8. Ensure each unit complies with outcomes of the Visitor Accommodation
Code AO23.2 which relates to private open space.
The Acceptable Outcomes seek for a minimum of 6m2 of private open space with a
dimension of 2m. The smallest balcony is unit 2-01B, which is 3.5m wide and 16m2 in size.
All other units have been substantially amended to provide for good sub-tropical design
elements, which include open courtyards at the front and rear of the living spaces to
promote air flow. This is compliant with the Sustainable Building Works Code, which seek
to reduce the reliance on air conditioning units through the apartment design, as well as
promoting indoor / outdoor living.
9. The proposed hydrant and pump to Thomas Street appears to be
excessively large and presents a poor outcome to the street. Provide
further justification for the size of the structure and further details to
make it less obtrusive to the street.
The design changes have allowed for more landscaping to the frontages and a revised
basement layout to incorporate services. The main hydrant booster has been relocated
to Albert St with no services presenting to Gympie Tce and Thomas St.
Figure. 4 – Services, Basement Plans with main services elements highlighted and
perspective from Albert St showing integrated hydrant booster.
Page 4 of
12
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Response to Information Request - MCU24-0074.pdfRelated documentApplication case desk ↗
About this file
- File size
- 5.9 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.