Original source · versioned page text
Appendix D Engineering Site Servicing Report
DIAL1100
BEFORE YOU DIG
LEGEND
EXISTING SEWER
EXISTING ABANDONED SEWER
EXISTING COMBINE DRAIN
EXISTING TELSTRA
EXISTING OPTIC FIBRE
EXISTING WATER
EXISTING STORMWATER
EXISTING FOUL WATER
EXISTING GAS
Y
TC
E
IC
LR
T
H
IO
N
/G
S
ITE
X
I
Y
TC
E
IC
LR
T
G
IU
N
/G
S
ITE
X
I
EXISTING KERB INVERT
EXISTING CONTOURS
DESIGN CONTOURS
PROPOSED KERB
PROPOSED ROAD ℄
PROPOSED DRIVEWAY
P
R
O
PO
S
T
S
E
R
DM
WA
E
T
R
PROPOSED SEWER
SEWER TO BE ABANDONED
PROPOSED WATER
PROPOSED RETAINING WALL
EXISTING STORMWATER
MANHOLE/PIT
PROPOSED STORMWATER
MANHOLE/PIT
EXISTING SPOT LEVEL
PROPOSED SPOT LEVEL
SITE LAYOUT
SCALE 1:200
PROPOSED
DRIVEWAY
DISCLAIMER
WHILST EVERY EFFORT HAS BEEN MADE TO ENSURE THAT THE
INFORMATION PROVIDED IN THIS DRAWING/DESIGN WAS ACCURATE AT
THE TIME IT WAS COMPILED, AS PART OF THE COUNCIL'S "AS
CONSTRUCTED" RECORDS, IT REMAINS THE RESPONSIBILITY OF
PROPERTY OWNERS AND THEIR CONTRACTORS, SUB-CONTRACTORS
EMPLOYEES, SERVANTS AND AGENTS AS APPROPRIATE IN THE
CIRCUMSTANCES TO MAKE ALL REASONABLE EFFORTS TO ASCERTAIN
THE PRECISE LOCATION OF EXISTING INFRASTRUCTURE INCLUDING
1x50ØELECTRICAL CONDUIT 1x50Ø TELECOM CONDUIT WATER MAINS, SEWERS AND DRAINS BEFORE UNDERTAKING
50Ø CONDUIT (WITH DRAW WIRES (WITH DRAW LINES EXCAVATION OR CONSTRUCTION WORK.
USERS OF THE INFORMATION SHOULD BE AWARE THAT SINCE THE
FOR 32Ø WATER INSTALLED) INSTALLED) ORIGINAL RECORDING OF THE DEPTHS IN RELATION TO GROUND
SERVICE MINIMUM SEPARATION TO MINIMUM SEPERATION TO LEVELS, CHANGES MAY HAVE OCCURRED AS A RESULT OF
ALL OTHER SERVICES SUBSEQUENT WORK OR ACTIVITIES INVOLVING FILLING OR
ALL OTHER SERVICES EXCAVATION. CONSEQUENTLY, DRW CONSULTING PTY LTD TAKES NO
RESPONSIBILITY FOR ANY APPARENT ERROR OR INACCURACIES THAT
ARE SHOWN TO EXIST AS AT THE DATE INFORMATION WAS PROVIDED
OR AT A LATER DATE. THE ABOVE ALSO APPLIES TO LOCATION AND
SOAKAGE PIT DETAIL DRIVEWAY TYPICAL SECTION DEPTH OF OTHER PUBLIC UTILITIES. ANY DAMAGE CAUSED TO
EXISTING PUBLIC UTILITIES BY THE CONTRACTOR WILL BE REPAIRED
SCALE 1:20 SCALE 1:20 BY THE RELEVANT AUTHORITY AT THE CONTRACTOR'S EXPENSE.
Scale @ A1
A.K. Sani
Project Leader
N.Flanders 1 : 200
© Ferg & Roeds Pty Ltd
ABN 14 632 264 790 9 Butler St, Tewantin
RPEQ 10697 All setting out should be carried out Designed Proposed Reconfiguration of Lot
0 2 4 8 These designs and drawings are the
in accordance with Council's N.Flanders
copyright of Ferg & Roeds Pty Ltd.
Noosa Shire Council
............................................ standard drawings or as nominated Drawn The drawing shall not be reproduced Servicing Plan, Sections & Details
on hard copy plans. Any digital N.Flanders or copied, in whole or part, without
information supplied by this office is Checked the written permission of Ferg &
Principal for information only. Any A.K. Sani Roeds Pty Ltd. Drawing No. 201102-SK01 Rev A
discrepancies should be discussed
K. Courtney
with the superintendent.
Authorised The contents of this drawing are Dev. App. No. N/A
9 Butler St A.K. Sani electronically generated, are Sheet No. 1 of 2
A Issue for Council Approval 24/02/21 NF/NF KS KS Tewantin QLD 4565 confidential and may only be used
Date
for the purpose they are intended. Issue for Approval
REVISION DATE DES/DFT WVR APP'D Feb. 2021
D:\Projects\200701 11 O'Leary Ave, Burpengary\CAD\200701-rev1.dwg Plotted by: ###### on 11/18/2020 11:09:57 AM
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.