Council archive · source document
Att 4 - Code Compliance · MCU17/0020
Attached to the e-mail Development application - Aquaculture MCU17/0020.
Column 1 Column 2 Column 3
Specific Outcomes Probable solutions Assessment
(if code
assessable)
impact upon other b) the infrastructure
premises; and has the capacity
d) ensure filling or to accept any
excavation does additional
not adversely loading;
impact upon other AND
premises by— S18.3 For Detached
i. causing ponding houses and Multiple
on the site or housing—
nearby land;
where slab on ground
ii. increasing
construction is
flooding, which
used, filling does
adversely affects
not extend more
the safety or use
than 1m beyond
of any land
the building
upstream and
footprint,
downstream; and
measured from the
iii. adversely outer walls of the
affecting the flow building ; or
of water in any
overland flow the design consists of
path. a suspended floor
construction.
Sloping sites &
ridgelines S19.1 Buildings and N/A – The site is not a sloping site
O19 Development on associated access ways
sloping sites— are not constructed on
a) is responsive to the land with a slope greater
natural topography than 25% (1 in 4);
of the site and AND
minimises cut and S19.2 Buildings are of
fill; split level design that
b) does not visually step down the slope or
dominate the hill have suspended floor
slope or interrupt construction;
the skyline; AND
c) is integrated with S19.3 Cut or fill is less
the natural site than 1.2m in depth;
characteristics AND
including S19.4 The distance
vegetation; and between the ground and
d) for Multiple the lowest part of the
housing, takes the floor of the building does
form of small not exceed 3m to avoid
separate buildings; large under building
areas;
AND AND
S19.5 Buildings present
no more than 2 or 3
storeys at any one point.
N/A – The site is not a sloping site
S20.1 No solution
O20 On steep slopes or provided
ridgelines which are
visible from the major