Original source · versioned page text
Attachment 2 - 1856-W01_W17
DN150 GIBAULT
R
ATE
YW
DN150 DI PN35 WS
NIT
YU
EXISTING DN150 oPVC
SB
PN16 WM DN150 VALVE (FL-FL) WITH BLANK END
K
OR
EW
LIV
DN150 TEE (SOC-SOC-FL)
DN150 CONNECTOR (FL-SP)
FH
DN150 VALVE (FL-FL)
DN150 GIBAULT
DN250x150 OFFTAKE (FLANGED)
EXISTING FH TO BE REMOVED BY UNITYWATER
DN150 oPVC PN16 WM
LIV
EW EX DN250 WATERMAIN
OR
KSB
DN150 GIBAULT YU
NIT
YW
ATE
DN150 CONNECTOR (FL-SP) R
CONTRACTOR
DN150 THRUST RESTRAINT 600mm LONG (FL-FL) CONTRACTOR
ALL THRUST BLOCKS TO
BE IN ACCORDANCE ALL THRUST BLOCKS TO
OD180 STUB FLANGE WITH EF COUPLING
WITH SEQ-WAT-1205-1 & BE IN ACCORDANCE
SEQ-WAT-1206-1
CONNECTION DETAIL M OD180 PE100 PN16 WM WITH SEQ-WAT-1205-1 & CONNECTION DETAIL N
REFER TO DRAWING 1856-W09 SEQ-WAT-1206-1
REFER TO DRAWING 1856-W10
SCALE 1:40 (A3) SCALE 1:40 (A3)
ERB
WK
NE
RB
T H
KE
TPA
OO
WF
W
TH
NE
NE
OD180 PE100 PN16 WM
PA
OT
FO
OD180 STUB FLANGE
W
WITH EF COUPLING
NE
OD180 PE100 PN16 WM
DN150 THRUST RESTRAINT
600mm LONG (FL-FL)
DN150 VALVE (FL-FL)
DN150 TEE (FL-FL-FL)
DN150 VALVE (FL-FL)
DN150 THRUST RESTRAINT WITH BLANK END BEND WITH EF COUPLINGS
600mm LONG (FL-FL)
OD180 PE100 PN16 WM DN150 THRUST RESTRAINT 600mm LONG (FL-FL)
DN150 VALVE (FL-FL)
OD180 STUB FLANGE OD180 STUB FLANGE
OD180 PE100 PN16 WM
Y
WITH EF COUPLING WITH EF COUPLING
AR
DN150x100 TEE
D
UN
DN150 THRUST RESTRAINT WITH FH (FL-FL)
600mm LONG (FL-FL)
BO
CONTRACTOR CONTRACTOR
ALL THRUST BLOCKS TO ALL THRUST BLOCKS TO RY
DA
BE IN ACCORDANCE UN CONNECTION DETAIL L
CONNECTION DETAIL K BE IN ACCORDANCE BO
WITH SEQ-WAT-1205-1 & WITH SEQ-WAT-1205-1 & REFER TO DRAWING 1856-W07
SEQ-WAT-1206-1 REFER TO DRAWING 1856-W07
SEQ-WAT-1206-1 SCALE 1:40 (A3)
SCALE 1:40 (A3)
PROJECT: JOB NUMBER
REV DATE DESCRIPTION BY CHKD DRAWN
I GDETAL
IS SCALE APPROVED PROPOSED SUBDIVISION 1856
A 18-03-20 FOR APPROVAL MM CL AT NOOSA CIVIC, WALTER HAY DRIVE
DATUM AHD SHEET: 15 OF 17
0 10 20 30 40 50m
FOR STOCKWELL PTY LTD
DESIGN MM ................. DRAWING NUMBER REV
DRAWING TITLE:
DRAWN MM Director: CAMERON LANDRETH
SCALE 1:1000 A3
DESIGN CHECK (RPEQ 19358) p 07 5443 8285 WATERMAIN CONNECTION DETAIL PLAN W17 A
CL
e [email protected] w www.barlowshelley.com.au
DATE 18-03-20
This drawing is not to be copied or amended without written permission from
Barlow Shelley Consulting Engineers a PO Box 899, Maroochydore,4558 ABN 89 215 591 077 SHEET 4 OF 5
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take up to a minute.