Original source · versioned page text
26.005_Shorehaven Dr_Issue A_02Apr26(1)
Attached to the e-mail Combined Application MCU26/0034 & OPW26/0056 - DA Form 1, Owners Consent, Civil Plans - 117 Shorehaven Drive Noosaville.
notes
1. Survey information to be confirmed by Licensed
Surveyor prior to construction. Where property
boundary locations are not clear, the contractor shall
organise an identification survey to locate required
boundaries .
2. Extent of site earthworks to be confirmed by
engineer &/or contractor on site prior to construction.
3. Contractor to confirm siting & orientation prior to
setout. Location of pontoon & pontoon setout to be
carried out by Licensed Surveyor.
to boundary corner
4. All services to be located on site by contractor prior
64 from screw
to construction.
Dimensions taked from screw boundary
Projected
placed in revetment wall 5. Do not scale off drawings, use figured dimensions
only. Any dimensions not nominated must be referred to
the Designer for confirmation. Contractor shall verify all
dimensions on site prior to construction.
property details
4500
No. 117 Shorehaven Drive
" 10000 from revetment wall
18°25'45
6000
Noosaville QLD 4566
) Noosa Shire Council
(40.831m
9500
Locality - Noosaville
canal
11000
Lot 683 on RP897352
120°0'0"
Site Area - 817m²
Boat lifting
elec Zone - Low Density Residential
telstra device (8.5x3.0m) Precinct - Nil
proposed
Overlays - Acid Sulphate Soils
mh - Flood Hazard
drive
- Coastal Hazard
jetties
20.415m
Existing jetty to
300°0'0"
be removed
Existing
revetment wall
shorehaven
boundary
Projected
20.415m
9760 from boundary
5"
198°25'4
)
(40.831m
wm
wm
signatures
owner/s
site plan
1 1 : 200
builder
DESIGNER CHECKER WIND CATEGORY CLIENT PROJECT DRAWING NAME SHEET NO REV PROJECT NO
No 13 GODWIN PLACE . PELICAN WATERS . QLD . 4551
0409 612 231 | WWW.KUNKELBUILDINGDESIGN.COM.AU N ORT
H SDK SDK N3 MAX & DEBBIE BROUGHTON NEW JETTY
No. 117 SHOREHAVEN DRIVE, NOOSAVILLE Q 4566
SITE PLAN 01
SHEETS IN SET
A 26.005
SCALE
A3
QBCC Lic No 1136721 REV DATE DRAWN ISSUE
A 02/04/26 SDK CONSTRUCTION ISSUE Lot 683 ON RP897352 2 1 : 200
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Any dimensions not nominated must be referred to the Designer for confirmation. The information contained within this document is the copyright of the Designer. Use or copying in whole or part without the written permission of the Designer constitutes an infringement of copyright. Minimum Design Standards: To be in accordance with current National Construction Code (NCC), Queensland Development Code (QDC), AS/NZS Standards, Building Regulations, Local Government Planning Scheme & Policies
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the original