BA250052 Architectural
Attached to the e-mail Generally in Accordance - Revised Design - MCU21/0150.02.
QUEENSLAND SMOKE ALARM
FAN & GPO SCHEDULE
REQUIREMENTS AS OF 1/1/17 SYMBOL ITEM
In Summary: TYPE FIXTURE DESCRIPTION SUPPLIER COUNT S
Smoke alarm devices must be installed: Smoke Alarm
Double GPO Double GPO: Clipsal Iconic POINT - DOUBLE GPO Electrician 10
* If practicable, on the ceiling - if the ceiling slopes, it must be in an area of the ceiling that is Double GPO Double GPO: Clipsal Iconic with USB POINT - DOUBLE GPO Electrician 2 MB or SB Meter Box or Subboard
between 500mm and 1500mm from the apex of the ceiling. Fan Fan: Ventair Spinaker 4 Blade - White Fan Electrician 4 GAS Gas Bottle - location
* If installing on the ceiling is not practicable, on an exposed joist or beam that when Single GPO Single GPO: Clipsal Iconic POINT - SINGLE GPO Electrician 4
measured from the ceiling does not have a depth of more than 300mm when measured TV Point TV Point: TV Point TV Point Electrician 1 DW Dishwasher
from the ceiling. Waterproof Double GPO Waterproof Double GPO: 300 POINT - DOUBLE GPO Electrician 1
HW Hotwater - Instantaneous gas
* If these two placements are not practicable, the device can be installed on a wall in an Down light - LED
area that is between 100mm and 300mm from the ceiling and more than 300mm from MECHANICAL EQUIPMENT SCHEDULE
the corner of 2 walls. Ceiling Fan
Item Description Model Supplier Count
D Data Point
Gas Connection point Bottle supplied and installed by others Owner 1
Smoke alarm devices must not be:
* within 300mm of a light fitting
Gas hot water unit Rheem 26L Gas Hot water 26L Owner 1 PH Phone Point
Smoke Alarms Smoke Alarms supplied and installed by Electrican Electrician Electrician 4
* if installed on a ceiling, within 300mm of a corner of the ceiling and wall TV TV Point
Ventair Airbus 250 with LED Ventair Airbus with LED PVPX250 + Electrician 1
* if installed in a stairwell, out of reach of smoke because of an obstruction ABGLED250WH.RD L Exhaust Fan & Light
* within 400mm of an opening from which air supplied from an air conditioner
or force air ventilation within 400mm of the blades of a ceiling fan Exhaust Fan
LIGHTING FIXTURE SCHEDULE
WM Exhaust Wall Mounted
FIXTURE DESCRIPTION Count
P Pendant Light
Downlight - Round - LED Rapid LED 8W Tri White - Daylight Globe 21
Grand total: 21 Double Power Point
Single Power Point
USB SPECIALTY EQUIPMENT SCHEDULE Water Proof Dble Power Point
WP
TYPE MODEL COUNT Spot light
Westinghouse 60cm gas cooktop WHG644SC 1
2W Westinghouse 60cm gas oven WVG6515SD 1 Double spotlight
Westinghouse 52cm concealed rangehood WRI515SC 1 Wall light light
WP VENT R/HOOD
A/C Airconditioner (Split system)
S S AB 2W Two way
DW
DUCT UBO UBO Under bench oven
R/H
C/T
EXHAUST
AB AB ANY ROOF/EAVE VENTS
MW Microwave Single GPO
AB TO BE COMPLIANT TO NOTE: SUPPLY & INSTALL TV ANTENNA
MW
USB BAL 19 REQUIREMENTS. RH Rangehood Single GPO
L LEAD IN POWER CONNECTION TO CT Cooktop
HW AND GAS EXISTING ON SITE POWER - SOLAR
SB
BOTTLES 56" NBN Broadband Connection
SUPPLIED
OFF GRID TO BE SUPPLIED BY CLIENT
BY OWNER S RC A/C Remote Control
NOTE: CEILING FANS TO BEDROOMS USB USB Point with GPO
HW AND PATIO - SIZES TO BE 52 INCH.
S CEILING FAN TO LIVING ROOM TO HTR Heated Towel Rail Hardwire
TV BE 56 INCH FOR ENERGY EFFICIENCY
Extension rod
REQUIREMENTS. POWERPOINT LOCATION HEIGHTS IN MM
Gas to ceiling fan
WALL SWITCHES 1100
2W CLIENT TO SUPPLY GAS HOTWATER
UNIT AND GAS SERVICES SUPPLY AND POWERPOINTS UNO 300
INSTALLATION.
ABOVE BENCH POWEROINTS 1100
UNDER BENCH POWERPOINTS 300
ELECTRICAL PLAN MICROWAVE POWERPOINTS
FRIDGE POWERPOINTS
1600
1600
SCALE 1:100 AB - ABOVE BENCH
RANGEHOOD 1800
FOR CONSTRUCTION UB - UNDER BENCH TV / DATA UNO 300
Rev No. Description Date
1 Concept Floor Plan 12/08/2024 Client: Sophie McLaren
ELECTRICAL PLAN
22/11/2024 12:13:24 PM
2 Concept Plans Selections 23/08/2024 Description: New Dwelling
3 Preliminary Working Drawings 28/08/2024 Project number 6335
4 For Construction 3/10/2024
5 For Construction - Lodgement 15/10/2024 Site Address: 9 Rules Rd Pomona Qld Date 12/08/2024 A110
6 For Construction - Contract 18/11/2024 Drawn by T.D
© QBCC Lic no. 15187645 Checked by T.D Scale As indicated