Original source · versioned page text
Scg 31124 F15
Department of Housing and Public Works
Form 15—Compliance certificate
for building design or
specification Version 4 – July 2017
NOTE: This is to be used for the purposes of section 10 of the Building Act 1975 and/or section 46 of the
Building Regulation 2006.
RESTRICTION: A building certifier (class B) can only give a compliance certificate about whether building work
complies with the BCA or a provision of the Queensland Development Code (QDC). A building certifier (Class B)
can not give a certificate regarding QDC boundary clearance and site cover provisions.
1. Property description Street address (include no., street, suburb/locality and postcode)
This section need only be completed if details of
street address and property description are 216 David Low Way
applicable.
E.g. in the case of (standard/generic) pool Peregian Beach Postcode 4573
design/shell manufacture and/or patio and
carport systems this section may not be Lot and plan details (attach list if necessary)
applicable.
The description must identify all land the subject
Lot 73 P 93913
of the application.
The lot and plan details (e.g. SP/RP) are shown In which local government area is the land situated?
on title documents or a rates notice.
Noosa Council
If the plan is not registered by title, provide
previous lot and plan details.
2. Description of Proposed awning extension to an existing commercial building consisting
component/s certified of timber and steel awning framing hung from the existing framing with
Clearly describe the extent of work
covered by this certificate, e.g. all
CHS struts.
structural aspects of the steel roof Class of building / structure: Class 6, 10a
beams.
Items not certified: Windows and Doors, Balustrading, Pool Fencing
Pre-fabricated Roof Trusses, Bracing & Girder Truss Support
Roof sheeting or Tiles, Wall and Floor Claddings//Finishes
3. Basis of certification AS 1170.1:2002 Dead and Live Loads and load Combinations
Detail the basis for giving the AS 1170.2:2011 Wind Actions
certificate and the extent to which
tests, specifications, rules, AS/NZS 1170.1:2002 Permanent, Imposed and Other Actions
standards, codes of practice and other AS 4055:2012 Wind Loads for Houses
publications, were relied upon. AS 4100:1998 Steel Structures
AS 1720:2010 Timber Structures
AS 1684.2:2010 Residential Timber Framed Construction
AS 2870:2011 Residential Slabs and Footings
AS 3700:2018 Masonry Structures
AS 3600:2018 Concrete Structures
Loading Criteria:
Wind Loading: Region: B Terrain Cat: 2.5 Topographic Class: T1
Shielding: PS Design Wind Classification: N3 Loading: 1.5 kPa
4. Reference documentation SCG Consulting Engineers Report & Drawing numbers:- 31124-N, S1.1 thru to S2.1
Clearly identify any relevant
documentation, e.g. numbered
structural engineering plans.
LOCAL GOVERNMENT USE ONLY
Date received Reference Number/s
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.
Full text of the other 1 page
Page 2
5. Building certifier reference Building certifier reference number
number
6. Competent person details Name (in full)
A competent person for building work,
means a person who is assessed by Sean Richardson
the building certifier for the work as Company name (if applicable) Contact person
competent to practice in an aspect of
the building and specification design, SCG Consulting Engineers Sean Richardson
of the building work because of the
individual’s skill, experience and Phone no. (business hours) Mobile no. Fax no.
qualifications in the aspect. The 07 5455 5604 N/A
competent person must also be
registered or licensed under a law Email address
applying in the State to practice the [email protected]
aspect.
If no relevant law requires the
Postal address
individual to be licensed or registered PO Box 1661
to be able to give the help, the certifier
must assess the individual as having Noosa Heads Postcode 4567
appropriate experience, qualifications
or skills to be able to give the help. Licence or registration number (if applicable)
If the chief executive issues any RPEQ 5835
guidelines for assessing a competent
person, the building certifier must use
the guidelines when assessing the
person.
7. Signature of competent Signature Date
person 24/06/2021
This certificate must be signed by the
individual assessed by the building
certifier as competent.
The Building Act 1975 is administered by the Department of Housing and Public Works