Log in to see the plans as drawn GENERAL NOTES
DO NOT SCALE PLANS, USE WRITTEN DIMENSIONS ONLY.
Brian Williams
THE OWNER/BUILDER SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS LEVELS,
SETBACKS AND SPECIFICATIONS PRIOR TO COMMENCING WORKS OR ORDERING
CONSTRUCTION NOTES MATERIALS AND SHALL BE RESPONSIBLE FOR ENSURING THAT ALL BUILDING WORKS
1. EXTERNAL WALLS = 90mm CONFORM TO THE BUILDING CODE OF AUSTRALIA . CURRENT STANDARDS, BUILDING REGULATIONS
2. INTERNAL WALLS = 90mm AND TOWN PLANNING REQUIREMENTS, REPORT ANY DISCREPANCIES TO THIS OFFICE.
2. N3 WIND DESIGN SPEED
3. ALL INTERNAL DOORS 204O HT ALL WORKS SHALL COMPLY WITH BUT NOT LIMITED TO THE
4. WC DOOR EXTERNAL REMOVABLE HINGES BUILDING CODE OF AUSTRALIA AND THE AUSTRALIAN STANDARDS.
THESE PLANS SHALL BE READ IN CONJUNCTION WITH ANY STRUCTURAL AND CIVIL
ALL SMOKE ALARMS MUST BE INTERCONNECTED ENGINEERING COMPUTIONS AND DRAWINGS
AS PER CLAUSE 3.7.2.2
LEGEND
CJ : CONSTRUCTION JOINT
DP : DOWNPIPE
FP : FIRE PLACE
15960
FW: FLOOR WASTE
EPS: EXPANDED POLYSTYRENE FOAM (EPS) Sandwiched 396 Lake Cooroibah
EQ EQ EQ EQ EQ EQ EQ
HWS: HOT WATER SYSTEM
AC: AIR CONDITIONING Rd, Cooroibah Qld
90 3600 2100 2400 1100 600 3600 90
PS: PLUMBING STACK / DUCT
SP: STEEL POST 980 90 2530 90
4565
T.B.C.: TO BE CONFIRMED -
RL: RELATIVE LEVEL ---
30
AHD: AUSTRALIAN HEIGHT DATUM
CSD: CAVITY SLIDING DOOR
OHC: OVER HEAD CUPBOARD AREAS
1500
1500
FG: FIXED GLASS
FSR: FLOOR SPACE RATIO
LIVING AREA: 139.2 m²
PORCH AREA: 1.9 m²
90
90 1500 90
90
LB: LOAD BEARING
900 1100 600
VERANDAH: 52.74 m²
D
PANTRY
NGL: NATURAL GROUND LINE
UBO: UNDER BENCH OVEN LD'Y KITCHEN TOTAL AREA: 193.84 m²
WO: WALL OVEN
3600
BED 2 BED 3
3970
4220
DW: DISHWASHER
BATH
MW: MICROWAVE
2630
WM: WASHING MACHINE F
90
WIR: WALK-IN-ROBE 90
90
ASD: SLIDING GLASS DOOR
530
DINING ROBE
8725
8545
530 530
ASW: ALUMINIUM SLIDING WINDOW ROBE
90
1070
900
10222
ADH: ALUM. DOUBLE HUNG WINDOW
90
13525
13525
ROBE
90
AAW: ALUM. AWNING WINDOW
90 450
LIN
ALW: ALUM. LOUVRE WINDOW No. Description Date
90
90
BCA :BUILDING CODE OF AUSTRALIA
4235
AS: AUSTRALIAN STANDARDS OFFICE
3245
3165
2705
BED 1 LIVING
ENS
90
90
90
90 1390 90
1500
1500
MECHANICAL VENTILATION IS TO BE
1800 20
DISCHARGED TO THE OUTSIDE AIR AND NOT
INTO THE ROOF UNLESS THE ROOF IS OPEN IN
1800
ACCORDANCE WITH CURRENT B.C.A
REQUIREMENT
EQ EQ EQ EQ EQ EQ EQ
6100 5900 980 2620
90 4510 90 1500 90 5900 90 3600 90 Managers Residence and office
2286 1994 3994 1994 3815 1917
6220
15960
6080 3660
FLOOR PLAN
ENERGY EFFICIENCY NOTES: Project number 141KR
1. ALL SHOWER ROSES TO BE 'AAA' SHOWER ROSES
2. IF WATER PRESSURE T0 BUILDING EXCEEDS 500 kpa. FLOOR PLAN Date 19/7/2021
17/07/2021 5:42:45 AM
PRESSURE LIMITING DEVICE TO BE INSTALLED.
3. MINIMW 4-STAR WELS RATED TOILETS TO BE INSTALLED.
1 1 : 100
BUILDER: TBA
4. MINIMW 3-STAR WELS RATED TAP'WARE FOR ALL W.C DOORS WITH A CLEARANCE LESS THAN QBCC NO: TBA
5. KITCHEN SINKS, BATHROOM BASINS & LAUNDRY TROUGHS. 1200mm FROM THE PAN TO BE READILY
REMOVABLE, SLIDING OR HINGED OUTWARDS IN
6. 250 LITRE RHEEM HOT WATER SYSTEM (OR SIMILAR)
7. MINIMUM 4-STAR MEPS RATED AIR CONDITIONERS TO BE INSTALLED (IF APPLICABLE) ACCORDANCE WITH PARTS 3.8.3.3 OF THE B.C.A A102
8. 80% TOTAL ENCLOSED FLOOR AREA TO HAVE ENERGY EFFICIENT GLOBES INSTALLED. 2015 VOL.2
9. INSULATION ABOVE 3.3 R VALUE TO ALL CEILING SPACE INCLUDING TERRACE & FRONT BALCONY Scale 1 : 100