Appendix C - Code Assessment
Bushfire Hazard Overlay Code
PO3 AO3.1 AO3.1 – Not Applicable
Development provides an adequate water supply Premises are connected to the reticulated water
for fire fighting purpose which is reliable, safely supply.
located and freely accessible.
Editor's note—For reconfiguring a lot, water supply
needs to provide for a minimum flow and pressure of
10 litres a second at 200kPa at all times for fire
fighting purposes.
OR
AO3.2 AO3.2 – Complies
Where there is no available reticulated water supply, The premises has access to dams located western
the premises has: portion of the site that have water volumes greater that
5000L.
a) an accessible dam, swimming pool or water
tank available for fire fighting purposes with an
onsite water volume of not less than 5,000
litres; and
b) a water supply outlet pipe 50 millimetres in
diameter fitted with a standard fire brigade
fitting connected to the water supply (other than
where the water supply is in a swimming pool or
dam).
Editor’s Note—Water supply capacity for fire fighting
purposes is in addition to water supply capacity for
other uses and activities on the premises.
Essential Community Infrastructure
PO4 AO4.1 PO4.1 – 4.2 – Not Applicable
Essential community infrastructure is able to function Development involving essential community
effectively during and immediately after bushfire events. infrastructure is not located within a medium or high
bushfire hazard area.