Original source · versioned page text
Medium Density Residential Code
Performance Outcomes Acceptable Outcomes
1. the court is located at least 60 metres
from the external wall of an existing or
approved dwelling on adjoining or
nearby premises (as measured from
the centre line of the court); and
2. the vertical illumination resulting from
direct, reflected or other incidental
light emanating from the site does not
exceed 8 lux when measured at any
point 1.5 metres outside the boundary
and at any level from ground level
upward; and
3. any floodlighting is restricted to the
types that give no upward component
of light were mounted horizontally (i.e.
a full cut off luminaire).
AO21.3
Complies:
Mechanical plant is-
Mechanical plant and equipment will be suitably
located to ensure that it does not adversely impact
1. located at least 2 metres from the side
adjoining premises or is visible from the street.
or rear property boundaries;
2. where located at ground level,
screened by fencing 1.5 metres in