Council archive · source document
Plans · 132005.307.01
Plans and drawings: the text below has words only, no drawings.
178 o 53'35"
28.087 SMH
S S S S S S suite 2
S S
46 mary street
noosaville qld 4566
po box 613
noosa heads qld 4567
telephone 07 54473255
3.0M SETBACK
facsimile 07 54473299
UP
inf [email protected]
www.ct-design.com.au
building designer licence 1016347
existing existing
This drawing is to be read in
POOL DECK STUDY
268 o55'00"
conjunction with Engineers Drawings
14.019
existing
timber decking timber & Reports.
GARAGE
concrete Construction to comply with all
2.0M SETBACK
relevant SAA & BCA Codes &
standard Bldg By-law 1975 & as
amended.
Verify all dimensions on site prior to
commencement of any works. These
drawings are not to be used for
150 scaling. Copyright for design &
timber step
drawings remain the property of
the authors.
existing
existing
FAMILY ROOM
L'DRY
timber
timber SOUTH
SFL 10.700 ELEVATION existing external laundry door to be removed,
prepare for new wall infill
existing
DP existing downpipe to be relocated
Proposed Lift existing
DRIVEWAY
concrete
ENTRY prepare area for new lift shaft construction
existing
extent shown shaded
UP
DRYING CK 1.376
T BA 357 o12'10" existing structural post to be cut back to height of existing screen
YARD SE
M once roof over removed
existing tile 3.0
ENTRY
DP existing downpipe to be relocated
SFL 10.600 confirm existing drying yard slab has been built at RL 10.600.
PORCH
80mm min below Entry FFL required for proposed lift shaft.
UP
Note! builder to confirm that existing slab will accomodate lift above
DP
STAIRS
timber
P1 - RE-ISSUED FOR REVIEW
14.12.2023
7
.8 6 0"
Project
13 '1 ROOFWATER DISCHARGE TO:
32
9
o 35
Existing Approved System
PROPOSED
ADDITION OF LIFT
•Stormwater to be discharged so as to not cause Location
erosion or nuisance to adjoining properties 30 NOOSA DUNES,
•Stormwater system to comply with AS3500 Part 3
CASTAWAYS BEACH
•All other details to Local Government Requirements
Client
HUDDART
CORROSION PROTECTION (Breaking Surf) Drawing Title
WEST
ELEVATION Dwelling to be upgraded to ensure adequate corrosion protection is provided for a EXISTING GROUND
lot within 1000m of breaking surf (approx. 210m). The following relevant sections of FLOOR PLAN
the BCA Vol. 2 2019 apply: Scale Date
- Structural Steel Part 3.4.4.4 as shown @A3 2023
- Sheet Roofing Part 3.5.1.2
Drawn By Job No:
- Masonry Structures and Masonry Accessories AS3700 & AS4773.1 & AS4773.2
SC 2317
Drawing No. Issue No.
EXISTING GROUND FLOOR PLAN 1:100 WD.201 P1
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 5 pages
Page 2
CASTAWAYS BEACH
commencement of any works. These
P1 - RE-ISSUED FOR REVIEW
conjunction with Engineers Drawings
Verify all dimensions on site prior to
30 NOOSA DUNES,
Issue No.
building designer licence 1016347
ADDITION OF LIFT
2317
Job No:
drawings remain the property of
07 54473255
07 54473299
standard Bldg By-law 1975 & as
as shown @A3 2023
GROUND FLOOR
WD.202 P1
drawings are not to be used for
scaling. Copyright for design &
Construction to comply with all
Date
relevant SAA & BCA Codes &
This drawing is to be read in
inf [email protected]
www.ct-design.com.au
noosa heads qld 4567
noosaville qld 4566
PROPOSED
PROPOSED
HUDDART
46 mary street
Drawing Title
po box 613
14.12.2023
Drawing No.
the authors.
telephone
& Reports.
facsimile
amended.
Drawn By
Location
suite 2
Project
Client
Scale
SC
1:100
installed by specialist contractor, refer to manufacturers specifications
new p/c aluminium gate to existing Drying Yard screen
proposed location of new lift machine cabinet,
new lift, installed by specialist contractor,
new rendered blockwork lift shaft, finish
new wall infill, blockwork, internal finish
refer to manufacturers specifications
new location of existing downpipe
new location of existing downpipe
new wall opening 1290w x 2300h
to match existing
to match existing
ELEVATION
SOUTH
268 o55'00"
14.019
357 o12'10"
1.376
SMH
S
2.0M SETBACK
PROPOSED GROUND FLOOR PLAN
3.0M SETBACK
S
REV DETAILS DRAWN CHECKED DATE
A ISSUED FOR APPROVAL PRAJWAL Y 08-11-2023
BUILDERS INFORMATION
DRIVEWAY
PHOENIX - STANDARD
GARAGE
SLAB / LIFT WELL LIFT SHAFT CONSTRUCTION
HUDDART RESIDENCE 1425
concrete
concrete
S
INTERNAL CERTIFICATION OF THE LIFT SLAB BY AN APPROVED ENGINEER.
MINIMUM CLEARANCE
existing
existing
ANY PIT SET DOWN SHOULD BE PROTECTED AGAINST ANY INGRESS OF
K
WATER.
1375 INDEPENDENT
AC
LIFT SHAFT LIFT WELL ENCLOSURE
BY OTHERS THE LIFT SLAB TO BE KEPT CLEAR OF RUBBISH AND WATER.
(PARENT STRUCTURE)
TB
THE LIFT PIT SLAB MUST BE LEVEL ACROSS ALL FOUR CONERS.
THE LIFT PIT MUST BE WITHIN 5MM OF WHAT HAS BEEN SPECIFIED.
E (MEASUREMENT TAKEN FROM THE HIGHEST POINT OF THE LIFT SLAB)
S
THE BUILDER MUST PROVIDE A CLEAR OPENING AT EACH LEVEL. NO
STUD OR BLOCK WALLS ARE TO BE CONSTRUCTED AT THE ENTIRE
FRONT FACE OF THE LANDINGS UNTIL AFTER THE LIFT IS IN PLACE AND
M
SECURED.
3.0
SHOULD ANY PHONE OR ELECTRICAL WIRING BE RUN WITHIN THE LIFT
.8 6 0"
SLAB / LIFT WELL
WELL IT MUST BE ENCLOSED IN CONDUIT AND SECURED AWAY FROM
1540
'1
MOVING PARTS OF THE LIFT.
INTERNAL
o 35
MINIMUM CLEARANCE
LIFT WELL
7
THE LIFT WELL SHALL HAVE NO SERVICES SUCH AS WATER PIPES,
S
2500 AIR-CONDITIONING OR VACCUM DUCTS RUN WITHIN IT.
2300 200 1,600 200
TOP OF SHAFT
LIFT WELL
9
MINIMUM 1490 THE LIFT WELL SHOULD BE PLUMB FROM THE TOP TO THE BOTTOM
OPENING
13
32
LIFT SHAFT WITH A MINIMUM CLEARANCE OF 25MM AT ALL POINTS TO THE LIFT
SHAFT.
178 o 53'35"
28.087
step
200
150
TOP OF SHAFT
DP
SFL 10.600
D'YARD
L'DRY
timber
existing
T1
timber
S
tile
2990
FFL - FFL
1,540
LIFT
2300
LIFT WELL
new
OPENING
STUDY
timber
existing
DP
CLIENT APPROVAL
PIT
SIDE SECTION GROUND FLOOR FIRST FLOOR
SIGNATURE
/ /
aussi el ft s
200
80
LIFT SHAFT/ WELL 1290
1,290 SCALE: A3 DRAWN PRAJWAL Y 08-11-2023
TYPICAL LIFT WELL DIMENSIONS: MM (UNLESS SPECIFIED) CHECKED 08-11-2023
OPENING CLIENT NAME DRAWING NUMBER REV
ELEVATION
HUDDART RESIDENCE 882251023-A A
PORCH
S
ENTRY
SHEET 4 OF 5
ENTRY
COPYRIGHT 2021 BY AUSSIE LIFTS PTY LTD. 12 ACHIEVEMENT CRES. ACACIA RIDGE. QLD 4110. TEL: (07) 3274 4211. THIS DRAWING REMAINS THE PROPERTY OF AUSSIE LIFTS & NO PART SHALL BE COPIED OR USED WITHOUT THE PERMISSION OF THE AFORMENTIONED COMPANY
WEST
existing
existing
UP
FAMILY ROOM
S
POOL DECK
UP
timber decking
STAIRS
SFL 10.700
timber
timber
existing
existing
UP
S
Page 3
suite 2
46 mary street
noosaville qld 4566
po box 613
noosa heads qld 4567
telephone 07 54473255
3.0M SETBACK
facsimile 07 54473299
existing inf [email protected]
DECK
tile www.ct-design.com.au
building designer licence 1016347
existing
This drawing is to be read in
DECK conjunction with Engineers Drawings
timber decking existing existing & Reports.
KITCHEN BEDROOM 1
Construction to comply with all
2.0M SETBACK
timber timber relevant SAA & BCA Codes &
standard Bldg By-law 1975 & as
amended.
Verify all dimensions on site prior to
commencement of any works. These
drawings are not to be used for
scaling. Copyright for design &
drawings remain the property of
existing the authors.
ENSUITE 1
existing existing
existing
timber
LIVING DINING DRESSING
timber timber timber
remove existing awning to Dressing Room window
and prepare for new awning to new window
SFL 13.700 remove existing Dressing Room window and prepare for
DP
new smaller window and wall infill
existing downpipe to be relocated
existing window to be removed,
UP K
AC prepare for new lift shaft opening
E TB
S prepare area for new lift shaft construction
M
3.0 extent shown shaded
existing
DP
remove existing downpipe
awning roof
below
remove existing roof to drying yard below
UP
STAIRS DP
timber
P1 - RE-ISSUED FOR REVIEW
14.12.2023
Project
PROPOSED
ADDITION OF LIFT
Location
30 NOOSA DUNES,
CASTAWAYS BEACH
Client
HUDDART
Drawing Title
EXISTING FIRST
FLOOR PLAN
Scale Date
as shown @A3 2023
Drawn By Job No:
SC 2317
Drawing No. Issue No.
EXISTING FIRST FLOOR PLAN 1:100 WD.203 P1
Page 4
CASTAWAYS BEACH
commencement of any works. These
P1 - RE-ISSUED FOR REVIEW
conjunction with Engineers Drawings
Verify all dimensions on site prior to
30 NOOSA DUNES,
Issue No.
PROPOSED FIRST
building designer licence 1016347
ADDITION OF LIFT
2317
Job No:
drawings remain the property of
07 54473255
07 54473299
standard Bldg By-law 1975 & as
as shown @A3 2023
WD.204 P1
drawings are not to be used for
scaling. Copyright for design &
Construction to comply with all
Date
relevant SAA & BCA Codes &
This drawing is to be read in
inf [email protected]
www.ct-design.com.au
noosa heads qld 4567
FLOOR PLAN
noosaville qld 4566
PROPOSED
HUDDART
46 mary street
Drawing Title
po box 613
14.12.2023
Drawing No.
the authors.
telephone
& Reports.
facsimile
amended.
Drawn By
Location
suite 2
Project
Client
Scale
SC
1:100
new window to match existing Ensuite 1 window
new wall opening to lift entry 1290w x 2300h
new lift, installed by specialist contractor,
new rendered blockwork lift shaft, finish
new wall infill, timber framed, internal &
refer to manufacturers specifications
to match existing Ensuite 1 awning
external finishes to match existing
new location of existing downpipe
new location of existing downpipe
new aluminium awning (over)
to match existing
2.0M SETBACK
PROPOSED FIRST FLOOR PLAN
3.0M SETBACK
BEDROOM 1
ENSUITE 1
REV DETAILS DRAWN CHECKED DATE
A ISSUED FOR APPROVAL PRAJWAL Y 08-11-2023
BUILDERS INFORMATION
DECK
timber
PHOENIX - STANDARD
existing
existing
LIFT SHAFT CONSTRUCTION
timber
SLAB / LIFT WELL
existing
HUDDART RESIDENCE
tile
1425
INTERNAL CERTIFICATION OF THE LIFT SLAB BY AN APPROVED ENGINEER.
MINIMUM CLEARANCE
ANY PIT SET DOWN SHOULD BE PROTECTED AGAINST ANY INGRESS OF
K
WATER.
1375 INDEPENDENT
AC
LIFT SHAFT LIFT WELL ENCLOSURE
BY OTHERS THE LIFT SLAB TO BE KEPT CLEAR OF RUBBISH AND WATER.
(PARENT STRUCTURE)
TB
THE LIFT PIT SLAB MUST BE LEVEL ACROSS ALL FOUR CONERS.
THE LIFT PIT MUST BE WITHIN 5MM OF WHAT HAS BEEN SPECIFIED.
(MEASUREMENT TAKEN FROM THE HIGHEST POINT OF THE LIFT SLAB)
SE
THE BUILDER MUST PROVIDE A CLEAR OPENING AT EACH LEVEL. NO
STUD OR BLOCK WALLS ARE TO BE CONSTRUCTED AT THE ENTIRE
M
FRONT FACE OF THE LANDINGS UNTIL AFTER THE LIFT IS IN PLACE AND
SECURED.
3.0
SHOULD ANY PHONE OR ELECTRICAL WIRING BE RUN WITHIN THE LIFT
SLAB / LIFT WELL
WELL IT MUST BE ENCLOSED IN CONDUIT AND SECURED AWAY FROM
1540
MOVING PARTS OF THE LIFT.
INTERNAL
MINIMUM CLEARANCE
LIFT WELL THE LIFT WELL SHALL HAVE NO SERVICES SUCH AS WATER PIPES,
2500 AIR-CONDITIONING OR VACCUM DUCTS RUN WITHIN IT.
2300
TOP OF SHAFT
LIFT WELL
MINIMUM 1490 THE LIFT WELL SHOULD BE PLUMB FROM THE TOP TO THE BOTTOM
OPENING
LIFT SHAFT WITH A MINIMUM CLEARANCE OF 25MM AT ALL POINTS TO THE LIFT
DRESSING
SHAFT.
timber
existing
1,600 200
200
TOP OF SHAFT
DP
DP
T1
2990
FFL - FFL
1,540
LIFT
2300
LIFT WELL
new
OPENING
KITCHEN
DP
timber
existing
CLIENT APPROVAL
PIT
80
SIDE SECTION GROUND FLOOR FIRST FLOOR
SIGNATURE
/ /
aussi el ft s
LIFT SHAFT/ WELL 1290
1,290 SCALE: A3 DRAWN PRAJWAL Y 08-11-2023
TYPICAL LIFT WELL DIMENSIONS: MM (UNLESS SPECIFIED) CHECKED 08-11-2023
OPENING CLIENT NAME DRAWING NUMBER REV
awning roof
HUDDART RESIDENCE 882251023-A A
SHEET 4 OF 5
existing
COPYRIGHT 2021 BY AUSSIE LIFTS PTY LTD. 12 ACHIEVEMENT CRES. ACACIA RIDGE. QLD 4110. TEL: (07) 3274 4211. THIS DRAWING REMAINS THE PROPERTY OF AUSSIE LIFTS & NO PART SHALL BE COPIED OR USED WITHOUT THE PERMISSION OF THE AFORMENTIONED COMPANY
below
DINING
timber
existing
SFL 13.700
timber decking
UP
STAIRS
timber
DECK
existing
UP
LIVING
timber
existing
Page 5
suite 2
46 mary street
RL 16.400 LIVING CEILING
noosaville qld 4566
po box 613
existing downpipe to be relocated noosa heads qld 4567
LIVING/DINE
2,700
telephone 07 54473255
facsimile 07 54473299
existing roof over Drying Yard to be removed
RL 13.700 FIRST FLOOR inf [email protected]
existing downpipe to be relocated
www.ct-design.com.au
existing external laundry door to be removed,
prepare for new wall infill building designer licence 1016347
3,000
existing downpipe to be removed
ENTRY DRYING GARAGE This drawing is to be read in
existing structural post to be cut down
conjunction with Engineers Drawings
to height of existing Drying Yard screen & Reports.
RL 10.700 GROUND FLOOR existing aluminium screen shown hidden (dashed) for clarity
Construction to comply with all
RL 10.600 DRYING YARD relevant SAA & BCA Codes &
100
confirm existing drying yard slab has been built at RL 10.600. standard Bldg By-law 1975 & as
80mm below Entry FFL required for proposed lift shaft. amended.
Note! builder to confirm that existing slab will accomodate lift above Verify all dimensions on site prior to
commencement of any works. These
drawings are not to be used for
scaling. Copyright for design &
drawings remain the property of
the authors.
EXISTING WEST ELEVATION 1:100
RL 16.400 LIVING CEILING
new roof over lift shaft - existing roof sheeting, rafters,
gutter & fascia to be extended to accomodate
new blockwork lift shaft, finish to match existing
LIVING/DINE LIFT
2,700
- rendered with expressed joint every 400mm
new location of existing downpipe
P1 - RE-ISSUED FOR REVIEW
new location of existing downpipe 14.12.2023
RL 13.700 FIRST FLOOR Project
existing structural post cut back to height
PROPOSED
of existing p/c aluminium screen ADDITION OF LIFT
proposed location of new lift machine cabinet, Location
3,000
ENTRY DRYING GARAGE
installed by specialist contractor, refer to manufacturers specifications 30 NOOSA DUNES,
CASTAWAYS BEACH
existing aluminium screen shown hidden (dashed) for clarity Client
RL 10.700 GROUND FLOOR
RL 10.600 DRYING YARD
HUDDART
100
Drawing Title
WEST ELEVATIONS
Scale Date
as shown @A3 2023
Drawn By Job No:
SC 2317
PROPOSED WEST ELEVATION 1:100 Drawing No. Issue No.
WD.501 P1
Page 6
remove existing awning to Dressing Room window
and prepare for new awning to new window suite 2
46 mary street
RL 16.400 LIVING CEILING noosaville qld 4566
existing downpipe to be relocated
po box 613
noosa heads qld 4567
remove existing roof to drying yard below
2,700
remove existing window and prepare for telephone 07 54473255
new lift shaft opening facsimile 07 54473299
RL 13.700 FIRST FLOOR inf [email protected]
existing structural post to be cut down to
www.ct-design.com.au
height of existing aluminium screen
building designer licence 1016347
existing downpipe to be removed
3,000
DRYING YARD GARAGE This drawing is to be read in
existing aluminium screen shown hidden (dashed) for clarity conjunction with Engineers Drawings
& Reports.
RL 10.700 GROUND FLOOR Construction to comply with all
relevant SAA & BCA Codes &
RL 10.600 DRYING YARD confirm existing drying yard slab has been built at RL 10.600.
100
standard Bldg By-law 1975 & as
80mm min below Entry FFL required for proposed lift shaft. amended.
Note! builder to confirm that existing slab will accomodate lift above
Verify all dimensions on site prior to
commencement of any works. These
drawings are not to be used for
scaling. Copyright for design &
drawings remain the property of
the authors.
EXISTING SOUTH ELEVATION 1:100
new aluminium awning to match existing
RL 16.400 LIVING CEILING
new location of existing downpipe
new blockwork lift shaft, finish to match existing
shaft min ht
- rendered with expressed joint every 400mm
2,700
2,500
new location of existing downpipe
P1 - RE-ISSUED FOR REVIEW
new p/c aluminium gate to existing screen 14.12.2023
RL 13.700 FIRST FLOOR (entry porch side of Drying Yard)
Project
PROPOSED
existing structural post cut back to height
of existing p/c aluminium screen
ADDITION OF LIFT
Location
3,000
DRYING YARD GARAGE 30 NOOSA DUNES,
proposed location of new lift machine cabinet,
installed by specialist contractor, refer to manufacturers specifications CASTAWAYS BEACH
Client
RL 10.700 GROUND FLOOR existing aluminium screen shown hidden (dashed) for clarity
RL 10.600 DRYING YARD
HUDDART
100
Drawing Title
SOUTH ELEVATIONS
Scale Date
as shown @A3 2023
Drawn By Job No:
SC 2317
PROPOSED SOUTH ELEVATION 1:100 Drawing No. Issue No.
WD.502 P1