Skip to the record
Search everything, all in one place.

Original source · versioned page text

Appendix B - Code Assessment

of 42

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

Noosa Plan 2020: Amendment 3
Part 6 Zones \ 6.8 Other Zones Category \ 6.8.4 Rural Residential Zone Code




                                                           (b) 2.4 metres for a half court.
                                                           AO8.3
                                                           Courts are not lit; or
                                                           AO8.4
                                                           For lit courts:
                                                           (a) lighting structures are not more than 8 metres in
                                                                  height and set back at least 2 metres from any
                                                                  property boundary;
                                                           (b) the court is located at least 60 metres from the
                                                                  external wall of an existing or approved
                                                                  residential dwelling on an adjacent or nearby lot
                                                                  (as measured from the centre line of the court);
                                                           (c) the vertical illumination resulting from direct,
                                                                  reflected or other incidental lighting emanating
                                                                  from the site does not exceed 8 lux when
                                                                  measured at any point 1.5 metres outside the
                                                                  boundary and at any level from ground level
                                                                  upward; and
                                                           (d) lighting is hooded or baffled to direct lighting
                                                                  downward or is of a type that gives no upward
                                                                  component of light when mounted horizontally.
 PO9                                                     No acceptable outcome provided                               PO9 - Complies
 Development:                                                                                                         The proposal is supported by traffic engineering
 (a) does not compromise the safety, capacity or                                                                      advice which confirms that safe and practical access
      operation of the road network; and                                                                              can be provided to Black Mountain Range Road.
 (b) does not result in significant impacts on residents                                                              Proposed Lot 1 will obtain a new access to the west,
      close to rural roads.                                                                                           proposed Lot 2 will obtain a new access midway
                                                                                                                      along the lots frontage, proposed Lot 3 will retain the
                                                                                                                      existing residential access, and proposed Lots 4 and
                                                                                                                      5 will utilise a new dual access point. The Traffic
                                                                                                                      Engineering Letter confirms that the relevant sight
                                                                                                                      distance requirements can be achieved, subject to
                                                                                                                      vegetation management where identified, and that
                                                                                                                      the access arrangements are acceptable for the low
                                                                                                                      density rural residential use of the lots.
 Scenic amenity
                                                                                                                      AO10 - Complies.

Print Date: 23/03/2026                                                                                                                                                  Page 5
Log in to download the original file

Appendix B - Code Assessment.pdf · 608 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.