OF 17
0 10 20 30 40 50m
FOR STOCKWELL PTY LTD
DESIGN MM ................. DRAWING NUMBER REV
DRAWING TITLE:
DRAWN MM Director: CAMERON LANDRETH
SCALE 1:1000 A3
DESIGN CHECK (RPEQ 19358) p 07 5443 8285 WATERMAIN CONNECTION DETAIL PLAN W13 A
CL
e [email protected] w www.barlowshelley.com.au
DATE 18-03-20
This drawing is not to be copied or amended without written permission from
Barlow Shelley Consulting Engineers a PO Box 899, Maroochydore,4558 ABN 89 215 591 077 SHEET 2 OF 5
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file