                                                                                Department of Housing and Public Works

                                                                                Form 15—Compliance certificate
                                                                                for building design or
                                                                                specification          Version 4 – July 2017


NOTE: This is to be used for the purposes of section 10 of the Building Act 1975 and/or section 46 of the
Building Regulation 2006.
RESTRICTION: A building certifier (class B) can only give a compliance certificate about whether building work
complies with the BCA or a provision of the Queensland Development Code (QDC). A building certifier (Class B)
can not give a certificate regarding QDC boundary clearance and site cover provisions.
1. Property description                              Street address (include no., street, suburb/locality and postcode)
This section need only be completed if details of
street address and property description are           216 David Low Way
applicable.
E.g. in the case of (standard/generic) pool              Peregian Beach                                                     Postcode 4573
design/shell manufacture and/or patio and
carport systems this section may not be              Lot and plan details (attach list if necessary)
applicable.
The description must identify all land the subject
                                                      Lot 73 P 93913
of the application.
The lot and plan details (e.g. SP/RP) are shown      In which local government area is the land situated?
on title documents or a rates notice.
                                                      Noosa Council
If the plan is not registered by title, provide
previous lot and plan details.

2. Description of                                        Proposed awning extension to an existing commercial building consisting
   component/s certified                                 of timber and steel awning framing hung from the existing framing with
Clearly describe the extent of work
covered by this certificate, e.g. all
                                                         CHS struts.
structural aspects of the steel roof                     Class of building / structure: Class 6, 10a
beams.
                                                         Items not certified:    Windows and Doors, Balustrading, Pool Fencing
                                                                                 Pre-fabricated Roof Trusses, Bracing & Girder Truss Support
                                                                                 Roof sheeting or Tiles, Wall and Floor Claddings//Finishes
3. Basis of certification                                AS 1170.1:2002     Dead and Live Loads and load Combinations
Detail the basis for giving the                          AS 1170.2:2011     Wind Actions
certificate and the extent to which
tests, specifications, rules,                            AS/NZS 1170.1:2002 Permanent, Imposed and Other Actions
standards, codes of practice and other                   AS 4055:2012       Wind Loads for Houses
publications, were relied upon.                          AS 4100:1998       Steel Structures
                                                         AS 1720:2010       Timber Structures
                                                         AS 1684.2:2010     Residential Timber Framed Construction
                                                         AS 2870:2011       Residential Slabs and Footings
                                                         AS 3700:2018       Masonry Structures
                                                         AS 3600:2018       Concrete Structures

                                                         Loading Criteria:
                                                         Wind Loading: Region: B         Terrain Cat: 2.5                   Topographic Class: T1
                                                         Shielding: PS                   Design Wind Classification: N3     Loading: 1.5 kPa

4. Reference documentation                               SCG Consulting Engineers Report & Drawing numbers:- 31124-N, S1.1 thru to S2.1
Clearly identify any relevant
documentation, e.g. numbered
structural engineering plans.

LOCAL GOVERNMENT USE ONLY
 Date received                                                                         Reference Number/s
Log in to download the original file

SCG 31124 F15.pdf · 236 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

Full text of the other 1 page

Page 2

5. Building certifier reference              Building certifier reference number
   number


6. Competent person details                  Name (in full)
A competent person for building work,
means a person who is assessed by             Sean Richardson
the building certifier for the work as       Company name (if applicable)                     Contact person
competent to practice in an aspect of
the building and specification design,        SCG Consulting Engineers                         Sean Richardson
of the building work because of the
individual’s skill, experience and           Phone no. (business hours) Mobile no.                      Fax no.
qualifications in the aspect. The             07 5455 5604                                               N/A
competent person must also be
registered or licensed under a law           Email address
applying in the State to practice the         [email protected]
aspect.
If no relevant law requires the
                                             Postal address
individual to be licensed or registered       PO Box 1661
to be able to give the help, the certifier
must assess the individual as having          Noosa Heads                                                Postcode 4567
appropriate experience, qualifications
or skills to be able to give the help.       Licence or registration number (if applicable)
If the chief executive issues any             RPEQ 5835
guidelines for assessing a competent
person, the building certifier must use
the guidelines when assessing the
person.
7. Signature of competent                    Signature                                              Date
   person                                                                                            24/06/2021
This certificate must be signed by the
individual assessed by the building
certifier as competent.



The Building Act 1975 is administered by the Department of Housing and Public Works

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.