 Stockwell Development Group Pty Ltd                              SLR Ref No: 620.30735-R01-v1.2 Traffic Impact Statement 2023 03 30-
 Traffic Impact Statement                                                                                                update.docx
 Noosaville Childcare Centre                                                                                              March 2023
 Lot 4, Noosa Business Centre




4          Design Considerations
The design of internal car parking and circulation facilities has been reviewed against the relevant requirements
of Council’s planning scheme and/or the AS2890 suite of Australian Standards as summarised within Table 3.

Table 3      Design Compliance Assessment
 Design Component                                      Proposed Design                  Applicable Standard           Compliance
 Visitor parking space dimensions (User class 3)         2.6m x 5.4m                    Figure 2.2, AS2890.1                ✓
                                                    2.4m x 5.4m & 2.6m x
 Staff parking space dimensions (User class 1)                                          Figure 2.2, AS2890.1                ✓
                                                            5.4m
                                                   2.6m x 5.4m adjacent to a
 PWD parking space dimensions                                                           Figure 2.1, AS2890.6                ✓
                                                    2.4x x 5.4m shared area
 Parking aisle width                                         6.2m                       Figure 2.2, AS2890.1                ✓
 Blind aisle extension                                       1.4m                       Figure 2.3, AS2890.1                ✓

The results of the design compliance assessment presented in Table 3 confirms that the proposed design of the
off-street car parking area is in compliance with relevant design standards. Importantly, user class 3 has been
applied to determine the visitor parking spaces design on the following grounds:
     •     User class 3A is reserved for short term, high turnover parking that typically occurs all day, such as
           what’s experienced at shopping centres;
     •     User class 3 is reserved for short term parking such as what occurs at medical centres. This description
           better aligns with Childcare centre parking characteristics as there’s typically two peak parking periods
           during parents pick up/drop off and outside of these times, visitor parking demand remains relatively
           low.

Further to the above, a wider than required parking aisle under User class 3 is proposed to improve visitor
parking manoeuvrability and reduce periods of congestion.




                                                        Page 10

Used in these records

About this file

File size
10.8 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

RFI - Attachment 4 - Traffic Impact Statement.pdf · 10.8 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.