Attachment C - Pure building approval's letter · MCU21/0228.02

of 3

Text shows just the words. Original shows the document exactly as it was published.

                                                             Address: PO Box 1632 Buderim QLD 4556
                                                             Email: [email protected]
                                                             Phone: 07 5451 0579
                                                             ABN: 46 326 883 383




6/11/2024



Alex Rigby
Altum Property Group

Office 3, 245 David Low Way,
Peregian Beach, QLD 4573



Dear Alex

RE 245 David Low Way Peregian Beach - MCU21/0228.01

It’s my professional opinion that the space is not a habitable room as there is insufficient ceiling height.

Refer below,



P2.4.2 Room heights

A room or space must be of a height that does not unduly interfere with its intended function.



3.8.2.2 Height of rooms and other spaces

Heights of rooms and other spaces (see Figure 3.8.2.1) must be not less than—

(a)in a habitable room excluding a kitchen — 2.4 m; and

(b)in a kitchen — 2.1 m; and

(c)in a corridor, passageway or the like — 2.1 m; and

(d)in a bathroom, shower room, laundry, sanitary compartment, airlock, pantry, storeroom, garage, car
parking area or the like — 2.1 m; and

(e)in a room or space with a sloping ceiling or projections below the ceiling line within—

(i)a habitable room—
Full text of the other 2 pages

Page 2

                                                             Address: PO Box 1632 Buderim QLD 4556
                                                             Email: [email protected]
                                                             Phone: 07 5451 0579
                                                             ABN: 46 326 883 383


(A)in an attic — a height of not less than 2.2 m for at least two-thirds of the floor area of the room or
space; and

(B)in other rooms — a height of not less than 2.4 m over two-thirds of the floor area of the room or
space; and

(ii)a non-habitable room — a height of not less than 2.1 m for at least two-thirds of the floor area of the
room or space,

and when calculating the floor area of a room or space, any part that has a ceiling height of less than 1.5
m is not included.



The angled screen to the balcony provides ventilation, therefore cannot be considered as a room or an
enclosed space , as its not weatherproof.



P2.2.2 Weatherproofing

A roof and external wall (including openings around windows and doors) must prevent the penetration
of water that could cause—

(a)unhealthy or dangerous conditions, or loss of amenity for occupants; and




Kind Regards,


Stewart Magill

Suite 4 Suncoast Resort Business Centre, Surf Road Alexandra Headland QLD 4572
P.O. Box 1632 Buderim QLD 4556

P: 07 54510579 | M: 0434491447 | E: [email protected]

Page 3

Address: PO Box 1632 Buderim QLD 4556
Email: [email protected]
Phone: 07 5451 0579
ABN: 46 326 883 383

Used in these records

About this file

File size
233 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Attachment C - Pure building approval's letter.pdf · 233 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.