                                     Makepeace Island

                                     Assessment of Existing
                                     Wastewater
                  Our Ref:           Infrastructure –
                   4225              Proposed Change of
                                     Use

                                     Makepeace Island,
                                     Noosa North Shore
                                     Client:    Makepeace Island (Operations)
                                     Pty Ltd




                       Future-Plus Environmental Sunshine Coast (SQ)
                                 PO Box 1250 Buddina QLD

                         Future-Plus Environmental Gladstone (CQ)
                             PO Box 1290 South Gladstone QLD




p: 07 5450 2688           e: [email protected]                     PO Box 1250, Buddina Q 4575
f: 07 5450 2686           www.future-plus.com.au                         ABN 23 658 506 336
Full text of the other 7 pages

Page 2

             8th April 2013
                                                                               Our Ref: 4225-130402-1.0



             The Chef Executive Officer                      CC:     General Manager
             Sunshine Coast Regional Council                         Makepeace Island (Operations) Pty Ltd
             Sunshine Coast Mail Centre                              PO Box 672
             Locked Bag 72,                                          Tewantin Qld 4565
             QLD 4560

             Attention: Assessment Manager                           Attention: Nick Jones


                              SITE INVESTIGATION AND ASSESEMENT OF EXISTING
                                       WASTEWATER INFRASTRUCTURE
                                  MAKEPEACE ISLAND, NOOSA NORTH SHORE

             We refer to the above project and your request for the evaluation of the current
             on-site sewerage treatment plant and effluent irrigation area at Makepeace Island,
             Noosa North Shore.

             An assessment of the existing wastewater infrastructure currently servicing the
             accommodation facilities at Makepeace Island was undertaken by Future-Plus
             Environmental on the 2nd April 2013. The assessment of the on-site effluent
             disposal system was undertaken to determine its suitability to cater for the
             proposed change in use from non-publicly available accommodation to ‘letting of
             individual rooms of an existing detached house for short term visitor
             accommodation’. The number of rooms, guests and facilities remains relatively
             unchanged from the original assessment completed by Future-Plus Environmental
             (FPE) in 2007.

             This report summarises the findings of the site assessment, including an
             assessment of the hydraulic loading and effluent irrigation rate associated with the
             proposed change in use.


             Existing Infrastructure & Sizing

             The Makepeace Island accommodation facilities are currently serviced by a
             Department of Housing and Public Work (DHPW) approved, Advance Secondary
             Novaclear Aerated Waste Treatment System (AWTS) and an associated effluent
             disposal area.

             In accordance with the original Site and Soil Evaluation Report (ref no. 2771-02)
             completed by FPE on the 20th June 2007, the AWTS is to have a peak design
             capacity of not less than 2,475L/day (13 equivalent persons (EP)). Based on
             information supplied by the existing service agent (H2Gold), the AWTS currently


p: 07 5450 2688                         e: [email protected]                        PO Box 1250, Buddina Q 4575
f: 07 5450 2686                         www.future-plus.com.au                            ABN 23 658 506 336

Page 3

             has the peak design capacity of up to 2,700L/day (14 EP). This is considered to
             be satisfactory. Refer Photo Plate 1 contained in Attachment 1 of this
             correspondence showing the existing STP.

             Treated effluent is currently irrigated via a subsurface irrigation system within
             two (2) designated effluent disposal areas. The disposal areas were originally
             designed for 495m2 however a total area of 540m2 of raised garden beds was
             installed for conservative purposes. Refer Photo Plate 2 contained in Attachment
             1 of this correspondence showing the existing land application area.


             Wastewater Hydraulic Loading

             In accordance with the proposed change in use, the accommodation facilities
             located at Makepeace Island will have the capacity to cater for a total of twenty
             two (22) guests, located in a series of free standing buildings. In addition to the
             guest accommodation facilities, a total of two (2) staff members are
             accommodated within the caretaker’s residence.

             The hydraulic loading associated with the guest and staff accommodation
             facilities can be most reliably calculated using Chapter 5 Table A of DEHP
             (formerly DNR&M) Planning Guidelines for Water Supply and Sewerage, as
             follows:

             Table 1: Calculated Hydraulic Wastewater Flows from DEHP (formerly DNR&M)

                                                                         Daily Sewage
                                                        Rooms per                         Total Daily Sewage    Adopted Total
             Item           Source        Quantity                      Flow per Room
                                                         Structure                           Flow (L/day)        Flow (L/day)
                                                                            (L/day)

                  1       Bungalow(s)         3              2             300 – 6001         900 – 1 800            1,350

                  2       Long House          1              4             225 – 4502         900 – 1 800            900

                  3        Boat Shed          1              1             225 – 4502          225 – 450             225

                          Caretaker’s
                  4                           1              1             225 – 4502          225 – 450             225
                           Residence

                                                                                                Total (L/day)        2,700

                                                                 Total Site equivalent persons (EP) @ 200L/EP         14
             Note: 1Flow per person based on two (2) bedroom Apartment/Home Unit with reticulated water supply
                      2Flow per person based on one (1) bedroom Apartment/Home Unit with reticulated water supply



             Based on the above references, a total hydraulic loading of 2,700 litres per day
             (14EP) can be estimated for the guest and staff accommodation facilities at the
             Makepeace Island facility.


p: 07 5450 2688                                   e: [email protected]                                PO Box 1250, Buddina Q 4575
f: 07 5450 2686                                   www.future-plus.com.au                                    ABN 23 658 506 336

Page 4

             On-Site Wastewater Land Application Area

             Effluent irrigation currently occurs via subsurface dripper lines within the existing
             raised garden beds, totalling 540m2.

             Based on the estimated hydraulic loading of 2,700L/day, the required effluent
             irrigation area can be determined using Design Irrigation Rate (DIR) calculation
             as set out in Table M1 of AS1547:2012.

             Table 2: Minimum Required Irrigation Area

                                                      Irrigation Area as Determined by Table M1
                        AS1547:2000 Soil Category
                                                      of AS 1547
                           Soil Category 2 – Sand                      540m2


             From Table M1 of AS1547:2012 assuming a hydraulic loading of 2,700 litres per
             day and a Category 2 soil (DIR of 5mm/day), a minimum application area of
             540m2 is required. It is noted that there is sufficient space available to
             accommodate a 100% reserve area.

             It appears that the estimated hydraulic loading from the proposed change will not
             require a change in size of the existing effluent disposal system.


             Suitability of Existing Wastewater Treatment System and Land Application Area

             Based on the calculated peak hydraulic loading of 2,700L/day (14EP) and the
             minimum required land application area of 540m2, no change to the existing
             infrastructure in relation to sizing is considered necessary. The existing
             Novaclear AWTS and subsurface land application area appear to be in sound
             operating condition to accommodate the proposal.

             Provided the on-site sewerage facility is maintained in accordance with the
             recommendations provided in the Site and Soil Evaluation Report (ref no. 2771-
             02) and operation and maintenance manual, there will be minimal risk of impact
             to the site and surrounding areas. The system must be operated and maintained in
             compliance with the manufacturer’s requirements to ensure this risk is
             appropriately managed.




p: 07 5450 2688                         e: [email protected]                          PO Box 1250, Buddina Q 4575
f: 07 5450 2686                         www.future-plus.com.au                              ABN 23 658 506 336

Page 5

             We trust that the details set out above are of assistance. Please address all enquires
             to Michael Baynes of our office on 07 5450 2688.

             Yours faithfully
             FUTURE-PLUS ENVIRONMENTAL




             Paul Wood
             Director
             07 54502688




p: 07 5450 2688                       e: [email protected]                      PO Box 1250, Buddina Q 4575
f: 07 5450 2686                       www.future-plus.com.au                          ABN 23 658 506 336

Page 6

             Attachment 1
             Site Photos from Inspection 2nd April 2013




p: 07 5450 2688                        e: [email protected]   PO Box 1250, Buddina Q 4575
f: 07 5450 2686                        www.future-plus.com.au       ABN 23 658 506 336

Page 7

             Photo Plate 1: Existing Sewerage Treatment Plant




             Photo Plate 2: Existing Land Application Area No.1




p: 07 5450 2688                      e: [email protected]   PO Box 1250, Buddina Q 4575
f: 07 5450 2686                      www.future-plus.com.au       ABN 23 658 506 336

Page 8

             Photo Plate 3: Existing Land Application Area No.2




p: 07 5450 2688                      e: [email protected]   PO Box 1250, Buddina Q 4575
f: 07 5450 2686                      www.future-plus.com.au       ABN 23 658 506 336

Used in these records

About this file

File size
1.4 MB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Environmental Report (onsite effluent disposal).pdf · 1.4 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.