                                                         AO9.3
                                                         Buildings and structures meet the following minimum
                                                         setbacks to boundaries other than road frontages and
                                                         rear boundaries:
                                                              (a) 1.5 metre setback up to 4.5 metres height;
                                                              (b) 2 metres setback between 4.5 metres and 7.5
                                                                  metres height; and
                                                              (c) 2.5 metres if above 7.5 metres height.

                                                         AO9.4
                                                         Notwithstanding the provisions of AO9.2 and AO9.3, a
                                                         lesser building setback to:
                                                             (a) side and rear boundaries may apply for the
                                                                  following provided they comply with the
                                                                  Queensland Development Code:
                                                                       (i) open carport;
                                                                       (ii) swimming pool, garage/shed; and
                                                                       (iii) rainwater tank, retaining walls,
                                                                             screens and fences not exceeding
                                                                             2 metres in height; and
                                                             (b) front boundaries may apply for the following
                                                                  provided they comply with the Queensland
                                                                  Development Code:
                                                                        (i) swimming pool less than 1m above
                                                                              ground level; or
                                                                        (ii) decks or balconies less than 1m
                                                                              above ground level.

                                                         AO9.5
                                                         Buildings and structures on premises with frontage to
                                                         the Noosa River system are setback not less than 10
                                                         metres from the mean high water spring as shown in
                                                         Figure AP3-15A.

                                                         Alternative provision to the QDC.
Setback to a Watercourse in the Noosa Waters             AO10                                                     Not applicable.
Estate, Noosaville                                       For premises adjoining a watercourse within the
                                                         Noosa Waters estate no building work, filling or
PO10                                                     excavation works occurs within 4.5 metres from the
Land adjoining the revetment wall and for a width of     centre line of the top of the concrete revetment wall.
4.5 metres serves flood detention and amenity
functions, free of structures and impervious surfaces.   Editor's note—refer to Figure 6.3.1.5.
Log in to download the original file

Appendix E - Code Assessment.pdf · 495 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.