Log in to see the plans as drawn 01 02 03 04 05
5,180 4,000 6,335 3,075
HEIGHT PLANE
ROOF APEX ROOF APEX
RL 26.178 RL 26.178
ROOF02
884
884
PB01
SECONDARTY ROOF APEX SECONDARTY ROOF APEX
RL 25.294 RL 25.294
PB01
PB01
STUD
4,100
STUD
3,645
3,519
3,519
SITE BOUNDARY
SITE BOUNDARY
STUD
2,745
MASTER STAIR / VOID UPPER LIVING
PB01 PB01
TIMB10 TIMB10
UPPER FLOOR LEVEL UPPER FLOOR LEVEL
RL 21.775 RL 21.775
PB01 PB01
ENTRY / VOID / STAIR
LIVING GARAGE DRY COURT
3,110
3,110
PB01 PB01
TIL14 TIL14
GROUND FLOOR LEVEL GROUND FLOOR LEVEL
RL 18.665 RL 18.665
CON08 CON08
0 1 2 3 4 5
600
600
GARAGE LEVEL GARAGE LEVEL
RL 18.065 RL 18.065
1 SCALE
FILL
- 1:50
notes :
2 SECTION K 1 The designs, drawings and specification are copyright and always
- Scale 1:50
remain the property of Archend.
2 Before commencing construction:
- Verify all dimensions and levels.
- Verify location and levels of all services on site.
- Verify that floor levels and finished levels will enable connection to
services.
3 Do not scale this drawing. When in doubt refer to Designer.
issue amendment log by date
01 02 03 04 05 01 SECTION ISSUE FOR PRICING HC 18-07-22
02 PLANNING ASSESSMENT AS 30-08-22
5,180 4,000 6,335 3,075
03 PRICING SET MF 24/10/22
ROOF APEX ROOF02 ROOF APEX
RL 26.178 RL 26.178 04 PRICING ISSUE UPDATE AS 16-11-22
HEIGHT PLANE
884
884
05 RFI ISSUE MF 25-11-22
SECONDARTY ROOF APEX PB01 SECONDARTY ROOF APEX 06 COORDINATION ISSUE FOR APPROVAL AS 01-12-22
RL 25.294 RL 25.294
PB01
SITE BOUNDARY
SITE BOUNDARY
STUD
4,100
PB01
3,519
3,519
STUD
2,670
KITCHEN BRIDGE UPPER LIVING
TENDER ISSUE
NOT FOR CONSTRUCTION
TIMB10 TIMB10
CHECKED : .............................................
UPPER FLOOR LEVEL UPPER FLOOR LEVEL
RL 21.775 RL 21.775
PB01 PB01 PB01
ENTRY / VOID /
BATH01 GARAGE DRY COURT
STAIR
3,110
3,110
STUD
2,910
[email protected]
QLD. QBCC: 15226654
project:
TIL15 TIL14
'CASA DELLA ONDE'
GROUND FLOOR LEVEL GROUND FLOOR LEVEL
47 WAVECREST DR, CASTAWAYS
RL 18.665
CON08
RL 18.665 BEACH, 4567
600
600
client:
GARAGE LEVEL GARAGE LEVEL
RL 18.065 RL 18.065 JOHN & LINDA O'CONNOR
title:
FILL
SECTION K & L
north date: 01-12-22
3 SECTION L
- Scale 1:50 drawn: MF
checked: AH
scale @ A1 : 1:50
project D21-045_A
scale @ A3 : 1:100
drawing 05-06
sheet: A1
revison 06
GSPublisherVersion 645.0.99.0
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalVery large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.