Original source · versioned page text
Appendix C - Code Assessment
Flood Hazard Overlay Code
times of flood.
Editor's Note— Businesses should ensure that
necessary emergency and continuity plans are in place
to account for the potential need to evacuate personnel
and to relocate property prior to a flood event.
Essential network infrastructure
PO8 AO8 AO8 – Not Applicable
Essential network infrastructure maintains effective Essential network infrastructure that is likely to fail to
function during and immediately after flood and storm function or may result in contamination when inundated
tide inundation events.
by flood water (e.g. water supply pipeline air valves and
the like) is located above the DFE level (or where
the DFE has not been modelled for the area, above the
highest recorded flood level for the area).
Essential community infrastructure
PO9 AO9.1 AO9.1 – Not Applicable
Essential community infrastructure is able to function Essential community infrastructure is sited and
effectively during and immediately after flood events. constructed to ensure that flood levels comply with flood
immunity requirements specified in Table 8.2.6.4.
AO9.2
AO9.2 – Not Applicable
Essential community infrastructure which is located
below the specified flood immunity requirements:
a) is designed and constructed to function effectively
during and immediately after the recommended
flood level event; and
b) has direct access to low hazard evacuation routes
or an emergency rescue area above the PMF; if it is
for emergency services (including emergency
shelters, police facilities, hospitals and associated
facilities).
Earthworks
PO10 AO10 AO10 – Not Applicable
See the original
The page text is free to read. Viewing or downloading an original file needs an account.