minimum formed width of 3.5m, and cleared width of 6m throughout, and wide enough to enable passing of vehicles at a maximum of 200m intervals. All accesses are to be all-weather access and constructed to a standard able to carry a medium rigid emergency vehicle, and with turn around areas at each cabin and the residence, and able to accommodate a turning area for fire-fighting appliances, in accordance with Qld Fire & Emergency Services (QFES) Fire Hydrant and Vehicle Access Guideline. With the above recommendations being met, the proposed development will be considered to be in compliance with the requirements and intent of the Natural Hazards Overlay Code. 3.5 Water Availability for Fire-Fighting Purposes The Noosa Plan 2017, Division 9 – Natural Hazards Overlays Code (O8) prescribes the proposed development is to provide ‘an adequate and accessible water supply for fire- fighting purposes’. The proposed development will not be on reticulated water, and is consequently deemed appropriate that each structure be serviced by a minimum 5,000L water tank, with male 50mm cam lock fittings (standard fire-fighting fittings). Tanks are to be located within 10m of each structure and with all-weather access within 6m of each tank. Consequently, with these recommendations being met, the proposed development is considered to be in compliance with the requirements and intent of the Natural Hazards Overlay Code. 4.0 Recommendations and Conclusions This report details the assessment of Bushfire Hazard and risk mitigation measures acting on the proposed development, with consideration to the requirements of: the Queensland State Government Single State Planning Policy - Part E (SPP 2017); the Bushfire Resilient Communities Technical Reference Guide (QFES,2019); the Australian Standard (AS 3959- 2018) - Construction of buildings in bushfire prone areas; and the Noosa Plan 2017, Division 9 – Natural Hazards Overlays Code. This assessment has confirmed vegetation posing a High Potential Bushfire Hazard to the proposed development is present to the northwest through west to southwest, and a medium potential hazard is present to the north (site) & adjacent site to the northeast, and to the south through southeast & northeast (Refer Section 2.2). These vegetation communities have the potential to carry high to moderate fuel loads and subsequently present a potential Bushfire Hazard to the proposed development. Vegetation to the north and east (central) of the site have been classified as having a Low Potential Bushfire Hazard. Subsequently, the proposed development location is considered to be within a potential impact buffer area. 13 March 2020 292 Illoura Place, Cooroibah - Bushfire Management Plan Page 19 www.wollemi-eco.com.au
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
292 Illoura Place Cooroibah - Bushfire Management Plan.pdfRelated documentApplication case desk ↗
About this file
- File size
- 1.2 MB (small file)
- File type
No other editions are linked here.