Appendix D Engineering Site Servicing Report
APPENDIX D
Engineering Site Servicing Report
Prepared by:
Ferg & Roeds Pty Ltd
www.bennettandbennett.com.au 201312_Town Planning Application | March 2021
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.
Full text of the other 20 pages
Page 2
BUIDLING
COMMUNITY FOR
FUTURE
GENERATIONS
SITE SERVICING REPORT
9 Butler St, Tewantin
Reference No. 201102
Prepared for K. Courtney
24 February 2021
FERG & ROEDS REF. 201102
Page 3
Document Control
Document Control
Document: SITE SERVICING REPORT
File Location: D:\Projects\201102 9 Butler St, Tewantin
Project Name: 9 Butler St, Tewantin
Project Number: 201102
Revision Number: A
Revision History
APPROVED FOR
REVISION NO. DATE PREPARED BY REVIEWED BY
ISSUE BY
A 24 February 2021 Nathan Flanders A.K. Sani A.K. Sani
Issue Register
DISTRIBUTION LIST DATE ISSUED NUMBER OF COPIES
K. Courtney 24 February 2021 Email
Ferg & Roeds Company Details
Approved by: A.K. Sani
Address: 4 Misty Ln, Cooroibah 4565
Signature:
Tel: 0420 305 181
Email: [email protected]
The information within this document is and shall remain the property of:
• Ferg & Roeds Pty Ltd
• Kieran Courtney
SITE SERVICING REPORT Ferg & Roeds Ref. i
9 Butler St, Tewantin 201102
Prepared for K. Courtney 24 February 2021
Page 4
Important Notice Important Notice This report is confidential and is provided solely for the purposes of supporting the 9 Butler St, Tewantin development application to Noosa Shire Council. This report is provided pursuant to a Consultancy Agreement between Ferg & Roeds Pty Ltd and K. Courtney, under which Ferg & Roeds undertook to perform a specific and limited task for K. Courtney. This report is strictly limited to the matters stated in it and subject to the various assumptions, qualifications and limitations in it and does not apply by implication to other matters. Ferg & Roeds makes no representation that the scope, assumptions, qualifications and exclusions set out in this report will be suitable or sufficient for other purposes nor that the content of the report covers all matters which you may regard as material for your purposes. This report must be read as a whole.The executive summary is not a substitute for this. Any subsequent report must be read in conjunction with this report. The report supersedes all previous draft or interim reports, whether written or presented orally, before the date of this report. This report has not and will not be updated for events or transactions occurring after the date of the report or any other matters which might have a material effect on its contents or which come to light after the date of the report. Ferg & Roeds is not obliged to inform you of any such event, transaction or matter nor to update the report for anything that occurs, or of which Ferg & Roeds becomes aware, after the date of this report. Unless expressly agreed otherwise in writing, Ferg & Roeds does not accept a duty of care or any other legal responsibility whatsoever in relation to this report, or any related enquiries, advice or other work, nor does FERG & ROEDS make any representation in connection with this report, to any person other than K. Courtney. Any other person who receives a draft or a copy of this report (or any part of it) or discusses it (or any part of it) or any related matter with Ferg & Roeds, does so on the basis that he or she acknowledges and accepts that he or she may not rely on this report nor on any related information or advice given by Ferg & Roeds for any purpose whatsoever. SITE SERVICING REPORT FERG & ROEDS Ref. ii 9 Butler St, Tewantin 201102 Prepared for K. Courtney 24 February 2021
Page 5
Table of Contents
Table of Contents
ABBREVIATIONS AND ACRONYMS ................................................................................... IV
1 INTRODUCTION ..........................................................................................................5
2 PROPOSED DEVELOPMENT.......................................................................................6
2.1 Development Scope ..................................................................................................................................... 6
2.2 Bulk Earthworks and Erosion and Sediment Control ................................................................................... 6
2.3 Access ........................................................................................................................................................... 6
2.4 Stormwater .................................................................................................................................................. 6
2.5 Sewerage ...................................................................................................................................................... 7
2.6 Water ........................................................................................................................................................... 7
2.7 Electricity ...................................................................................................................................................... 7
2.8 Telecommunications .................................................................................................................................... 7
3 SUMMARY ...................................................................................................................8
Appendices
ROL DEVELOPMENT LAYOUT
SITE CLASSIFICATION REPORT
List of Figures
Figure 1-1: Site Topography (Sourced from NSC Interactive Mapping)
SITE SERVICING REPORT FERG & ROEDS Ref. iii
9 Butler St, Tewantin 201102
Prepared for K. Courtney 24 February 2021
Page 6
ABBREVIATIONS AND ACRONYMS Abbreviations and Acronyms ABBREVIATION / ACRONYM DESCRIPTION AEP Average Exceedance Probability ARI Average Recurrence Intervals ASD Approach Sight Distance AS/NZS Australian Standard and New Zealand Standard Council Ipswich City Council CSD Crossing Sight Distance EMW Estate Major Works ESA Equivalent Standard Axels NSC Noosa Shire Council IPWEA Institute of Public Works Engineering Australia m Metres MGSD Minimum Gap Sight Distance PUP Public Utility Plant QUDM Queensland Urban Drainage Manual Q10 Flood event with ARI of 10 years Q100 Flood event with ARI of 100 years SISD Safe Intersection Sight Distance SSD Sight Stopping Distance DTMR Queensland Government Department of Transport and Main Roads SITE SERVICING REPORT FERG & ROEDS Ref. iv 9 Butler St, Tewantin 201102 Prepared for K. Courtney 24 February 2021
Page 7
Introduction 1 Introduction Kieran Courtney commissioned FERG & ROEDS to undertake a Site Servicing Report of the proposed residential subdivision of 9 Butler St, Tewantin (Lot 1 RP174646). This report has been prepared to address all engineering issues for Council to support a development application for a Reconfiguration of Lot (ROL) on the property. The site contains a dwelling located at the front of the property. The rear of the property is vegetated by trees and bushland. The block slopes towards the north western boundary as shown by the contours in Figure 1-1 below. Figure 1-1: Site Topography (Sourced from NSC Interactive Mapping) SITE SERVICING REPORT FERG & ROEDS Ref. 5 9 Butler St, Tewantin 201102 Prepared for K. Courtney 24 February 2021
Page 8
PROPOSED DEVELOPMENT
2 PROPOSED DEVELOPMENT
2.1 Development Scope
The proposed development will include the following:
• Reconfiguration of lot boundaries to create 2 new residential lots
• All lots shall be accessed via a Butler St
• All lots are proposed to be serviced with water, sewerage, electrical and NBN
• Lawful point of discharge
The proposed Stage 2 ROL development layout is provided in Appendix A.
2.2 Bulk Earthworks and Erosion and Sediment Control
Earthworks will not be required to be carried out as part of the works.
2.3 Access
All lots will be accessed directly from Butler Street. The proposed details are as follows:
• Utilise existing driveway crossovers:
o Provides access to lots and a second development connection to the external Butler Street.
o 60km/h Design speed utilised for sight distance checks.
o Adopting reaction time, RT of 2.0 seconds (urban environment) the required 123m SISD is achieved.
Further, access and egress into the proposed driveways could occur in the shoulder of the road,
away from the traffic lane, therefore minimising the risk of conflict.
• A widening of southern existing driveway crossover for lot 2:
o 4.2m wide access handle.
o 3.0m wide concrete driveway the length of the handle located centrally.
o Water, electrical and NBN conduits to be installed.
The proposed access design is represented on the engineering drawings provided in Appendix A.
2.4 Stormwater
A Dial Before You Dig Investigation has been completed for the site and its surrounding area. No existing stormwater
infrastructure was identified on the subject land. Runoff from the roof of the existing dwelling currently discharges
onto the ground and flows overland onto the downstream neighbouring property. It is proposed to discharge roof
water from the existing dwelling on Lot 1 to a new 3m3 soakage pit.
SITE SERVICING REPORT FERG & ROEDS Ref. 6
9 Butler St, Tewantin 201102
Prepared for K. Courtney 24 February 2021
Page 9
PROPOSED DEVELOPMENT A site classification report was undertaken in order to adequately determine the size required for the soakage pits promote groundwater infiltration and minimise the overland flow discharging onto the downstream neighbouring property during frequent rainfall events. The soakage pit will have a volume of 3m3. Runoff from Lot 2 will discharge into a second new 3m3 soakage pit. Each soakage pit is required to be located at least 3m from the property boundaries. The Queensland Urban Drainage Manual (QUDM 2017) classifies soakage pits as an acceptable method of discharging stormwater from a property (Level 1 drainage solution). The proposed soakage pits therefore constitute the lawful point of discharge for each lot. The proposed stormwater discharge solution is not expected to create an adverse impact to the downstream neighbouring property. In fact, it is envisaged to improve the current situation because the downpipes on the existing dwelling discharge straight onto the ground. The proposed stormwater network design is represented on the engineering drawings provided in Appendix A. 2.5 Sewerage There is currently a sewer main traversing the property. As part of the ROL, the house drain from the existing dwelling is to be disconnected from the current property connection as it would need to cross into Lot 2 and would become a combine drain. The existing dwelling on Lot 1 will be reconnected to a new property connection. The existing property connection will remain to service Lot 2. The proposed sewerage network design is represented on the engineering drawings provided in Appendix A. 2.6 Water There is an existing DN100 VC reticulation water main along the full extent of Butler Street on the opposite side of the road. There is also a DN300 AC trunk water main along the full extent of Butler Street fronting the property. The existing water meter for Lot 1 will be retained, and a new water meter and service will be provided for Lot 2. The closest fire hydrant is directly opposite the subject site on the reticulation main which will ensure the development meets all firefighting provision requirements. The proposed water design is represented on the engineering drawings provided in Appendix A. 2.7 Electricity Energex are the service authority responsible for planning and approval of electricity supply to service the development site. There is existing overhead electricity supply infrastructure along Butler St, which currently supplies the existing dwelling in Lot 1. It is proposed that this overhead supply will be utilised to provide connection for Lot 2. 2.8 Telecommunications The DBYD search identified that there is an existing Telstra cable bank on the western side of Butler Street and an existing NBN connection to the property. With the implementation and roll out of the National Broadband Network (NBN), the development site will be subject to application and formal Agreement with NBN Co. NBN compliant pit and pipe infrastructure will be designed and installed in conjunction with the electrical reticulation. Telecommunications infrastructure required for the proposed development will be designed by a suitably qualified telecommunications engineer during the detailed design phase. SITE SERVICING REPORT FERG & ROEDS Ref. 7 9 Butler St, Tewantin 201102 Prepared for K. Courtney 24 February 2021
Page 10
SUMMARY 3 SUMMARY This report has identified and addressed all engineering issues for Council to support a development application for a Reconfiguration of Lot (ROL) on the property. The report demonstrates that the two proposed lots can be serviced in accordance with Noosa Shire Council requirements. SITE SERVICING REPORT FERG & ROEDS Ref. 8 9 Butler St, Tewantin 201102 Prepared for K. Courtney 24 February 2021
Page 11
Appendix A ROL Development Layout
ROL Development Layout
SITE SERVICING REPORT FERG & ROEDS
9 Butler St, Tewantin Internal Ref.
Prepared for K. Courtney 201102
24 February 2021
Page 12
DIAL1100
BEFORE YOU DIG
LEGEND
EXISTING SEWER
EXISTING ABANDONED SEWER
EXISTING COMBINE DRAIN
EXISTING TELSTRA
EXISTING OPTIC FIBRE
EXISTING WATER
EXISTING STORMWATER
EXISTING FOUL WATER
EXISTING GAS
Y
TC
E
IC
LR
T
H
IO
N
/G
S
ITE
X
I
Y
TC
E
IC
LR
T
G
IU
N
/G
S
ITE
X
I
EXISTING KERB INVERT
EXISTING CONTOURS
DESIGN CONTOURS
PROPOSED KERB
PROPOSED ROAD ℄
PROPOSED DRIVEWAY
P
R
O
PO
S
T
S
E
R
DM
WA
E
T
R
PROPOSED SEWER
SEWER TO BE ABANDONED
PROPOSED WATER
PROPOSED RETAINING WALL
EXISTING STORMWATER
MANHOLE/PIT
PROPOSED STORMWATER
MANHOLE/PIT
EXISTING SPOT LEVEL
PROPOSED SPOT LEVEL
SITE LAYOUT
SCALE 1:200
PROPOSED
DRIVEWAY
DISCLAIMER
WHILST EVERY EFFORT HAS BEEN MADE TO ENSURE THAT THE
INFORMATION PROVIDED IN THIS DRAWING/DESIGN WAS ACCURATE AT
THE TIME IT WAS COMPILED, AS PART OF THE COUNCIL'S "AS
CONSTRUCTED" RECORDS, IT REMAINS THE RESPONSIBILITY OF
PROPERTY OWNERS AND THEIR CONTRACTORS, SUB-CONTRACTORS
EMPLOYEES, SERVANTS AND AGENTS AS APPROPRIATE IN THE
CIRCUMSTANCES TO MAKE ALL REASONABLE EFFORTS TO ASCERTAIN
THE PRECISE LOCATION OF EXISTING INFRASTRUCTURE INCLUDING
1x50ØELECTRICAL CONDUIT 1x50Ø TELECOM CONDUIT WATER MAINS, SEWERS AND DRAINS BEFORE UNDERTAKING
50Ø CONDUIT (WITH DRAW WIRES (WITH DRAW LINES EXCAVATION OR CONSTRUCTION WORK.
USERS OF THE INFORMATION SHOULD BE AWARE THAT SINCE THE
FOR 32Ø WATER INSTALLED) INSTALLED) ORIGINAL RECORDING OF THE DEPTHS IN RELATION TO GROUND
SERVICE MINIMUM SEPARATION TO MINIMUM SEPERATION TO LEVELS, CHANGES MAY HAVE OCCURRED AS A RESULT OF
ALL OTHER SERVICES SUBSEQUENT WORK OR ACTIVITIES INVOLVING FILLING OR
ALL OTHER SERVICES EXCAVATION. CONSEQUENTLY, DRW CONSULTING PTY LTD TAKES NO
RESPONSIBILITY FOR ANY APPARENT ERROR OR INACCURACIES THAT
ARE SHOWN TO EXIST AS AT THE DATE INFORMATION WAS PROVIDED
OR AT A LATER DATE. THE ABOVE ALSO APPLIES TO LOCATION AND
SOAKAGE PIT DETAIL DRIVEWAY TYPICAL SECTION DEPTH OF OTHER PUBLIC UTILITIES. ANY DAMAGE CAUSED TO
EXISTING PUBLIC UTILITIES BY THE CONTRACTOR WILL BE REPAIRED
SCALE 1:20 SCALE 1:20 BY THE RELEVANT AUTHORITY AT THE CONTRACTOR'S EXPENSE.
Scale @ A1
A.K. Sani
Project Leader
N.Flanders 1 : 200
© Ferg & Roeds Pty Ltd
ABN 14 632 264 790 9 Butler St, Tewantin
RPEQ 10697 All setting out should be carried out Designed Proposed Reconfiguration of Lot
0 2 4 8 These designs and drawings are the
in accordance with Council's N.Flanders
copyright of Ferg & Roeds Pty Ltd.
Noosa Shire Council
............................................ standard drawings or as nominated Drawn The drawing shall not be reproduced Servicing Plan, Sections & Details
on hard copy plans. Any digital N.Flanders or copied, in whole or part, without
information supplied by this office is Checked the written permission of Ferg &
Principal for information only. Any A.K. Sani Roeds Pty Ltd. Drawing No. 201102-SK01 Rev A
discrepancies should be discussed
K. Courtney
with the superintendent.
Authorised The contents of this drawing are Dev. App. No. N/A
9 Butler St A.K. Sani electronically generated, are Sheet No. 1 of 2
A Issue for Council Approval 24/02/21 NF/NF KS KS Tewantin QLD 4565 confidential and may only be used
Date
for the purpose they are intended. Issue for Approval
REVISION DATE DES/DFT WVR APP'D Feb. 2021
D:\Projects\200701 11 O'Leary Ave, Burpengary\CAD\200701-rev1.dwg Plotted by: ###### on 11/18/2020 11:09:57 AM
Page 13
DIAL1100
BEFORE YOU DIG
LEGEND
EXISTING SEWER
EXISTING ABANDONED SEWER
EXISTING COMBINE DRAIN
EXISTING TELSTRA
EXISTING OPTIC FIBRE
EXISTING WATER
EXISTING STORMWATER
EXISTING FOUL WATER
EXISTING GAS
Y
TC
E
IC
LR
T
H
IO
N
/G
S
ITE
X
I
Y
TC
E
IC
LR
T
G
IU
N
/G
S
ITE
X
I
EXISTING KERB INVERT
EXISTING CONTOURS
DESIGN CONTOURS
PROPOSED KERB
PROPOSED ROAD ℄
PROPOSED DRIVEWAY
12
12 P
R
O
PO
S
T
S
E
R
DM
WA
E
T
R
PROPOSED SEWER
SEWER TO BE ABANDONED
PROPOSED WATER
PROPOSED RETAINING WALL
EXISTING STORMWATER
MANHOLE/PIT
PROPOSED STORMWATER
MANHOLE/PIT
EXISTING SPOT LEVEL
PROPOSED SPOT LEVEL
SITE LAYOUT
SCALE 1:200
Scale @ A1
A.K. Sani
Project Leader
N.Flanders 1 : 200
© Ferg & Roeds Pty Ltd
ABN 14 632 264 790 9 Butler St, Tewantin
RPEQ 10697 All setting out should be carried out Designed Proposed Reconfiguration of Lot
0 2 4 8 These designs and drawings are the
in accordance with Council's N.Flanders
copyright of Ferg & Roeds Pty Ltd.
Noosa Shire Council
............................................ standard drawings or as nominated Drawn The drawing shall not be reproduced Driveway Sight Lines Plan
on hard copy plans. Any digital N.Flanders or copied, in whole or part, without
information supplied by this office is Checked the written permission of Ferg &
Principal for information only. Any A.K. Sani Roeds Pty Ltd. Drawing No. 201102-SK02 Rev A
discrepancies should be discussed
K. Courtney
with the superintendent.
Authorised The contents of this drawing are Dev. App. No. N/A
9 Butler St A.K. Sani electronically generated, are Sheet No. 2 of 2
A Issue for Council Approval 24/02/21 NF/NF KS KS Tewantin QLD 4565 confidential and may only be used
Date
for the purpose they are intended. Issue for Approval
REVISION DATE DES/DFT WVR APP'D Feb. 2021
D:\Projects\200701 11 O'Leary Ave, Burpengary\CAD\200701-rev1.dwg Plotted by: ###### on 11/18/2020 11:09:57 AM
Page 14
Appendix B Site Classification Report
Site Classification Report
SITE SERVICING REPORT FERG & ROEDS
9 Butler St, Tewantin Internal Ref.
Prepared for K. Courtney 201102
24 February 2021
Page 15
THE ONLY NAME IN SOILS
QBCC Licence No. 1018403
PH: 07 54 740 900
3/53 Gateway Drive, Noosaville 4566
Email: [email protected]
JOB NUMBER 21/0127 SITE CLASSIFICATION REPORT
CLIENT KIERAN COURTNEY.
SITE PROPOSED RESIDENCE.
LOCATION 9 BUTLER STREET, TEWANTIN.
REPORT DATE 12/02/2021
1. INTRODUCTION
The purpose of this report is to classify the subject allotment in accordance with Australian
Standard 2870 - 2011 'Residential Slabs and Footings'. From this classification, a footing
system can be recommended for the structure so as to allow adequate performance of the
footings under the soil conditions determined at the site.
The classification herein excludes the effect of trees on the site.
2. SITE DESCRIPTION
Type of Allotment Residential
Vegetation (Building Envelope) Sparsely grassed
Vegetation (Allotment) Grassed
Road Status Sealed
Slope Approximately Level
Surface Water will Drain Towards Surrounding Areas
Will Surface Water from adjoining No
allotments traverse this site?
Does the site have any watercourses No
Surrounding Allotments
Left Residence
Right Residence
Rear Bush
Depth to Weathered Rock N/a
Depth to Water Table N/a
3. SITE CLASSIFICATION AND TARGET STRATA
Based on the findings of the site investigation, the classification of the site is considered to
conform to:
CLASS “ P ” (Due to the poor bearing capacity - See Target
Stratum).
Please Note: If not for the poor bearing capacity encountered, this site has
the characteristics of an “ M” site.
in accordance with Australian Standard 2870 - 2011, 'Residential Slabs and Footings,
Construction'.
The Target Stratum for the foundation of the structure at location BH1 is the CLAYEY
SAND at a depth of 1400mm below existing ground level.
Page | 1 Borelogging in accordance with AS1726-2017 Geotechnical Site Investigations Code
21/0127
Page 16
The Target Stratum for the foundation of the structure at location BH2 is the CLAYEY
SAND at a depth of 1300mm below existing ground level.
It is the designing engineer’s responsibility to address the potential influence of any trees
present on or around the proposed building site.
If any further fill is placed over the existing ground, the structure shall be piered through
the fill into the existing material. Further note that the placement of reactive material as
fill or cutting of the site may change the site’s classification.
4. SOIL PROFILE
Refer to Soil Profile Report for borelog information.
Whilst every effort has been made to ensure that the borelogs carried out at the subject allotment
are indicative of the soil profile over the site any discrepancy between the profile detailed in
the borelogs and that observed during construction shall be referred to Global Testing for
immediate attention.
5. MATERIALS LABORATORY TEST RESULTS
Soil Laboratory testing carried out on samples of the soil taken from the site gave the following
results:
BOREHOLE BH2
DEPTH RANGE OF SAMPLE 1400-1700mm
LIQUID LIMIT (%) N/a
PLASTIC LIMIT (%) N/a
PLASTIC INDEX (%) N/a
LINEAR SHRINKAGE (%) N/a
INSTABILITY INDEX (%) N/a
SHRINK SWELL INDEX, Iss (%) 2.6
PREDICTED SURFACE MOVEMENT N/a
Please note that the Plasticity Index (PI) determined by the Atterberg Test may be correlated to
an Instability Index (Ips)with reference to the results of extensive testing carried out by others,
notably, Dr P Mitchell, ‘Footings for Small Scale Domestic Structures,’ March 1990.
Yours Sincerely,
MICHAEL PINKNEY. (Laboratory Manager)
Page | 2 Borelogging in accordance with AS1726-2017 Geotechnical Site Investigations Code
21/0127
Page 17
LIMITATIONS
Recommendations given in this report are based on the information supplied by the client
regarding the proposed building construction in conjunction with the findings of the
investigation. Any change in construction type, building location or omission in the client
supplied information, may require additional testing and/or make the recommendations
invalid.
The recommendations herein identify a target soil stratum into which the footings are to be
founded. The target stratum has been located by the depth in mm of the target stratum's upper
horizon boundary below the existing ground surface level at the time of the site investigation.
Any cutting or filling works and any surface erosion or deposits subsequent to the site
investigation, will alter the measured location of the stratum relative to the surface. Where
required, the author should be notified in such cases to confirm the location of the target
stratum.
The description of the soil given in the Soil Profile section of this report is intended as a brief
overview of the soil's primary constituents. For a detailed classification of the soil, the reader
should refer to the Soil Profile Reports and/or Borehole Reports attached to this report.
Every reasonable effort has been made to locate the test sites so that the borehole profiles are
representative of the soil conditions within the area investigated. The client should be made
aware however, that exploration is limited by time available and economic restraints. In some
cases, soil conditions can change dramatically over short distances, therefore, even careful
exploration programs may not locate all the variations.
If soil conditions different from those shown in this report are encountered or are inferred
from other sources, then the author must be notified immediately.
This report may not be reproduced except in full. The information and drawings provided
with this report shall only be used and will only be applicable for the development shown on
the client supplied information provided for this site.
Any dimensions, contours, slope directions and magnitudes shown on the Test Locality Plan
shall not be used for any building construction or costing calculations. The purpose of the
plan is to show approximate location of field tests only.
Any changes made to these recommendations by persons unauthorised by the author will
legally be interpreted as that person assuming the responsibility for the long-term
performance of the footing system.
The recommendations contained in this report have not taken into consideration the long-term
effects of any previous, current or potential subsurface work by mining companies or
potential slope instability problems. At the time of writing this report neither our client (nor
his agent) nor the local authority had made the author aware that these problems may be
affecting this allotment. If a mining subsidence or slope stability assessment is required for
this allotment, the recommendations of a suitably qualified geotechnical engineer should be
sought.
Page | 3 Borelogging in accordance with AS1726-2017 Geotechnical Site Investigations Code
21/0127
Page 18
THE ONLY NAME IN SOILS
SOIL PROFILE REPORT
CLIENT: Kieran Courtney. AUTHORISED Ferg & Roeds.
BY:
PROJECT: 9 Butler Street, DATE TESTED: 10/02/2021
Tewantin. JOB NO: 21/0127
Drilling Method: Jacro 105 100mm. Borehole
No.1
Depth Description PENET. Est. Bearing
(blows per 100mm)
(mm) Capacity
(kPa)
1 2 3 4
0 SILTY SAND (SM)-Fine to coarse, dark
grey, moist, loose.
100 2 50
200 2
300 1
400 2 50
500 1
600 2
700 1 30
800 2
900 CLAYEY SAND (SC)-Fine to coarse sand, 1
grey, medium plasticity fines, moist, loose.
1000 2 50
1100 2
1200 2
1300 2 50
1400 CLAYEY SAND (SC)-Fine to coarse sand, 8 >200
grey/ brown & pale brown, medium plasticity
fines, moist, medium-dense.
1500 8
1600 8 >200
1700
1800
1900
2000 Hole Terminated.
2100
2200
2300
2400
2500
Page | 4 Borelogging in accordance with AS1726-2017 Geotechnical Site Investigations Code
21/0127
Page 19
THE ONLY NAME IN SOILS
SOIL PROFILE REPORT
CLIENT: Kieran Courtney. AUTHORISED Ferg & Roeds.
BY:
PROJECT: 9 Butler Street, DATE TESTED: 10/02/2021
Tewantin. JOB NO: 21/0127
Drilling Method: Jacro 105 100mm. Borehole
No.2
Depth Description PENET. Est. Bearing
(blows per 100mm)
(mm) Capacity
(kPa)
1 2 3 4
0 (FILL) SILTY SAND (SM)-Fine to coarse,
dark grey, traces of gravel, moist, medium-
dense.
100 6
200 SILTY SAND (SM)-Fine to coarse, dark 6
grey, moist, loose.
300 2 50
400 1
500 CLAYEY SAND (SC)-Fine to coarse sand, 2
grey, medium plasticity fines, moist, loose.
600 1 30
700 2
800 2
900 1 30
1000 2
1100 1
1200 2 50
1300 CLAYEY SAND (SC)-Fine to coarse sand, 4 125
grey, medium plasticity fines, moist,
medium-dense.
1400 SANDY CLAY (CH)-High plasticity, red/ 6
brown, fine to coarse sand, moist, stiff.
1500 6
1600 5 150
1700
1800
1900
2000 Hole Terminated.
2100
2200
2300
2400
2500
Page | 5 Borelogging in accordance with AS1726-2017 Geotechnical Site Investigations Code
21/0127
Page 20
THE ONLY NAME IN SOILS
Site - 9 Butler Street,
Tewantin.
Page | 6 Borelogging in accordance with AS1726-2017 Geotechnical Site Investigations Code
21/0127
Page 21
The only name in soils
Test Locality Plan
LEGEND
N BH - Borehole Location
PN - Dynamic Cone Penetrometer Location
PT - Percolation Test
-Trees
Trees (see photo)
8m
BH1
PN1 4m
Approx.
Level 13m
BH2
PN2 1m
Not to Scale
Note: Any dimensions, contours, slope directions and magnitudes shown on the plan shall not be used for any building
construction or costing calculations. The purpose of the plan is to show the approximate location of the field tests only. All
dimensions in metres UNO .
Client: Kieran Courtney Job No. 21/0127
Address: 9 Butler Street, Date Tested: 10/02/2021
Tewantin. Authorised: Ferg and Roeds