REVISION
No. DATE DESCRIPTION ISS. BY
A R Y
R E L IMIN UCTION
STREET PERSPECTIVE
P OT F OR
N
C O NSTR
WELCH HOME EXTENSION/RENOVATION DRAWING REGISTER matt bradley designs
©MATT BRADLEY DESIGNS - ACN: 637 963 396 - ABN: 53 637 963 396
www.mattbradleydesigns.com.au - [email protected] - 0488 554 020
ALL DESIGN, CONSTRUCTION METHODS & MATERIALS TO BE IN ACCORDANCE WITH:
- THE BUILDING CODE OF AUSTRALIA (BCA);
CLASS 1A DWELLING - RENOVATION + EXTENSION NO. DRAWING NAME ISSUE LATEST REVISION DESCRIPTION DATE ISSUED - THE QUEENSLAND DEVELOPER CODE (QDC);
- BUILDING REGULATIONS;
- CURRENT ISSUES OF AUSTRALIAN STANDARDS & MANUFACTURER'S
SPECIFICATIONS & INSTALLATION DETAILS FOR MATERIALS USED.
DIMENSIONS ARE SUBJECT TO SITE MEASUREMENT & VERIFICATION.
DO NOT SCALE OFF THIS DRAWING. PLANS COPYRIGHT MATT BRADLEY DESIGNS PTY LTD
REAL PROPERTY DESCRIPTION: WD-01 COVER PAGE PROJECT ADDRESS
- PROPERTY ADDRESS: 24 LYREBIRD COURT, PEREGIAN BEACH, QLD 4573 WD-02 CONSTRUCTION LEGEND 24 LYREBIRD CT, PEREGIAN BEACH, QLD
- LOT PLAN: 164P93135
- SITE AREA: 1,438.57 sq.m.
WD-03 SITE PLAN 4573
WD-04 EXISTING / DEMO DECK DRAWING TITLE
WD-05 EXISTING / DEMO LAUNDRY COVER PAGE
WD-06 EXISTING / DEMO ROOF PLAN
NEW HOME AREAS WD-07 NEW DECK
LAUNDRY: 6.1m² WD-08 NEW LAUNDRY CLIENT
JAMES WELCH
NEW DECK: 6.5m² WD-09 NEW ROOF PLAN DRAWN
SPA: 4.0m2 WD-10 ELEVATIONS JC/KD
SCALE
As indicated@ A3
TOTAL: 23.1m² DATE
MEASURED TO OUTSIDE FACE OF WALL 2022-07-08
PROJECT NO.
2022058
DRAW ING NO.
WD-01 rev:
QBCC LICENCE: 15025395
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 9 pages
Page 2
STANDARD SPECIFICATIONS SHEET
BE ADVISED : SOME CLAUSES IN THIS SPECIFICATION MAY NOT BE RELEVANT TO THIS PROJECT. CHECK AGAINST BUILDER SPECIFICATIONS AND ENGINEERING DRAWINGS & SPECIFICATIONS.
REVISION
- WHERE NECESSARY REINFORCE BELOW AND OVER OPENINGS WITH GALVANISED WOVEN WIRE - PROVIDE 100mm COMPACTED LIMESTONE BASE TO DRIVEWAY TOPPED WITH 50mm CLEAN SAND
No. DATE DESCRIPTION ISS. BY
FABRIC 75mm WIDE IN CENTRE OF EACH LEAF OPENING EXTENDING ALUMINIUM OF 600mm BEYOND AND GRADE TO FALLS.
GENERAL SYMBOLS LEGEND THE OPENING. - UNLESS NOTED PAVING PATTERN IS TO CLIENTS DETAIL.
- UNLESS OTHERWISE SHOWN ON DRAWINGS EXTERNAL FACE WORK: 230x110x76mm WINDOW SILLS: - BRICK PAVERS SHALL BE:
SYMBOL DESCRIPTION SYMBOL DESCRIPTION 2c FACE BRICK SPLAYED SILLS. TRAFFICABLE AREAS: MIN. 65mm SOLID CLAY OR CONCRETE
PEDESTRIAN AREAS: MIN. 43mm SOLID CLAY OR CONCRETE
HC EXTERNAL HOSECOCK FW FLOOR WASTE 6.0 LINTELS
GAS GAS CONNECTION SK KITCHEN SINK 16.0 ENERGY EFFICIENCY
MAX SPAN LINTELS SIZE BEARING EACH END - INSULATION MUST FORM A CONTINUOUS BARRIER WITH CEILINGS, WALLS AND FLOORS BY
HW HOT WATER CONNECTION VB VANITY BASIN (mm) (VERT x HORIZ x THICK) (mm) ABUTTING OR OVERLAPPING ADJOINING INSULATION.
- INSULATION MUST NOT ADVERSELY AFFECT DOMESTIC SERVICES OR FITTINGS.
CW COLD WATER CONNECTION WC WC WASTE 900 75x10 150 - REFLECTIVE INSULATION IS TO BE PROVIDED WITH A MINIMUM 25mm AIRSPACE AND IS FITTED
1200 75x75x8 150 CLOSE TO OPENINGS SUCH AS WINDOWS/DOORS ETC. AND IS PROVIDED WITH ADEQUATE SUPPORT.
HC HOUSE CONNECTION LT LAUNDRY TUB 1500 90x90x8 150
- BULK INSULATION MUST MAINTAIN ITS POSITION, THICKNESS. ENSURE THAT CEILING INSULATION
IO INSPECTION OPENING STK PLUMBING STACK TO 1800 100x75x8 230 OVERLAPS UN-INSULATED WALLS.
2100 125x75x8 230 - CONSTRUCTION JOINTS, SUCH AS BETWEEN WALL AND FLOOR, ARE TO BE TIGHT FITTING OR
ORG OVERFLOW RELIEF GULLY FLOOR ABOVE / BELOW 2400 125x75x10 230 SEALED USING CAULKING OR JOINERY ITEMS SUCH AS SKIRTING OR CORNICES.
2500 100x100x8 230 - EXHAUST FANS ARE TO BE FITTED WITH A SELF CLOSING DAMPER.
YG YARD GULLY SH SHOWER 3000 150x90x10 230 - ROOF LIGHTS MUST BE SEALED WITH WEATHERPROOF SEALS.
DP DOWNPIPE LOCATION BA BATH - HEATED WATER PIPING MUST BE THERMALLY INSULATED AND PROTECTED AGAINST THE WEATHER
AND SUN.
7.0 CARPENTRY WORK - INTERNAL HEATED WATER PIPING TO HAVE AN R VALUE OF 0.2
- ENCLOSED ROOF SPACE TO HAVE AN R VALUE OF R3.5
1.0 GENERAL - ROOF AND CEILING FRAMING SHOULD COMPLY WITH AS 1684 LIGHT TIMBER FRAMING CODE. DRAW
- ALL DIMENSIONS SHALL BE CHECKED ON SITE PRIOR TO COMMENCEMENT OF ANY WORK STRAP FIRMLY OVER WALL PLATES AND SECURELY FIX TO TOP OF PLATE BY 2x30mm GALV.
- ALL MATERIALS SHALL COMPLY WITH RELEVANT CURRENT AUSTRALIAN STANDARDS AND CLOUTS/STRAP.
UNLESS OTHERWISE STATED ON THE PLANS SHALL BE NEW AND THE BEST OF THE THEIR
RESPECTIVE KIND AND SUITABLE FOR THEIR INTENDED PURPOSES. - REFER TO AS 1684 FOR ROOF FRAMING SIZES UNLESS SPECIFIED ON DRAWINGS. SUBTERRANEAN TERMITES:
- ALL WORKMANSHIP SHALL COMPLY WITH RELEVANT CURRENT AUSTRALIAN STANDARDS AND TO
- SUPPLY AND FIX ALL BULKHEADS & FALSE CEILINGS AS SHOWN ON THE DRAWINGS.
GOOD TRADE PRACTICES SUBTERRANEAN TERMITE PROTECTION TO BE IN
- ALL WORK SHALL BE IN ACCORDANCE WITH REQUIREMENTS OF THE RESPECTIVE AUTHORITY
HAVING JURISDICTION OVER THE WORKS. 8.0 ROOFING ACCORDANCE WITH AS 3660. KORDON PHYSICAL
- THE ARCHITECTURAL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH THE SPECIFICATION, - SELECTED ROOFING MATERIAL SHALL BE INSTALLED AND FIXED IN ACCORDANCE WITH TERMITE BARRIER TO PERIMETER AND ALL SLAB
SCHEDULES AND CONSULTANTS DRAWINGS THAT FORM PART OF THE CONSTRUCTION DOCUMENTS MANUFACTURERS SPECIFICATION AND RELEVANT BUILDING CODES.
- GUTTER, FASCIA, DOWNPIPES, FLASHING SHALL BE IN LONGEST POSSIBLE LENGTHS.
PROTRUSIONS / PENETRATIONS. 80MM MIN
REFERRED TO IN THE "BUILDING CONTRACT".
- DO NOT SCALE FROM DRAWINGS. NOTIFY OF ANY ERRORS OR OMISSIONS BEFORE PROCEEDING - ALLOW FOR ALL JOINTS AND JOINING MATERIALS, COLLARS, STRAPS & FASTENINGS NECESSARY TO EXPOSED SLAB FACE TO PERIMETER TO ACT AS
WITH ANY WORKS COMPLETE WORK. VISUAL DETECTION SYSTEM AGAINST TERMITE
- ENSURE THAT SUBSTRATES ARE SUITABLE FOR THE INTENDED SUBSEQUENT FINISHES. - ALLOW FOR ALL ROOF PENETRATIONS, ROOF COWLS, FLASHING, FLUMES THROUGH ROOF.
- FIX GUTTERS & FLASHING TO PERMIT THERMAL MOVEMENT IN THEIR FULL LENGTH. INFESTATION AS PER AS3660 AND ALL RELATED
COMMENCEMENT OF WORK ON THE SUBSTRATES IMPLIES ACCEPTANCE BY THE SUBCONTRACTOR OF
THE SUBSTRATES ON WHICH FINISHES ARE APPLIED. - SEAL BETWEEN OVERLAPPING FLASHING; FLASHING TURNED DOWN OVER BASE OR APRON CODES. ANY OTHER SYSTEM USED MUST BE A
- CONTRACTOR IS TO SUPPLY ALL EQUIPMENT NECESSARY FOR THE COMPLETION OF THE RESPECTIVE FLASHING; FLASHING OVER METAL ROOF; FLASHING OVER SECRET GUTTERS; AROUND ROOF CERTIFIED SYSTEM TO BCA REQUIREMENTS.
WORKS. PENETRATIONS ETC.
- CONTRACTOR IS RESPONSIBLE FOR THE PROGRESSIVE CLEAN UP DURING AND AFTER THE
COMPLETION OF RESPECTIVE WORKS. 9.0 WINDOWS/GLAZING
- UNLESS OTHERWISE STATED ON THE DRAWINGS WINDOW FRAMES SHALL BE ALUMINIUM
2.0 EARTHWORKS RESIDENTIAL OR COMMERCIAL IN SECTION WITH POWDERCOAT FINISH AS SELECTED BY OWNER. NEW CONSTRUCTION
- UNLESS OTHERWISE STATED, REMOVE TOPSOIL TO A MINIMUM DEPTH OF 200mm INCLUDING ALL - ALLOW FOR FLYSCREENS TO BE FITTED TO ALL WINDOWS.
ROOTS, AND OTHER MATTER, AND REQUIRED BY THE SOIL CONDITION AND/OR BUILDER. PROVIDE - ANGLED WINDOW UNITS SHALL BE FACTORY MADE AND FIXED AND DELIVERED ON SITE AS A
SUITABLE CLEAN FILL AND COMPACT IN LAYERS NOT GREATER THAN 300mm TO REDUCE LEVELS AS COMPLETE UNIT. - FOR HABITABLE ROOMS:
SHOWN. - WHERE RELEVANT WINDOWS ARE TO COMPLY WITH THE SPECIFICATIONS PROVIDED BY THE - TOTAL R VALUE MUST BE 2.8
- DO NOT EXCAVATE SERVICES TRENCHES WITHIN AN ANGLE OF 45 DEGREES DOWN FROM THE THERMAL PERFORMANCE ASSESSOR.
BOTTOM EDGE OF THE FOOTING. - CLEAR GLASS GENERALLY: OBSCURE GLASS TO BATHROOMS, REFER TO DRAWINGS.
- ALL RETAINING WALLS TO BE TREATED WITH "BITKOTE" WATERPROOFING AGENT. - WHERE GLASS BLOCKS HAVE BEEN NOMINATED, THEY SHALL BE IN FRAMES AND INSTALLED TO
MANUFACTURERS SPECIFICATIONS
3.0 CONCRETE
- ALL CONCRETE REINFORCEMENT AND FORMWORK SHALL BE TO STRUCTURAL ENGINEERS DETAILS, 10.0 JOINERY
RELEVANT BUILDING CODES AND STANDARDS. - ALL JOINERY SHALL BE OF HIGHEST QUALITY MATERIALS TO BEST TRADE PRACTICES AND HIGH
- THE FOOTING AND SLAB CONSTRUCTION IS TO COMPLY WITH AS 2870. QUALITY FINISH.
- PROVIDE A PROPRIETARY VAPOUR BARRIER WHICH CONSISTS OF HIGH IMPACT RESISTANT - EXTERNAL DOOR FRAMES SHALL BE: 110x40 DOUBLE REBATED FRAME WITH 130x40 WEATHERED
POLYTHENE FILM MIN 0.2mm THICK WHICH HAS BEEN PIGMENTED AND BRANDED BY THE THRESHOLD U.N.O.
MANUFACTURER. - SUPPLY AND BUILD IN TIMBER DOOR FRAMES TO EXTERNAL LOCATIONS AS SHOWN ON
ARCHITECTURAL DRAWINGS.
4.0 TERMITE PROTECTION
- PROVIDE ANTI-TERMITE TREATMENT UNDER THE BUILDING AREAS IN ACCORDANCE WITH AS 2057, AS 11.0 CEILINGS
3660.1 AND APPENDIX D, FOR RETICULATED SYSTEMS. - CEILINGS SHALL BE RECESSED EDGE, MINIMUM 8.0mm PLASTERGLASS OR GYPROCK.
- BUILDER SHALL PROVIDE "BIFLEX" OR SIMILAR APPROVED ANTI-TERMITE TREATMENT IN ACCORDANCE - FLUSH JOINTS, SCREW HEADS, AND OTHER BLEMISHES IN THE SHEETS USING APPROVED SYSTEMS
WITH RELEVANT AUSTRALIAN STANDARD CODES. TO PROVIDE FLUSH SMOOTH CONTINUOUS SURFACE.
- PROVIDE AND FIX ALL FLUSH STOP BEADS & CASING BEADS TO ALL CORNERS & EDGES.
5.0 BRICKWORK - PROVIDE ALL SELECTED MOLDINGS AND CORNICES TO ALL CEILINGS AS SHOWN ON THE
- BRICK WORK SHALL COMPLY WITH : AS A123 MASONRY CODE & AS 3700 MASONRY CODE. DRAWINGS.
- BRICK GAUGE 7 STANDARD COURSES = 600 m m . MORTAR FOR MASONRY CONSTRUCTION
- TIES SHALL BE 3.5mm DIAMETER GALVANIZED WIRE KINKED FOR AND BUILT IN EVERY 5TH COURSE AT 12.0 PLASTERING
APPROXIMATELY 900mm CENTRES, WITH ADDITIONAL TIES AT THE RATE OF 1 TIE/300mm HEIGHT OF - INTERNAL WALL FINISHES INCLUDING CUPBOARD, BIN & FRIDGE RECESSES ETC SHALL BE (OTHER
OPENINGS AND VERTICAL CONTROL JOINTS AND WITHIN 150mm OF OPENINGS. BUILD TIES INTO EACH THAN FACE FINISHES OR WHERE COVERED BY FEATURE MATERIALS) FLOAT AND SET IN HARDWALL
LEAF AT LEAST 50mm. PLASTER U.N.O.
- VERTICAL CONTROL JOINTS SHALL BE 12mm WIDE FILLED AT COMPLETION WITH A CONTINUOUS - PLASTERED WALLS SHALL BE NOMINAL 12mm THICK CONSISTING OF 1:1:9, CEMENT:LIME:SAND
FILLER STRIP.
- CAVITIES TO BE KEPT CLEAR OF MORTAR. PROVIDE CAVITY BOARDS. TEMPORARILY OMIT BRICKS TO
RENDER, AND FINISHED WITH NOMINALLY 3mm HARDWALL PLASTER.
- SUPPLY AND FIX EXTERNAL CORNER BEADS TO ALL EXTERNAL CORNERS. matt bradley designs
©MATT BRADLEY DESIGNS - ACN: 637 963 396 - ABN: 53 637 963 396
PERMIT RAKING OUT OF CAVITY BOTTOMS. - PROVIDE STOP BEADS WHERE PLASTER WORK ABUTS TIMBER FRAMES, OR FACEWORK. www.mattbradleydesigns.com.au - [email protected] - 0488 554 020
- FORM WEEP HOLES EVERY FOURTH PERPEND ABOVE FLASHING AND CAVITY FILL KEEP CLEAR OF - EXTERNAL RENDER WHEN APPLICABLE SHALL BE 2 COAT SAND FINISH. (FOR PAINTING). ALL DESIGN, CONSTRUCTION METHODS & MATERIALS TO BE IN ACCORDANCE WITH:
- THE BUILDING CODE OF AUSTRALIA (BCA);
MORTAR. DO NOT LOCATE WEEPHOLES CLOSER THAN 500mm TO JOINTS IN DAMP PROOF COURSES - NIBS IN INTERNAL CORNERS ADJACENT TO DOOR FRAMES GREATER THAN 40mm SHALL NOT BE - THE QUEENSLAND DEVELOPER CODE (QDC);
- BUILDING REGULATIONS;
OR FLASHING. FLUSHED UP WITH FRAMES. - CURRENT ISSUES OF AUSTRALIAN STANDARDS & MANUFACTURER'S
SPECIFICATIONS & INSTALLATION DETAILS FOR MATERIALS USED.
- PROVIDE DAMP PROOF COURSES (DPC) IN THE BOTTOM 3 COURSES OF BRICK WORK AND SLAB - PROVIDE V-JOINTS IN RENDER & FINISHING PLASTER WHERE BRICK WORK ABUTS OR JOINS ONTO DIMENSIONS ARE SUBJECT TO SITE MEASUREMENT & VERIFICATION.
AND/OR FOOTINGS. DPC ADDITIVE SHALL BE CLEAR IN ALL FACEWORK. CONCRETE WORK. DO NOT SCALE OFF THIS DRAWING. PLANS COPYRIGHT MATT BRADLEY DESIGNS PTY LTD
- SETOUT BRICKWORK ACCURATELY, PLUMP, LEVEL AND PROPERLY BONDED. RISING WORK TO BE PROJECT ADDRESS
13.0 FLOORING FINISHES
RAKED BACK, JAMBS, REVEALS, CORNERS, PERPENDS, ETC TO BE TRUE, PLUMB AND IN LINE WITH
PERPENDS TRUE LINE. SETOUT DOOR FRAMES NEAR PERPENDICULAR WALL WITH A MERGIN OF 12mm - CARPET FLOOR COVERINGS TO NOMINATED AREAS COMPLETE WITH SELECTED UNDERLAY
24 LYREBIRD CT, PEREGIAN BEACH, QLD
OR GREATER THAN 50mm SMOOTH EDGE, DIMINISHING STRIPS ETC, TO COMPLETE THE WORKS: REFER TO DRAWINGS AND 4573
- PROVIDE 12mm PLASTERING MARGIN BETWEEN WINDOW FRAME AND INTERNAL BRICKWORK TO BE FINISHES SCHEDULE. DRAW ING TITLE
PLASTERED. - PROVIDE TILED FLOOR FINISHES TO NOMINATED AREAS COMPLETE WITH ALL MATERIALS, ANGLE
- WHERE NECESSARY REINFORCE BELOW AND OVER OPENINGS WITH GALVANISED WOVEN WIRE
FABRIC 75mm WIDE IN CENTRE OF EACH LEAF OPENING EXTENDING ALUMINIUM OF 600mm BEYOND
TRIMS ETC. TO COMPLETE THE WORKS: REFER TO DRAWINGS AND FINISHES SCHEDULE.
- PROVIDE TIMBER FLOOR FINISHES TO NOMINATED AREAS COMPLETE WITH ALL MATERIALS,
CONSTRUCTION LEGEND
THE OPENING. DIMINISHING BOARDS ETC TO COMPLETE THE WORKS: FLOOR BOARDS TO BE SANDED AND
POLISHED TO HIGH STANDARD WITH PREMIUM QUALITY SEALER (2 COATS). REFER TO DRAWINGS
BUILD IN ALCOR/PGI FLASHINGS AS FOLLOWS: AND FINISHES SCHEDULE.
CLIENT
- WHEREVER SHOWN ON DRAWINGS.
14.0 SIGNAGE
JAMES WELCH
- CAVITY WALLS BUILT OF SLAB ON GROUND (WHERE NOT PARGED).
- OVER LINTELS TO EXPOSED OPENINGS - EXTEND THE FULL WIDTH OF OUTER LEAF CONTINUOUS - WHERE NECESSARY SUPPLY & FIX SELECTED UNIT AND HOUSE NUMBERS TO EACH UNIT AND TO DRAWN
ACROSS CAVITY 50mm INTO INNER LEAF 2c ABOVE. LETTERBOXES AS SCHEDULED. JC/KD
SCALE
- OVER ROOF - EXTEND THE FULL WIDTH OF EXTERNAL LEAF, STEPPED TO ROOF SLOPE TURNED
DOWN MIN. 50mm OVER BASE FLASHING. TURN UP IN CAVITY SLOPING INWARDS AND BUILT INTO 15.0 PAVING
1 : 100 @ A3
INNER LEAF 1c ABOVE. - GENERALLY: WHEN PAVING IS INCLUDED IN THE BUILDING CONTRACT THE FOLLOWING SHALL DATE
- DOOR/WINDOW STILES - EXTEND THE FULL HEIGHT 150mm WIDE FIXED TO FRAMES INTERLEAVED APPLY AS A MINIMUM STANDARD. 2022-07-08
WITH SILL AND HEAD FLASHING AT EACH END. · SUPPLY AND LAY ALL PAVING TO EXTERNAL AREAS AS SHOWN ON WORKING DRAWINGS. PROJECT NO.
- STRUCTURE OR SERVICES WITHIN 30mm OF OUTER BRICK LEAF IN CAVITY: VERTICAL FLASHING · CUT, FILL & COMPACT SAND TO REQUIRED LEVELS. SCREED TO UNIFORM THINNESS AND LEVELS 2022058
CONTINUOUS 1c BELOW FL TO ABOVE STRUCTURE OR FRAME. NOMINAL 300m WIDE. · PROVIDE BRICK EDGE RETAINING FOOTING EMBEDDED IN MORTAR BENEATH THE PAVING BRICK DRAW ING NO.
- FOR HORIZONTAL STRUCTURES/SERVICES: CONTINUOUS FLASHING BUILT IN AS FOR OVER LINTELS.
- AT CAVITY WALLS WITH GLASS BLOCK 300mm WIDE FIXED TO GLASS BLOCK FRAME AND TURNED
· TO DRIVEWAY AREAS, PROVIDE NOMINAL 300x150mm CONCRETE FOOTING ALONG PERIMETER OF
DRIVEWAY AND BED EDGE BRICK IN MORTAR.
WD-02 rev:
AWAY IN CAVITY FROM INNER LEAF. QBCC LICENCE: 15025395
Page 3
NOTES:
- SETBACK RELAXATION LIKELY
REQUIRED FOR DECK
R Y NORTH
SITE NOTES: DA PROPOSED REVISION
OUN
B RENO / EXTENSION No. DATE DESCRIPTION ISS. BY
· UNLESS A SURVEY PLAN WAS R TY
PROVIDED ASSUME COUNCIL MAPPING PE
P RO
WAS USED. DISCLAIMER: COUNCIL
MAPPING MAY BE OFF AND WE WON'T
TAKE RESPONSIBILITY FOR INCORRECT
MAPPING. CLIENT TO PROVIDE SURVEY PR
PLAN FOR BUILDER TO CHECK. OP
· CONFIRM ALL DIMENSIONS ON SITE TO ER
TY
PR
EXISTING RESIDENCE PRIOR TO BO
OP
COMMENCEMENT OF ANY WORK. OX. EXISTING UN
APPR D
POOL AR
ER
· ALL BUILDING WORK TO BE CARRIED Y
TY
OUT IN ACCORDANCE WITH A.S.1684 AND WD-10
THE B.C.A. AND ALL OTHER RELEVANT
BO
CODES AND STANDARDS.
UN
EXISTING PRIMARY
· EXISTING PLUMBING AND ELECTRICAL 4
DA
DWELLING
WORKS TO BE REMOVED AND MADE
CT
RY
(NOT A PART OF THIS APPROVAL)
GOOD AS NECESSARY.
· THIS PLAN IS TO BE READ IN
D
PROPOSED
LYREBIR
CONJUNCTION WITH LANDSCAPING DECK EXTENSION + SPA
DETAIL PLANS FOR SPECIFIC PLANTING
LOCATIONS. PROPERTY BOUNDARY
· THE EXACT LOCATION OF
UNDERGROUND AND ABOVEGROUND PROPOSED
SERVICES SHALL BE PROVEN ON SITE.
2 LOCALITY PLAN RENO / EXTENSION
NO GUARANTEE IS GIVEN THAT ALL
EXISTING SERVICES ARE SHOWN. 1 : 500
· THIS DRAWING SET TO BE READ IN EXISTING SHEET APPROX. EXISTING
CONJUNCTION WITH THE SPECIFICATION APPROX. LOCATION METAL ROOF CROSSOVER
PROVIDED. OF EXISTING SHED
· BEWARE OF EXISTING SERVICES. WD-10
CONFIRM LOCATIONS PRIOR TO APPROX. EXISTING 3
00
APPROX. EXISTING
RETAINING WALL
CK
15
EXCAVATION. TAKE EXTREME CARE. DRIVEWAY
DE
· REFER ALL MAJOR WORKS TO RAMPS,
K
EC
WALKWAYS, DRIVEWAYS ETC
0
.D
50
(INCLUDING CARPARK WORKS, LEVELS & APPROX. EXISTING
OX
PR
DATUMS) REFER TO CIVIL ENGINEERS POOL PUMP
AP
DOCUMENTATION.
PR
· ALL EFFLUENT & WASTE WATER TO BE
EXISTING OP
CONNECTED TO COUNCIL SEWERAGE APPROX. L ER
TY
LINE AS PER COUNCIL & ESTATE POO BO
REQUIREMENTS U.N.O. UN
D AR
· ALL ROOF RAINWATER TO BE DIRECTED
Y
TO PROPERTY BOUNDARY FOR
DISTRIBUTION TO THE ROOF WATER
Y
HARVESTING SCHEME AS PER
REQUIREMENTS.
A R
IMIN UCTION
· CONTRACT DOCUMENTS AND
ENGINEERS DRAWINGS AND EXISTING
SPECIFICATIONS ARE TO TAKE
PRECEDENCE OVER THESE PLANS.
DEMOLITION NOTES:
PRIMARY
DWELLING
(NOT A PART OF THIS APPROVAL) R E L
P OT F OR C O NSTR
N
D CT
DARY
· CAP OFF EXISTING PLUMBING AND
ELECTRICAL WORKS AS NECESSARY BY
CERTIFIED TRADESPERSON.
matt bradley designs
TY BOUN
©MATT BRADLEY DESIGNS - ACN: 637 963 396 - ABN: 53 637 963 396
· MODIFIED BRICKWORK TO BE www.mattbradleydesigns.com.au - [email protected] - 0488 554 020
ALL DESIGN, CONSTRUCTION METHODS & MATERIALS TO BE IN ACCORDANCE WITH:
TOOTHED INTO EXISTING WHERE - THE BUILDING CODE OF AUSTRALIA (BCA);
- THE QUEENSLAND DEVELOPER CODE (QDC);
- BUILDING REGULATIONS;
APPLICABLE AND CAVITY TO REMAIN - CURRENT ISSUES OF AUSTRALIAN STANDARDS & MANUFACTURER'S
SPECIFICATIONS & INSTALLATION DETAILS FOR MATERIALS USED.
LYREBIR
CONTINUOUS AT ALL TIMES.
PROPER
DIMENSIONS ARE SUBJECT TO SITE MEASUREMENT & VERIFICATION.
DO NOT SCALE OFF THIS DRAWING. PLANS COPYRIGHT MATT BRADLEY DESIGNS PTY LTD
APPROX. FASCIA
· EXISTING MATERIALS TO BE REUSED WD-10 1 PROJECT ADDRESS
TO OWNERS DETAIL. 24 LYREBIRD CT, PEREGIAN BEACH, QLD
1000
· MATERIALS REMOVED FROM SITE 4573
MUST BE DISPOSED OF AS PER DRAW ING TITLE
COUNCIL REGULATIONS.
· INVESTIGATON SHOULD BE
PROPERTY BOUNDARY SITE PLAN
UNDERTAKEN BEFORE ALL WORKS
THAT REQUIRES EXCAVATION.
PROPOSED CLIENT
2 GARAGE EXTENSION APPROX. EXISTING JAMES WELCH
DRIVEWAY DRAWN
JC/KD
SCALE
WD-10 As indicated@ A3
APPROX. EXISTING DATE
2022-07-08
CROSSOVER
PROJECT NO.
2022058
0 1 2 4 6 8 10 20m
1 SITE
1 : 200
PLAN DRAW ING NO.
WD-03 rev:
QBCC LICENCE: 15025395
SCALE = 1:200
Page 4
APPROX. LOCATION OF
EXISTING SHED
APPROX LOCATION
OF EXISTING
SKIMMER BOX
NORTH
DEMOLITION LEGEND APPROX. EXISTING TREES
REVISION
No. DATE DESCRIPTION ISS. BY
SYMBOL DESCRIPTION
DEMOLISHED WALL
APPROX. EXISTING POOL SHED
DEMOLISHED TIMBER FLOOR/SUBFLOOR
DEMOLISHED 300 X 300 TILE
DEMOLISHED 600 X 600 TILE
DEMOLISHED TILE ROOF
DEMOLISHED SHEET METAL ROOF
660
PR
OP
APPROX. EXISTING POOL PUMP
ER
TY
DE 0
CK
50
BO
UN
D
660
AR
Y
RL 33680
APPROX. EXISTING RETAINING
APPROX. EXISTING
WALL
POOL
EXISTING
PRIMARY
DWELLING
(NOT A PART OF THIS APPROVAL)
A R Y
R E L IMIN UCTION
P OT F OR
N
C O NSTR
matt bradley designs
©MATT BRADLEY DESIGNS - ACN: 637 963 396 - ABN: 53 637 963 396
www.mattbradleydesigns.com.au - [email protected] - 0488 554 020
ALL DESIGN, CONSTRUCTION METHODS & MATERIALS TO BE IN ACCORDANCE WITH:
- THE BUILDING CODE OF AUSTRALIA (BCA);
- THE QUEENSLAND DEVELOPER CODE (QDC);
- BUILDING REGULATIONS;
- CURRENT ISSUES OF AUSTRALIAN STANDARDS & MANUFACTURER'S
SPECIFICATIONS & INSTALLATION DETAILS FOR MATERIALS USED.
DIMENSIONS ARE SUBJECT TO SITE MEASUREMENT & VERIFICATION.
DO NOT SCALE OFF THIS DRAWING. PLANS COPYRIGHT MATT BRADLEY DESIGNS PTY LTD
PROJECT ADDRESS
24 LYREBIRD CT, PEREGIAN BEACH, QLD
4573
DRAW ING TITLE
EXISTING / DEMO DECK
CLIENT
JAMES WELCH
DRAWN
PROPERTY BOUNDARY JC/KD
SCALE
1 : 100 @ A3
DATE
2022-07-08
PROJECT NO.
2022058
0 0.5 1 2 3 4 5 10m
1 EXISTING
1 : 100
/ DEMO DECK DRAW ING NO.
WD-04 rev:
QBCC LICENCE: 15025395
SCALE = 1:100
Page 5
NORTH
REVISION
NOTES: No. DATE DESCRIPTION ISS. BY
BUILDER TO VERIFY ALL DIMENSIONS
PRIOR TO ORDERING ANY MATERIALS
DEMOLITION LEGEND
SYMBOL DESCRIPTION
DEMOLISHED WALL PR
DEMOLISHED TIMBER FLOOR/SUBFLOOR
OP
ER
DEMOLISHED 300 X 300 TILE T YB
OU
DEMOLISHED 600 X 600 TILE ND
DEMOLISHED TILE ROOF
AR
Y
DEMOLISHED SHEET METAL ROOF
EXISTING
PRIMARY
DWELLING
(NOT A PART OF THIS APPROVAL)
100
REF.
GARAGE
A R Y
IMIN UCTION
DRYER ABOVE
BENCH
LAUNDRY
R E L
P OT F OR NSTR
APPROX. WALL
C O
APPROX. WALL
W/M
3730
N
2916
matt bradley designs
APPROX. WALL
©MATT BRADLEY DESIGNS - ACN: 637 963 396 - ABN: 53 637 963 396
www.mattbradleydesigns.com.au - [email protected] - 0488 554 020
1000
190
ALL DESIGN, CONSTRUCTION METHODS & MATERIALS TO BE IN ACCORDANCE WITH:
- THE BUILDING CODE OF AUSTRALIA (BCA);
- THE QUEENSLAND DEVELOPER CODE (QDC);
- BUILDING REGULATIONS;
- CURRENT ISSUES OF AUSTRALIAN STANDARDS & MANUFACTURER'S
SPECIFICATIONS & INSTALLATION DETAILS FOR MATERIALS USED.
DIMENSIONS ARE SUBJECT TO SITE MEASUREMENT & VERIFICATION.
DO NOT SCALE OFF THIS DRAWING. PLANS COPYRIGHT MATT BRADLEY DESIGNS PTY LTD
PROPERTY BOUNDARY PROJECT ADDRESS
EXISTING EXISTING BEAMS 24 LYREBIRD CT, PEREGIAN BEACH, QLD
DOWNPIPES ABOVE 4573
DRAW ING TITLE
1600 260 7210 EXISTING / DEMO LAUNDRY
END OF SLAB
CLIENT
JAMES WELCH
DRAWN
JC/KD
SCALE
1 : 100 @ A3
DATE
2022-07-08
PROJECT NO.
2022058
0 0.5 1 2 3 4 5 10m
1 EXISTING
1 : 100
/ DEMO LAUNDRY DRAW ING NO.
WD-05 rev:
QBCC LICENCE: 15025395
SCALE = 1:100
Page 6
NORTH
REVISION
NOTES: No. DATE DESCRIPTION ISS. BY
BUILDER TO VERIFY ALL DIMENSIONS
PRIOR TO ORDERING ANY MATERIALS
DEMOLITION LEGEND
SYMBOL DESCRIPTION
DEMOLISHED WALL
DEMOLISHED TIMBER FLOOR/SUBFLOOR
DEMOLISHED 300 X 300 TILE
DEMOLISHED 600 X 600 TILE
DEMOLISHED TILE ROOF
DEMOLISHED SHEET METAL ROOF
EXISTING PRIMARY
DWELLING
(NOT A PART OF THIS APPROVAL)
DARY
Y BOUN
T
PROPER
APPROX. WALL
SHEET METAL
APPROX. WALL
EXISTING
5082
APPROX. WALL
ROOF
1946
APPROX. WALL
2.5 °
3730
2916
APPROX. FASCIA
981
PROPERTY BOUNDARY
A R Y
IMIN UCTION
260 7210 260
PARAPET PARAPET
R E L
P OT F OR C O NSTR
N
matt bradley designs
©MATT BRADLEY DESIGNS - ACN: 637 963 396 - ABN: 53 637 963 396
www.mattbradleydesigns.com.au - [email protected] - 0488 554 020
ALL DESIGN, CONSTRUCTION METHODS & MATERIALS TO BE IN ACCORDANCE WITH:
- THE BUILDING CODE OF AUSTRALIA (BCA);
- THE QUEENSLAND DEVELOPER CODE (QDC);
- BUILDING REGULATIONS;
- CURRENT ISSUES OF AUSTRALIAN STANDARDS & MANUFACTURER'S
SPECIFICATIONS & INSTALLATION DETAILS FOR MATERIALS USED.
DIMENSIONS ARE SUBJECT TO SITE MEASUREMENT & VERIFICATION.
DO NOT SCALE OFF THIS DRAWING. PLANS COPYRIGHT MATT BRADLEY DESIGNS PTY LTD
PROJECT ADDRESS
24 LYREBIRD CT, PEREGIAN BEACH, QLD
4573
DRAW ING TITLE
EXISTING / DEMO ROOF PLAN
CLIENT
JAMES WELCH
DRAWN
JC/KD
SCALE
1 : 100 @ A3
DATE
2022-07-08
PROJECT NO.
2022058
0 0.5 1 2 3 4 5 10m
1 EXISTING
1 : 100
/ DEMO ROOF PLAN DRAW ING NO.
WD-06 rev:
QBCC LICENCE: 15025395
SCALE = 1:100
Page 7
NORTH
NOTES: REVISION
No. DATE DESCRIPTION ISS. BY
REFER ENGINEERS DRAWINGS
& SPECIFICATIONS FOR ALL
STRUCTURAL DETAILS, 6180
FRAMING, BRACING, TIE DOWN
AND SLAB/FOOTING DETAILS 1180
490
2000
BUILDER TO VERIFY ALL 2510 SPA
DIMENSIONS ON SITE PRIOR TO 3265
ORDERING MATERIALS
BATTENS TO
SEAL WET AREAS IN MATCH IMAGE
ACCORDANCE WITH AS3740 &
BCA REQUIREMENTS UNIVERSAL STEEL BEAMS
APPROX. LOCATION OF
PROVIDE FLOOR WASTE TO ALL EXISTING SHED
WET AREAS
SMOKE ALARMS TO BE FITTED APPROX. EXISTING
TREES
75
IN ACCORDANCE WITH BCA
00
15
APPROX. EXISTING
STAIRS, HANDRAILS AND
2075
1600
RETAINING WALL
2000
515
BALUSTRADING TO BE
CONSTRUCTED IN
ACCORDANCE WITH BCA P3.9.2 RL 33680
400
BALISTRADE REQUIRED IF
AND ALL RELEVANT CODES AND FALL IS GREATER THAN 1m SPA . EXISTIN
G
APPROX
EQUIREMENTS POOL SH
ED
SUN BED
2300
0
APPROX. EXISTING POOL PUMP
50
LIFT OFF HINGES TO BE FITTED PR
TO WC DOORS AND ENCLOSED OP
APPROX LOCATION ER
SPACES WHERE REQUIRED IN OF EXISTING TY
SKIMMER BOX BO
ACCORDANCE BCA P3.8.3.3 UN
D
660
AR
ANY NEW WINDOWS TO WET RL 33680 Y
AREAS MAY BE REQUIRED TO
BE TOUGHENED SAFETY GLASS APPROX. EXISTING
PROVIDE MECHANICAL POOL
VENTILATION AND DIRECTLY
VENT TO THE OUTSIDE OF THE 660
BUILDING (E.G. USING DUCTING 1200
TO A SOFFIT VENT)
UPPER FLOOR: HARDIES
'SECURA' FLOORING TO TILED
Y
AREAS
EXISTING
A R
PRIMARY
DWELLING
R E L IMIN UCTION
(NOT A PART OF THIS APPROVAL) P OT F OR
N
C O NSTR
matt bradley designs
©MATT BRADLEY DESIGNS - ACN: 637 963 396 - ABN: 53 637 963 396
www.mattbradleydesigns.com.au - [email protected] - 0488 554 020
ALL DESIGN, CONSTRUCTION METHODS & MATERIALS TO BE IN ACCORDANCE WITH:
- THE BUILDING CODE OF AUSTRALIA (BCA);
- THE QUEENSLAND DEVELOPER CODE (QDC);
- BUILDING REGULATIONS;
- CURRENT ISSUES OF AUSTRALIAN STANDARDS & MANUFACTURER'S
SPECIFICATIONS & INSTALLATION DETAILS FOR MATERIALS USED.
DIMENSIONS ARE SUBJECT TO SITE MEASUREMENT & VERIFICATION.
DO NOT SCALE OFF THIS DRAWING. PLANS COPYRIGHT MATT BRADLEY DESIGNS PTY LTD
PROJECT ADDRESS
24 LYREBIRD CT, PEREGIAN BEACH, QLD
4573
DRAW ING TITLE
NEW DECK
NEW HOME AREAS CLIENT
LAUNDRY: 6.1m²
JAMES WELCH
DRAWN
NEW DECK: 6.5m² JC/KD
SPA: 4.0m2 SCALE
1 : 100 @ A3
DATE
TOTAL: 23.1m² 2022-07-08
MEASURED TO OUTSIDE FACE OF WALL PROJECT NO.
2022058
0 0.5 1 2 3 4 5 10m
1 NEW
1 : 100
DECK DRAW ING NO.
WD-07 rev:
QBCC LICENCE: 15025395
SCALE = 1:100
Page 8
NOTES:
RELOCATE CONDENSER
NORTH
NOTES: REVISION
No. DATE DESCRIPTION ISS. BY
REFER ENGINEERS DRAWINGS
& SPECIFICATIONS FOR ALL
STRUCTURAL DETAILS,
FRAMING, BRACING, TIE DOWN
AND SLAB/FOOTING DETAILS
BUILDER TO VERIFY ALL
DIMENSIONS ON SITE PRIOR TO
ORDERING MATERIALS
SEAL WET AREAS IN
ACCORDANCE WITH AS3740 &
BCA REQUIREMENTS
PROVIDE FLOOR WASTE TO ALL
WET AREAS
SMOKE ALARMS TO BE FITTED
IN ACCORDANCE WITH BCA
EXISTING
STAIRS, HANDRAILS AND PRIMARY
BALUSTRADING TO BE
CONSTRUCTED IN DWELLING
ACCORDANCE WITH BCA P3.9.2 (NOT A PART OF THIS APPROVAL)
AND ALL RELEVANT CODES AND
EQUIREMENTS
100
LIFT OFF HINGES TO BE FITTED
EXISTING
EXISTING BEAM
TO WC DOORS AND ENCLOSED
SPACES WHERE REQUIRED IN DOWNPIPES
ACCORDANCE BCA P3.8.3.3
3430
INDICATIVE GAS
ANY NEW WINDOWS TO WET BOTTLES
AREAS MAY BE REQUIRED TO
BE TOUGHENED SAFETY GLASS
REF. GARAGE
PROVIDE MECHANICAL
90
90
580
VENTILATION AND DIRECTLY STORAGE
VENT TO THE OUTSIDE OF THE
90
BUILDING (E.G. USING DUCTING
2110 FGW
2490
2670
TO A SOFFIT VENT) EXISTING BEAM
820
1820
UPPER FLOOR: HARDIES
STOR.
'SECURA' FLOORING TO TILED DRY W/M
Y
AREAS
1160 90
90
R
APPROX.
A
190
PROPERTY BOUNDARY
R E L IMIN UCTION
1600
END OF SLAB
460 1760
STEP DOWN
NEW CONCRETE SLAB
NEW BEAM ABOVE
P OT F OR
N
C O NSTR
matt bradley designs
©MATT BRADLEY DESIGNS - ACN: 637 963 396 - ABN: 53 637 963 396
630 www.mattbradleydesigns.com.au - [email protected] - 0488 554 020
90 90 1520 90 ALL DESIGN, CONSTRUCTION METHODS & MATERIALS TO BE IN ACCORDANCE WITH:
- THE BUILDING CODE OF AUSTRALIA (BCA);
- THE QUEENSLAND DEVELOPER CODE (QDC);
- BUILDING REGULATIONS;
- CURRENT ISSUES OF AUSTRALIAN STANDARDS & MANUFACTURER'S
SPECIFICATIONS & INSTALLATION DETAILS FOR MATERIALS USED.
DIMENSIONS ARE SUBJECT TO SITE MEASUREMENT & VERIFICATION.
DO NOT SCALE OFF THIS DRAWING. PLANS COPYRIGHT MATT BRADLEY DESIGNS PTY LTD
90 2240 90 PROJECT ADDRESS
24 LYREBIRD CT, PEREGIAN BEACH, QLD
2420 6310
4573
DRAW ING TITLE
NEW LAUNDRY
9000
NEW HOME AREAS MAX 9M WALL
CLIENT
LAUNDRY: 6.1m² JAMES WELCH
NEW DECK: 6.5m² DRAWN
SPA: 4.0m2
JC/KD
SCALE
1 : 100 @ A3
TOTAL: 23.1m² DATE
2022-07-08
MEASURED TO OUTSIDE FACE OF WALL
PROJECT NO.
2022058
0 0.5 1 2 3 4 5 10m
1 NEW
1 : 100
LAUNDRY DRAW ING NO.
WD-08 rev:
QBCC LICENCE: 15025395
SCALE = 1:100
Page 9
5000
00
NOTES: NORTH
15
REVISION
No. DATE DESCRIPTION ISS. BY
PLUMBER TO VERIFY ALL DETAILS
PRIOR TO COMMENCEMENT OF BATTENS TO MATCH
WORK /ORDERING IMAGE
2000
PLUMBER RESPONSIBLE TO
CONFIRM ROOFWATER
DISCHARGE SYSTEM WITH ESTATE
AS CONS AND TO ENSURE
CORRECT CONNECTION IS
ACCESSED AND SYSTEM USED
GUTTERS AND DOWNPIPES: PR
ENSURE THAT ALL GUTTERS, BOX
APPROX.
O PE
GUTTERS AND DOWNPIPES ARE EXISTING POOL
RT
DESIGNED AND INSTALLED IN Y BO
ACCORDANCE WITH THE NCC VOL UN
TWO PART 3.5.3. WITH A MAXMIUM DA
DISTANCE BETWEEN DOWNPIPES R Y
OF 12M.
ALL SERVICES TO BE HIDDEN
FORM VIEW AT STREET LEVEL
EXISTING PRIMARY
DWELLING
(NOT A PART OF THIS APPROVAL)
A R Y
DARY
E L IMIN UCTION
Y BOUN
R
P OT F OR C O NSTR
560
T
N
PROPER
15 °
5082 matt bradley designs
EXISTING
NEW APPROX. WALL
2020
©MATT BRADLEY DESIGNS - ACN: 637 963 396 - ABN: 53 637 963 396
METAL
SHEET
ROOF
www.mattbradleydesigns.com.au - [email protected] - 0488 554 020
2.5 °
SHEET ALL DESIGN, CONSTRUCTION METHODS & MATERIALS TO BE IN ACCORDANCE WITH:
- THE BUILDING CODE OF AUSTRALIA (BCA);
- THE QUEENSLAND DEVELOPER CODE (QDC);
METAL - BUILDING REGULATIONS;
APPROX. FASCIA
- CURRENT ISSUES OF AUSTRALIAN STANDARDS & MANUFACTURER'S
ROOF SPECIFICATIONS & INSTALLATION DETAILS FOR MATERIALS USED.
DIMENSIONS ARE SUBJECT TO SITE MEASUREMENT & VERIFICATION.
DO NOT SCALE OFF THIS DRAWING. PLANS COPYRIGHT MATT BRADLEY DESIGNS PTY LTD
PROJECT ADDRESS
1000
24 LYREBIRD CT, PEREGIAN BEACH, QLD
4573
DRAW ING TITLE
PROPERTY BOUNDARY NEW ROOF PLAN
TRUSS PITCH TO MEET PARAPET APPROX. APPROX. PITCH
TOP OF PARAPET HEIGHT = 3.1m (CONFIRM ON-SITE)
(TBC ON SITE) CLIENT
JAMES WELCH
DRAWN
1270 260 7210 260
JC/KD
SCALE
PARAPET PARAPET 1 : 100 @ A3
DATE
2022-07-08
PROJECT NO.
2022058
1 NEW ROOF PLAN
0 0.5 1 2 3 4 5 10m DRAW ING NO.
WD-09 rev:
1 : 100 QBCC LICENCE: 15025395
SCALE = 1:100
Page 10
REVISION
EXTERIOR MATERIAL & FINISHES No. DATE DESCRIPTION ISS. BY
SYMBOL DESCRIPTION FINISH COMMENTS
BRK01 EXISTING BRICK VENEER PT01 ROLL FINISH
WB01 NEW PAINTED WEATHERBOARD CLADDING PT02 ROLL FINISH
PT01 PAINT TBC PATCH & PAINT WHERE REQUIRED
NOTE: ALL CLADDING AND FIRE RATED WALL SYSTEMS MUST BE INSTALLED IN ACCORDANCE WITH
MANUF' SPEC. POSITION CLADDING SHEETS AS SHOWN IN ELEVATIONS AS ACCURATELY AS POSSIBLE
EXISTING PRIMARY DWELLING
(NOT A PART OF THIS APPROVAL)
BRK01 EXISTING PRIMARY DWELLING
(NOT A PART OF THIS APPROVAL)
ROOF ROOF
LEVEL RL 38500 LEVEL RL 38500
WB01 WB01 WB01 BRK01 BRK01
FRONT
ENTRY
FIRST FIRST
LEVEL RL 36000 LEVEL RL 36000
1 NORTH ELEVATION 2 WEST ELEVATION
Y
1 : 100 1 : 100
A R
FIRST
LEVEL RL 36000
FIRST
LEVEL RL 36000
R E L IMIN UCTION
UNIVERSAL BEAM
VB01
UNIVERSAL BEAM
BATTENS TO MATCH IMAGE
P OT F OR
N
C O NSTR
GROUND GROUND
matt bradley designs
POOL SPA SPA ©MATT BRADLEY DESIGNS - ACN: 637 963 396 - ABN: 53 637 963 396
www.mattbradleydesigns.com.au - [email protected] - 0488 554 020
LEVEL RL 33680 LEVEL RL 33680 ALL DESIGN, CONSTRUCTION METHODS & MATERIALS TO BE IN ACCORDANCE WITH:
- THE BUILDING CODE OF AUSTRALIA (BCA);
- THE QUEENSLAND DEVELOPER CODE (QDC);
- BUILDING REGULATIONS;
- CURRENT ISSUES OF AUSTRALIAN STANDARDS & MANUFACTURER'S
SPECIFICATIONS & INSTALLATION DETAILS FOR MATERIALS USED.
DIMENSIONS ARE SUBJECT TO SITE MEASUREMENT & VERIFICATION.
DO NOT SCALE OFF THIS DRAWING. PLANS COPYRIGHT MATT BRADLEY DESIGNS PTY LTD
PROJECT ADDRESS
24 LYREBIRD CT, PEREGIAN BEACH, QLD
4573
DRAW ING TITLE
ELEVATIONS
3 SOUTH
1 : 100
ELEVATION 4 EAST
1 : 100
ELEVATION
CLIENT
JAMES WELCH
DRAWN
JC/KD
SCALE
1 : 100 @ A3
DATE
2022-07-08
PROJECT NO.
2022058
DRAW ING NO.
WD-10 rev:
QBCC LICENCE: 15025395
Used in these records
Revised Plans 12.09.pdfRelated documentApplication case desk ↗
About this file
- File size
- 1.9 MB (small file)
- File type
No other editions are linked here.